ODT Export
 

Templates

The list of templates is available in this page, simply scroll down. For additional supported items to monitor navigate the left hand menu to Templates or HowTo.

The templates can be created and loaded into Zabbix using standard Import/Export functionality built-in since Zabbix 1.3.x (pre 1.4). A template may contain information about:

  • items
  • triggers
  • applications
  • custom graphs

Template guidelines

Template should strive to be both unspecific and having wide coverage of metrics, supported by the os, service or device in question. On the other hand, logically separated parts should be split in separate templates - for example, throwing in MySQL monitoring in Linux template is undesirable, as not everybody will be running it. Same goes for most other services like NTP, Bind etc.

Item intervals should be set to relatively large values - it's better to have new user reduce them than start with ridiculously low intervals.

Template page layout

Each template should be uploaded as an XML file and added to the appropriate table. If you want to write detailed monitoring description that would reference this template, place it in the howto section, then link back to the template.

If you want to describe the template only, place it as a subpage in Templates section and name it as the template itself, without the xml extension.

Additional data that could be added to template tables, open for discussion:

  • Author information. Useful for posterity and for contacting author.
  • Version number/last updated - or both? Could be useful for eventual integration in some template management.

Also it might be worth adding vendor column to the tables to make some of them easier to use.

Templates

1 Network devices

Various network devices like switches, routers and firewalls.

NameItemsTriggersApplicationsGraphsZabbix versionsDetail
AgentSNMPIPMISimple 1.61.8
ActivePassive
3Com 3824 Y Y Y Detail
3Com 4200 Y Y Y
3Com 4400 Y Y Y Detail
3Com 4500 Y Y Y Detail
3Com 4500_v2 Y Y Y
Cisco 2950g Y Y 48 port switch - Items (In/Out interface traffic, uptime, cpu & memory utilization …) and Triggers by duBeN
Cisco 2960 Y Y 24 Port 10/100, 2 port Gigabit switch, in/out graphs for every port
Cisco 2960G Y Y 24 port gigabit switch, in/out graphs for every port.
Cisco 2960 48TT Y Y Y48 port gigabit switch, in/out graphs for every port and vlan. Both bps and pps.
Cisco 3560 Y Y Y 48-Port Gigabit Switch. 4 Uplink. Triggers for CPU/Fan/Temp. Graphs for Ports.
Cisco 3750-48TS Y Y Y Double Stack. 96 port 10/100, 8 port GigaBit, in/out graphs for every port, trigger for uptime
Cisco 837 Y Y Router. Monitoring Physical interfaces, in/out graphs for ATM0.
Cisco 877 Y Y Router. Monitoring Physical interfaces, in/out graphs for ATM0.
Cisco 7206 Y Y Y Router. 3 port GigaBit. Items (In/Out interface traffic, uptime, cpu & memory utilization, temperatures …) Triggers and Graphs by duBeN
Netscreen 25 Y Y Y SNMPv1
Juniper Netscreen SSG-140
Juniper ISG-2000
Barracuda Spam Firewall Config file and Instructions; User parameters with curl
Cisco PIX
Cisco PIX 515E Y Y Y 6 FastEthernet interfaces. Graphs for all interfaces, IO and Processor memory, CPU utilisation and concurrent connections. Triggers for uptime and interface status)
Cisco VPN3000 Y Y Y VPN Concentrator with 3 NIC's .in/out graphs for every port and graph of number of active VPN sessions. Triggers for interface state and uptime.
Dell Powerconnect 5224 Y Y Y Switch (24 port 10/100Mbit). I/O graphs for all interfaces, triggers for up/down status of interface 23 and 24 (used as uplink).
Dell Powerconnect 5324 Y Y Y Switch (24 port 10/100/1000Mbit). I/O graphs for all interfaces, triggers for up/down status of interface 21 and 22 (used as uplink).
Infinet R5000 Wireless Router (RMA version, Base Station)
Infinet R5000 Wireless Router(RMA version, Abonent Station)
Cisco Call Manager CCM - Cisco IP-telephony PBX. Monitor active calls, load etc.
Cisco 5350 Cisco IP-telephony gateway from PSTN(E1) to IP-telephony(H.323). Monitor E1 utilization, load etc.
Cisco 6509 Cisco high performance router-switch. (50 Gig - interfaces CPU others).
Dlink 3526 Switch. (50 - interfaces CPU (special oid) others).
Cisco Guard High performance DDOS attack defencer. (1 - template for ZONE(RX and FWD), CPU and others).
Cisco switch 24xeth+2xGb Uses dynamic SNMP indexes for 24 x FastEthernet + 2 x GigabitEthernet, should work on any model with these interfaces. Inc triggers/graph
Cisco switch 48xeth+2xGb Uses dynamic SNMP indexes for 48 x FastEthernet + 2 x GigabitEthernet, should work on any model with these interfaces. Inc triggers/graph
Cisco switch 24xGb Uses dynamic SNMP indexes for 24 x GigabitEthernet, should work on any model with these interfaces. Inc triggers/graph
Cisco 6509 CPU/health (blades)/temperature etc - take care to disable blades not in the chasis
Cisco 6509 - WS-C6748 blade Made for module1, use search/replace to make template for other blades
Cisco 6509 - WS-C6704-10G blade Made for module1, use search/replace to make template for other blades
Cisco 6509 - SUP720 BXL Made for module5/6, use search/replace to make template for other blades
Cisco 6509 - VS-S720-10G Supervisor. Made for module5/6, use search/replace to make template for other blades
Cisco 6509 special flow We used this one when we ran into netflow trouble, ajust as needed.
Mitel 3300 PBX Alarm status
HP Procurve Y 51 ports (interface plus internal), in/out graphs for every port
Zyxel P-660H - ADSL Router Y Y Y YUptime, inbound/outbound rates and discards/errors. ADSL connect rate sadly is only reported for upstream, not downstream.
  • Download Netapp Fabric Metro Cluster, Ontap 7.2.3, items and graphs of the FC switches (brocade 3800). (based on a FAS 3020, thanks to a common OS it should work everywhere)

2 Power devices

Electricity related devices like UPSes, power switches etc.

NameItemsTriggersApplicationsGraphsZabbix versionsDetail
AgentSNMPIPMISimple 1.61.8
ActivePassive
APC Automatic Transfer Switch
APC Battery Backup Unit Requires network management card in APC unit.
APC Smart UPS
ZIP
Requires the check_acp_ups.sh shell script as well as the apcupsd daemon.
APC Symmetra PX40 Based on Powernet MIB v389
APC Metered PDU Power Distribution Unit. Monitoring Load on Phase. 2 template for 2 and 3 Banks.
APC Metered PDU Updated + Power Distribution Unit. Monitoring Load on Phase. 2 template for 2 and 3 Banks. This is updated version to work with devices that also measure totals. 3 Banks version is untested. This is based on above templete by another author.
APC Switched PDU Power Distribution Unit. Monitoring Load on Phase. 2 template for 2 and 3 Banks.
Liebert NX UPS + ++ +?Load, voltage and aperage of 3 lines monitored
Eaton Powerware 9390 UPS + +++ +Eaton Powerware 9390 UPS. Russian items description, graphs names and application, but SNMP keys in English. Input, output, load, battery, external probe, UPS state.

3 Misc

Miscellaneous devices devices that do not fit in other device categories.

NameItemsTriggersApplicationsGraphsZabbix versionsDetail
AgentSNMPIPMISimple 1.61.8
ActivePassive
Barix Exstreamer 100 For Streaming Client Firmware, http://www.barix.com
Barix Instreamer 100 For Default Firmware, http://www.barix.com
APC InRow Air-conditioner. Monitoring temperature and air flow.
WeatherGoose II X X X X X XAn environmental monitor from “IT Watchdogs”. Uses Numeric OID's, MIB installation is not needed. Sample trigger for overheat scenario is included.
EnviroMux Mini EnviroMux Mini. Monitoring temperature Humidity and Dry Contact.

4 Applications

Software packages.

NameItemsTriggersApplicationsGraphsZabbix versionsDetail
AgentSNMPIPMISimple 1.61.8
ActivePassive
Tomcat 5.x.x and 6.x.x Uses Zapcat library. Details
Hibernate O/R mapper Uses Zapcat library. Details
Java 1.5.x and 1.6.x Uses Zapcat library. Details
Lotus Domino SNMP, Beta. By Diorgenes Mello
Microsoft Exchange 2003 Should be okay for 2000 as well
Microsoft Exchange 2007
Microsoft SQL Server Based on SQL 2005 but most things will work on 2000
Interwoven Worksite Server v8.x Document Management System
Barco Control Rooms RC Agent RCS-3110 + + +Wall 2*4. Status, temperature, voltage, brightness, fan, dimmer, etc.

5 Printers

NameItemsTriggersApplicationsGraphsZabbix versionsDetail
AgentSNMPIPMISimple 1.61.8
ActivePassive
Epson AcuLaser C1100 Y AL-C1100 - colour laser printer. Triggers for toner levels and photoconductor unit.
HP Color LaserJet With modifications also for LaserJets without Color

6 Hardware

Hardware like servers, racks etc

NameItemsTriggersApplicationsGraphsZabbix versionsDetail
AgentSNMPIPMISimple 1.61.8
ActivePassive
IBM Director agent status Y IBM Director agent status. Template communicates with IBM Director agent via SNMP. Monitors hardware status of IBM servers.
Dell 2900 and 2950 Temperature and fans Dell 2900 and 2950 Temperature and fans with ipmitool and perl script, see dell
Dell Open Manage Status Monitors status of various hardware parts. Helpful to setup a Value Map ahead of time called “Dell Open Manage System Status” with the values of: 1 → other 2 → unknown 3 → ok 4 → nonCritical 5 → critical 6 → nonRecoverable
Dell PowerEdge Chassis Temperature Details
HP Insight Management Status Based on the Dell Open Manage template I built one for the HP/Compaq Management Agents. Mapping for HP Insight System Status: 1 → other 2 → ok 3 → degraded 4 → failed
LSI / Symbios MegaRAID RAID controller Y YY Y see: the zabbix forum or my site

7 Operating systems

Various monitoring of metrics for operating systems and bundled basic software.

NameItemsTriggersApplicationsGraphsZabbix versionsDetail
AgentSNMPIPMISimple 1.61.8
ActivePassive
Linux firewall Based on iptstate. You have to add zabbix_agentd.conf to your zabbix_agentd.conf file on the firewall. (Not SNMP)
pfSense gateway Y pfSense gateway
Microsoft Windows Eventlog Details

Applications

Operating Systems

SNMP Devices

Other templates

Please add new templates in the tables above.

 
templates/start.txt · Last modified: 2011/10/21 15:44 by bloemkool
 
Except where otherwise noted, content on this wiki is licensed under the following license:CC Attribution-Noncommercial-Share Alike 3.0 Unported
Recent changes RSS feed Donate Powered by PHP Valid XHTML 1.0 Valid CSS Driven by DokuWiki