The list of templates is available in this page, simply scroll down. For additional supported items to monitor navigate the left hand menu to Templates or HowTo.
The templates can be created and loaded into Zabbix using standard Import/Export functionality built-in since Zabbix 1.3.x (pre 1.4). A template may contain information about:
Template should strive to be both unspecific and having wide coverage of metrics, supported by the os, service or device in question. On the other hand, logically separated parts should be split in separate templates - for example, throwing in MySQL monitoring in Linux template is undesirable, as not everybody will be running it. Same goes for most other services like NTP, Bind etc.
Item intervals should be set to relatively large values - it's better to have new user reduce them than start with ridiculously low intervals.
Each template should be uploaded as an XML file and added to the appropriate table. If you want to write detailed monitoring description that would reference this template, place it in the howto section, then link back to the template.
If you want to describe the template only, place it as a subpage in Templates section and name it as the template itself, without the xml extension.
Additional data that could be added to template tables, open for discussion:
Also it might be worth adding vendor column to the tables to make some of them easier to use.
Various network devices like switches, routers and firewalls.
| Name | Items | Triggers | Applications | Graphs | Zabbix versions | Detail | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Agent | SNMP | IPMI | Simple | 1.6 | 1.8 | ||||||
| Active | Passive | ||||||||||
| 3Com 3824 | Y | Y | Y | Detail | |||||||
| 3Com 4200 | Y | Y | Y | ||||||||
| 3Com 4400 | Y | Y | Y | Detail | |||||||
| 3Com 4500 | Y | Y | Y | Detail | |||||||
| 3Com 4500_v2 | Y | Y | Y | ||||||||
| Cisco 2950g | Y | Y | 48 port switch - Items (In/Out interface traffic, uptime, cpu & memory utilization …) and Triggers by duBeN | ||||||||
| Cisco 2960 | Y | Y | 24 Port 10/100, 2 port Gigabit switch, in/out graphs for every port | ||||||||
| Cisco 2960G | Y | Y | 24 port gigabit switch, in/out graphs for every port. | ||||||||
| Cisco 2960 48TT | Y | Y | Y | 48 port gigabit switch, in/out graphs for every port and vlan. Both bps and pps. | |||||||
| Cisco 3560 | Y | Y | Y | 48-Port Gigabit Switch. 4 Uplink. Triggers for CPU/Fan/Temp. Graphs for Ports. | |||||||
| Cisco 3750-48TS | Y | Y | Y | Double Stack. 96 port 10/100, 8 port GigaBit, in/out graphs for every port, trigger for uptime | |||||||
| Cisco 837 | Y | Y | Router. Monitoring Physical interfaces, in/out graphs for ATM0. | ||||||||
| Cisco 877 | Y | Y | Router. Monitoring Physical interfaces, in/out graphs for ATM0. | ||||||||
| Cisco 7206 | Y | Y | Y | Router. 3 port GigaBit. Items (In/Out interface traffic, uptime, cpu & memory utilization, temperatures …) Triggers and Graphs by duBeN | |||||||
| Netscreen 25 | Y | Y | Y | SNMPv1 | |||||||
| Juniper Netscreen SSG-140 | |||||||||||
| Juniper ISG-2000 | |||||||||||
| Barracuda Spam Firewall | Config file and Instructions; User parameters with curl | ||||||||||
| Cisco PIX | |||||||||||
| Cisco PIX 515E | Y | Y | Y | 6 FastEthernet interfaces. Graphs for all interfaces, IO and Processor memory, CPU utilisation and concurrent connections. Triggers for uptime and interface status) | |||||||
| Cisco VPN3000 | Y | Y | Y | VPN Concentrator with 3 NIC's .in/out graphs for every port and graph of number of active VPN sessions. Triggers for interface state and uptime. | |||||||
| Dell Powerconnect 5224 | Y | Y | Y | Switch (24 port 10/100Mbit). I/O graphs for all interfaces, triggers for up/down status of interface 23 and 24 (used as uplink). | |||||||
| Dell Powerconnect 5324 | Y | Y | Y | Switch (24 port 10/100/1000Mbit). I/O graphs for all interfaces, triggers for up/down status of interface 21 and 22 (used as uplink). | |||||||
| Infinet R5000 | Wireless Router (RMA version, Base Station) | ||||||||||
| Infinet R5000 | Wireless Router(RMA version, Abonent Station) | ||||||||||
| Cisco Call Manager | CCM - Cisco IP-telephony PBX. Monitor active calls, load etc. | ||||||||||
| Cisco 5350 | Cisco IP-telephony gateway from PSTN(E1) to IP-telephony(H.323). Monitor E1 utilization, load etc. | ||||||||||
| Cisco 6509 | Cisco high performance router-switch. (50 Gig - interfaces CPU others). | ||||||||||
| Dlink 3526 | Switch. (50 - interfaces CPU (special oid) others). | ||||||||||
| Cisco Guard | High performance DDOS attack defencer. (1 - template for ZONE(RX and FWD), CPU and others). | ||||||||||
| Cisco switch 24xeth+2xGb | Uses dynamic SNMP indexes for 24 x FastEthernet + 2 x GigabitEthernet, should work on any model with these interfaces. Inc triggers/graph | ||||||||||
| Cisco switch 48xeth+2xGb | Uses dynamic SNMP indexes for 48 x FastEthernet + 2 x GigabitEthernet, should work on any model with these interfaces. Inc triggers/graph | ||||||||||
| Cisco switch 24xGb | Uses dynamic SNMP indexes for 24 x GigabitEthernet, should work on any model with these interfaces. Inc triggers/graph | ||||||||||
| Cisco 6509 | CPU/health (blades)/temperature etc - take care to disable blades not in the chasis | ||||||||||
| Cisco 6509 - WS-C6748 blade | Made for module1, use search/replace to make template for other blades | ||||||||||
| Cisco 6509 - WS-C6704-10G blade | Made for module1, use search/replace to make template for other blades | ||||||||||
| Cisco 6509 - SUP720 BXL | Made for module5/6, use search/replace to make template for other blades | ||||||||||
| Cisco 6509 - VS-S720-10G | Supervisor. Made for module5/6, use search/replace to make template for other blades | ||||||||||
| Cisco 6509 special flow | We used this one when we ran into netflow trouble, ajust as needed. | ||||||||||
| Mitel 3300 PBX | Alarm status | ||||||||||
| HP Procurve | Y | 51 ports (interface plus internal), in/out graphs for every port | |||||||||
| Zyxel P-660H - ADSL Router | Y | Y | Y | Y | Uptime, inbound/outbound rates and discards/errors. ADSL connect rate sadly is only reported for upstream, not downstream. | ||||||
Electricity related devices like UPSes, power switches etc.
| Name | Items | Triggers | Applications | Graphs | Zabbix versions | Detail | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Agent | SNMP | IPMI | Simple | 1.6 | 1.8 | ||||||
| Active | Passive | ||||||||||
| APC Automatic Transfer Switch | |||||||||||
| APC Battery Backup Unit | Requires network management card in APC unit. | ||||||||||
| APC Smart UPS ZIP | Requires the check_acp_ups.sh shell script as well as the apcupsd daemon. | ||||||||||
| APC Symmetra PX40 | Based on Powernet MIB v389 | ||||||||||
| APC Metered PDU | Power Distribution Unit. Monitoring Load on Phase. 2 template for 2 and 3 Banks. | ||||||||||
| APC Metered PDU Updated | + | Power Distribution Unit. Monitoring Load on Phase. 2 template for 2 and 3 Banks. This is updated version to work with devices that also measure totals. 3 Banks version is untested. This is based on above templete by another author. | |||||||||
| APC Switched PDU | Power Distribution Unit. Monitoring Load on Phase. 2 template for 2 and 3 Banks. | ||||||||||
| Liebert NX UPS | + | + | + | + | ? | Load, voltage and aperage of 3 lines monitored | |||||
| Eaton Powerware 9390 UPS | + | + | + | + | + | Eaton Powerware 9390 UPS. Russian items description, graphs names and application, but SNMP keys in English. Input, output, load, battery, external probe, UPS state. | |||||
Miscellaneous devices devices that do not fit in other device categories.
| Name | Items | Triggers | Applications | Graphs | Zabbix versions | Detail | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Agent | SNMP | IPMI | Simple | 1.6 | 1.8 | ||||||
| Active | Passive | ||||||||||
| Barix Exstreamer 100 | For Streaming Client Firmware, http://www.barix.com | ||||||||||
| Barix Instreamer 100 | For Default Firmware, http://www.barix.com | ||||||||||
| APC InRow | Air-conditioner. Monitoring temperature and air flow. | ||||||||||
| WeatherGoose II | X | X | X | X | X | X | An environmental monitor from “IT Watchdogs”. Uses Numeric OID's, MIB installation is not needed. Sample trigger for overheat scenario is included. | ||||
| EnviroMux Mini | EnviroMux Mini. Monitoring temperature Humidity and Dry Contact. | ||||||||||
Software packages.
| Name | Items | Triggers | Applications | Graphs | Zabbix versions | Detail | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Agent | SNMP | IPMI | Simple | 1.6 | 1.8 | ||||||
| Active | Passive | ||||||||||
| Tomcat 5.x.x and 6.x.x | Uses Zapcat library. Details | ||||||||||
| Hibernate O/R mapper | Uses Zapcat library. Details | ||||||||||
| Java 1.5.x and 1.6.x | Uses Zapcat library. Details | ||||||||||
| Lotus Domino | SNMP, Beta. By Diorgenes Mello | ||||||||||
| Microsoft Exchange 2003 | Should be okay for 2000 as well | ||||||||||
| Microsoft Exchange 2007 | |||||||||||
| Microsoft SQL Server | Based on SQL 2005 but most things will work on 2000 | ||||||||||
| Interwoven Worksite Server v8.x | Document Management System | ||||||||||
| Barco Control Rooms RC Agent RCS-3110 | + | + | + | Wall 2*4. Status, temperature, voltage, brightness, fan, dimmer, etc. | |||||||
| Name | Items | Triggers | Applications | Graphs | Zabbix versions | Detail | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Agent | SNMP | IPMI | Simple | 1.6 | 1.8 | ||||||
| Active | Passive | ||||||||||
| Epson AcuLaser C1100 | Y | AL-C1100 - colour laser printer. Triggers for toner levels and photoconductor unit. | |||||||||
| HP Color LaserJet | With modifications also for LaserJets without Color | ||||||||||
Hardware like servers, racks etc
| Name | Items | Triggers | Applications | Graphs | Zabbix versions | Detail | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Agent | SNMP | IPMI | Simple | 1.6 | 1.8 | ||||||
| Active | Passive | ||||||||||
| IBM Director agent status | Y | IBM Director agent status. Template communicates with IBM Director agent via SNMP. Monitors hardware status of IBM servers. | |||||||||
| Dell 2900 and 2950 Temperature and fans | Dell 2900 and 2950 Temperature and fans with ipmitool and perl script, see dell | ||||||||||
| Dell Open Manage Status | Monitors status of various hardware parts. Helpful to setup a Value Map ahead of time called “Dell Open Manage System Status” with the values of: 1 → other 2 → unknown 3 → ok 4 → nonCritical 5 → critical 6 → nonRecoverable | ||||||||||
| Dell PowerEdge Chassis Temperature | Details | ||||||||||
| HP Insight Management Status | Based on the Dell Open Manage template I built one for the HP/Compaq Management Agents. Mapping for HP Insight System Status: 1 → other 2 → ok 3 → degraded 4 → failed | ||||||||||
| LSI / Symbios MegaRAID RAID controller | Y | Y | Y | Y | see: the zabbix forum or my site | ||||||
Various monitoring of metrics for operating systems and bundled basic software.
| Name | Items | Triggers | Applications | Graphs | Zabbix versions | Detail | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Agent | SNMP | IPMI | Simple | 1.6 | 1.8 | ||||||
| Active | Passive | ||||||||||
| Linux firewall | Based on iptstate. You have to add zabbix_agentd.conf to your zabbix_agentd.conf file on the firewall. (Not SNMP) | ||||||||||
| pfSense gateway | Y | pfSense gateway | |||||||||
| Microsoft Windows Eventlog | Details | ||||||||||