Manufacturer of power supply products designed to use with various electrical appliances. The company`s power supply products are used in personal computers, engineering work stations, file servers, communications and inter networking equipment, enabling customers to get reliable power and physical IT infrastructure.
LLD of Sensors (Currently Temperature and Humidity & Wireless Tempurature and Humidity)Trigger Prototypes for recommended Humidity and Tempurature based on Netbotz configured thresholdsGraph Prototypes for Temperature and Humidity
There is a UPS SNMP template for UPS with rfc-1628 support. Tested with:APC SURTD3000XLI with APC Network Management Card 2 (AP9630)APC SRT3000RMXLI with APC Network Management Card 2 (AP9630)EATON (PowerWare) 9125-6000g with ConnectUPS Web/SNMP Card.
This template is for use with APC InRow Cooling Units. There are 4 Applications, 25 Items, 6 Triggers, and 3 Graphs.Applications:InformationReturn SideSupply SideThresholdsItems:AirflowCondensate Pump Run hoursCooling Demand PowerCooling output PowerCool Set PointDehumidify/OutputDew PointDischarge PressureFan SpeedHumidifier Run HoursHumidify OutputOperating ModeReturn Side:Air TemoSire Temp ThresholdHumudtyHumidity High and Low ThresholdsSuction PressureSuction TempSupply Side:Set PointAir TempAir Temp ThresholdHumiditySystem NameSystem Up TimeTriggersReturn Humidity High and LowReturn Temp Critical and HighSupply Temp HighThe Triggers are formed using the thresholds set by the APC InRow cooling system setup. The values are pulled from the MIB and stored as Item. This was more efficient when developing the triggers for use with multiple Cooling Units.All the Intervals and History values can be changed per your desired use. Thank you for downloading and using this template.
## In English:Template for Zabbix 3.4 and above.Collects and displays information about voltage, current, power, status, temperature, and battery usage.UPS MIB: http://www.oidview.com/mibs/0/UPS-MIB.htmlSoftware SGM Auto-Shutdown V4.1:http://www.apc.com/shop/br/pt/products/Software-SGM-Auto-Shutdown-V4-1-para-Linux-s%C3%B3-Brasil-/P-SFSGM41L?isCurrentSite=trueDashboard Grafana: https://grafana.com/dashboards/3926## Em Português:Template para Zabbix 3.4 ou superior.Coleta e exibe informações da tensão, corrente, potência, status, temperatura e uso da bateria.UPS MIB: http://www.oidview.com/mibs/0/UPS-MIB.htmlSoftware SGM Auto-Shutdown V4.1:http://www.apc.com/shop/br/pt/products/Software-SGM-Auto-Shutdown-V4-1-para-Linux-s%C3%B3-Brasil-/P-SFSGM41L?isCurrentSite=trueDashboard Grafana: https://grafana.com/dashboards/3926## Developed by:Victor Igor ([email protected]), sysadmin;Aécio Pires (http://aeciopires.com), sysadmin.Shared by Dynavideo (http://www.dynavideo.com.br)
APC ATS TemplateModel : AP4423Update APC To the Last Version. otherwise Snmpget wouldnt work fine.
Monitoring APC UPS (without SNMP) through APCUPSd.Russian language.Мониторинг ИБП APC (без SNMP) через APCUPSd.На русском языке.Переменные:ИмяТекущий статусУровень заряда батареиВнутренняя температураНапряжение на входеУровень нагрузкиУровень чувствительностиКоличество переходов на питание от батареи с момента запуска apcupsdПримеры настройки Zabbix agent
universal template for windows APC Agent (APCPBEAgent) PC PowerChute Business Edition Agentfrom eventid logsIn Russian with comments in EnglishAlerts:about switching to battery with event closingwhen switching to a networkon compensation for increasing voltage in the network with the closing of the eventon compensation for undervoltage in the network with the closing of the eventabout disconnecting USB from the UPS with closing the eventabout unstable connection with the UPS with the closing of the event"Battery life threshold exceeded""Battery low"Оповещения :о переключении на батарею с закрытием события при переключении на сетьо компенсации при повышении напряжения в сети с закрытием событияо компенсации при понижении напряжения в сети с закрытием событияоб отключении USB от ИБП с закрытием событияо нестабильном соединение c ИБП с закрытием события "Превышен порог времени работы от батареи""Батарея разряжена"
This template was originaly created for the AP9619 card, but in version 2 now support more UPS´s.Tested on:APC Symmetra PX40 3Phase UPSAPC Smart-UPS VT 20kVA 3Phase UPSSmart-UPS RT 7500 RM XLand more...It gathers input and output values from all three phases. I tried to make it as universal as i could so it can be used with single phase ups´s as well. I have disable some of the items on the template for the reason that my ups didn´t support them, feel free to try them if they are supported by your UPS.Changelog V2:Added more items for single phase ups´s and triggers.thanks,petroska
This template is for situation when you have apcupsd, but cannot install zabbix agent. Tested with Centos 6.x.You have to install apcupsd and configure it, configure ssh access for user by certificate.Provides:Items: model, serial number, number of switching (xfers), name (set in apcupsd config), status (ONLINE and etc), charge level, timeleft.Triggers: minimal timeleft is equal or less then {$APC_SMARTUPS_MINIMAL_TIMELEFT}, status is not ONLINE.Requires macroses:{$UPS_GET_MAININFO_PERIOD} - period of getting model and etc.{$UPS_GET_STATUS_PERIOD} – period of getting status, timeleft, status.{$APC_SMARTUPS_MINIMAL_TIMELEFT} –minimal timeleft for trigger.{$SSH_CONNECT_USERNAME} – user for connecting by ssh.If you have any ideas to make this template better, comment, please.
This template covers basic monitoring with some triggers.I use it on a Windows Server 2016 with PowerChute Business Edition installed.Feel free to modify this template to meet your needs.Configure PowerChute Business Edition to use SNMP v1 with Community "public".The following applications, triggers and items are configured:Applications and ItemsInfoAPC Firmware RevisionAPC ModellAPC Serial NumberBatteryAPC Battery CapacityAPC Battery Replace IndicatorAPC Battery StatusAPC Battery TemperatureAPC Battery VoltageAPC Time on BatteryAPC Time on Battery remainingInputAPC Input FrequencyAPC Input PhaseAPC Input VoltageOutputAPC Output Current (Amperes)APC Output FrequencyAPC Output LoadAPC Output PhaseAPC Output Status (basic)APC Output VoltageDiagnosticsTest Last Diagnostics DateTest Last Diagnostics ResultsTriggersInformation UPS Capacity lower than 90 PercentWarning UPS Capacity lower than 70 PercentAverage UPS Capacity lower than 50 PercentAverage UPS Capacity lower than 30 PercentHigh UPS Capacity lower than 20 PercentDisaster UPS Capacity lower than 10 PercentAverage Test FailedDisaster Remaining Time on Battery is lower than 5 MinutesHigh No Power SourceWarning Load on this APC unit is to highAverage Input Fequency to lowAverage Input Fequency to highInformation Frequency is not 50 HzAverage Battery should be replaced
UPDATE: Uploaded V2 to fix one of the power ratings that was the wrong OID. It was collecting watts incorrectly. All fixed now!This APC Template contains outlet discovery and should work with any managed or switched APC PDU.Contains sane triggers, load status, graphs, etc.Triggers: APC Load State, Load Change, Power Alarm, etc.Items: Basic information (model, name, firmware, etc), Power load/peak/etc, Master States (Enable for older units), All APC value mappings, and much more.Graphs: Load and CurrentOutlet Status (Dynamic Discovery)Please enjoy and vote!
I have created a very detailed template for a Rack Mounted APC PDU. I spent a considerable amount of time digging through the MIB to obtain all the correct OID numbers pertaining to each Item for the PDU to use with SNMP. The template includes:7 Applications:EnviornmentInformationOutletsPeaksPhasesPowerThresholds39 Items for monitoring that range from:7 Items for each phase totaling 21 itemsLoadOverload ThresholdsCurrentPowerVoltageFirmware RevTotal PowerPeak PowerLoad StateRack Temp/Humidity (if the sensors are present)13 TriggersIndividual triggers for each phaseVoltage High and LowLoad State ChangesPower TriggerNear overload and Overload Triggers3 Default GraphsCurrent UsagePhase Power StatusTemp/Humid (If sensors are present)I hope you enjoy using this template as much as I have. You can tweak the Interval and History settings within each item per your needs. I have also included HOSTNAME calls in each Trigger to Identify the host that is causing the Trigger.
The template is a reworked a version of APC PDU New SNMP Template to suit the needs of our AP7953.Contains sane triggers, load status, graphs, etc.The template monitors both load banks, status of the alarms, and changes in the port status (on/off)
LLD of Sensors (Only Temperature and humidity)Trigger Prototypes for recommended 45RH% - 55RH% humidity and 20°C - 24°C TemperatureGraph Prototypes for Temperature and Humidity.Triggers names contain the last value that cause the trigger so you can see the temp/hum in the alert.
I made a simple template for the APC Netbotz AP9340, i currently have 2 (RJ45) temperature sensors connected and retrieving the temp and humidity from both.