Available solutions
Netgear Fastpath by SNMP
Overview
https://kb.netgear.com/24352/MIBs-for-Smart-switches
Requirements
Zabbix version: 8.0 and higher.
Tested versions
This template has been tested on:
- Netgear M5300-28G
Configuration
Zabbix should be configured according to the instructions in the Templates out of the box section.
Setup
Refer to the vendor documentation.
Macros used
| Name | Description | Default |
|---|---|---|
| {$CPU.UTIL.CRIT} | 90 |
|
| {$TEMP_CRIT} | 60 |
|
| {$TEMP_CRIT_LOW} | 5 |
|
| {$TEMP_WARN} | 50 |
|
| {$TEMP_WARN_STATUS} | 2 |
|
| {$TEMP_CRIT_STATUS} | 3 |
|
| {$PSU_CRIT_STATUS:"failed"} | 2 |
|
| {$FAN_CRIT_STATUS:"failed"} | 2 |
|
| {$MEMORY.UTIL.MAX} | 90 |
|
| {$SNMP.TIMEOUT} | Time interval for the SNMP availability trigger. |
5m |
| {$SNMP.UPTIME.WARN} | Uptime threshold above which the "Host has been restarted" problem auto-resolves. |
10m |
| {$ICMP_LOSS_WARN} | Warning threshold of ICMP packet loss in %. |
20 |
| {$ICMP_RESPONSE_TIME_WARN} | Warning threshold of the average ICMP response time in seconds. |
0.15 |
| {$IF.ERRORS.WARN} | Warning threshold of error packet rate. Can be used with interface name as context. |
2 |
| {$IF.UTIL.MAX} | 90 |
|
| {$IFCONTROL} | 1 |
|
| {$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
| {$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFADMINSTATUS.MATCHES} | ^.* |
|
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFDESCR.MATCHES} | .* |
|
| {$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFALIAS.MATCHES} | .* |
|
| {$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFTYPE.MATCHES} | .* |
|
| {$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| CPU utilization | MIB: FASTPATH-SWITCHING-MIB The CPU utilization expressed in %. |
SNMP agent | system.cpu.util[agentSwitchCpuProcessTotalUtilization.0] Preprocessing
|
| Available memory | MIB: FASTPATH-SWITCHING-MIB The total memory freed for utilization. |
SNMP agent | vm.memory.available[agentSwitchCpuProcessMemFree.0] |
| Total memory | MIB: FASTPATH-SWITCHING-MIB The total Memory allocated for the tasks |
SNMP agent | vm.memory.total[agentSwitchCpuProcessMemAvailable.0] |
| Memory utilization | Memory utilization in %. |
Calculated | vm.memory.util[memoryUsedPercentage.0] |
| Operating system | MIB: FASTPATH-SWITCHING-MIB Operating System running on this unit |
SNMP agent | system.sw.os[agentInventoryOperatingSystem.0] Preprocessing
|
| Hardware model name | MIB: FASTPATH-SWITCHING-MIB |
SNMP agent | system.hw.model Preprocessing
|
| Hardware serial number | MIB: FASTPATH-SWITCHING-MIB Serial number of the switch |
SNMP agent | system.hw.serialnumber Preprocessing
|
| Uptime (network) | MIB: SNMPv2-MIB Time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
| Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
| SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
| System location | MIB: SNMPv2-MIB Physical location of the node (e.g., |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
| System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
| System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
| System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
| System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
| SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible values: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
| ICMP ping | The host accessibility by ICMP ping. 0 - ICMP ping fails; 1 - ICMP ping successful. |
Simple check | icmpping |
| ICMP loss | The percentage of lost packets. |
Simple check | icmppingloss |
| ICMP response time | The ICMP ping response time (in seconds). |
Simple check | icmppingsec |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Netgear Fastpath by SNMP/system.cpu.util[agentSwitchCpuProcessTotalUtilization.0],5m)>{$CPU.UTIL.CRIT} |
Warning | |
| Netgear Fastpath: High memory utilization | The system is running out of free memory. |
min(/Netgear Fastpath by SNMP/vm.memory.util[memoryUsedPercentage.0],5m)>{$MEMORY.UTIL.MAX} |
Average | |
| Netgear Fastpath: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#1)<>last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#2) and length(last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0]))>0 |
Info | Manual close: Yes Depends on:
|
| Netgear Fastpath: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#1)<>last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#2) and length(last(/Netgear Fastpath by SNMP/system.hw.serialnumber))>0 |
Info | Manual close: Yes |
| Netgear Fastpath: Host has been restarted | The uptime counter has decreased, which indicates that the host has been restarted. |
(last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and change(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])<0 and last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0],#2)<42949672.96-(lastclock(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])-lastclock(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0],#2))) or (last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and change(/Netgear Fastpath by SNMP/system.net.uptime[sysUpTime.0])<0 and last(/Netgear Fastpath by SNMP/system.net.uptime[sysUpTime.0],#2)<42949672.96-(lastclock(/Netgear Fastpath by SNMP/system.net.uptime[sysUpTime.0])-lastclock(/Netgear Fastpath by SNMP/system.net.uptime[sysUpTime.0],#2))) |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.name,#1)<>last(/Netgear Fastpath by SNMP/system.name,#2) and length(last(/Netgear Fastpath by SNMP/system.name))>0 |
Info | Manual close: Yes |
| Netgear Fastpath: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Netgear Fastpath by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
| Netgear Fastpath: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Netgear Fastpath by SNMP/icmpping,#3)=0 |
High | |
| Netgear Fastpath: High ICMP ping loss | ICMP packets loss detected. |
min(/Netgear Fastpath by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Netgear Fastpath by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
| Netgear Fastpath: High ICMP ping response time | Average ICMP response time is too high. |
avg(/Netgear Fastpath by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable |
SNMP agent | temp.discovery |
Item prototypes for Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Temperature | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The temperature value reported by sensor |
SNMP agent | sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}] |
| #{#SNMPVALUE}: Temperature status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The state of temperature sensor |
SNMP agent | sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}] |
Trigger prototypes for Temperature Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: #{#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_WARN_STATUS} |
Warning | Depends on:
|
| Netgear Fastpath: #{#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS} |
High | |
| Netgear Fastpath: #{#SNMPVALUE}: Temperature is too low | avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average |
LLD rule FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::1.3.6.1.4.1.4526.10.43.1.6.1.1 |
SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Fan status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of fan |
SNMP agent | sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: #{#SNMPVALUE}: Fan is in critical state | Please check the fan unit |
count(/Netgear Fastpath by SNMP/sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"failed\"}")=1 |
Average |
LLD rule PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| PSU Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesPowSupplyIndex |
SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Power supply status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of power supply |
SNMP agent | sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: #{#SNMPVALUE}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Netgear Fastpath by SNMP/sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"failed\"}")=1 |
Average |
LLD rule Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Netgear Fastpath by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Netgear Fastpath by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Netgear Fastpath by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Netgear Fastpath by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums
Vendor and Community integrations are created by third parties and are not verified by Zabbix. Zabbix is not responsible for their functionality or quality.
Zabbix community templates
7 Contributed to the zabbix/community-templates repositoryTemplate for Netgear WG103 access point.Works with Zabbix 2.4.7 and a Netgear WG103 FW 2.2.5.Contains :Basic information such as : FWversion, S/N, APname, MACLAN, MACWLANInterfaces traffic (LAN and WLAN)Wifi profiles namesCurrent users number connected to the AP
Template for Netgear GS110TP using SNMP.Probably needs to be improved (no triggers).Community used is "public"
Template is based on MIB http://www.downloads.netgear.com/files/ReadyNAS/READYNAS-MIB.txt.LLD of disks.It monitors:Disks temperature in Celsius. There is a triggerDisks state. There is triggerVolume state. There is triggerVolume size, free space. There is triggerAnd other.For tuning of a template macros are usedPerhaps works at versions 2.*.
Netgear Fastpath by SNMP
Overview
https://kb.netgear.com/24352/MIBs-for-Smart-switches
Requirements
Zabbix version: 7.4 and higher.
Tested versions
This template has been tested on:
- Netgear M5300-28G
Configuration
Zabbix should be configured according to the instructions in the Templates out of the box section.
Setup
Refer to the vendor documentation.
Macros used
| Name | Description | Default |
|---|---|---|
| {$CPU.UTIL.CRIT} | 90 |
|
| {$TEMP_CRIT} | 60 |
|
| {$TEMP_CRIT_LOW} | 5 |
|
| {$TEMP_WARN} | 50 |
|
| {$TEMP_WARN_STATUS} | 2 |
|
| {$TEMP_CRIT_STATUS} | 3 |
|
| {$PSU_CRIT_STATUS:"failed"} | 2 |
|
| {$FAN_CRIT_STATUS:"failed"} | 2 |
|
| {$MEMORY.UTIL.MAX} | 90 |
|
| {$SNMP.TIMEOUT} | Time interval for the SNMP availability trigger. |
5m |
| {$ICMP_LOSS_WARN} | Warning threshold of ICMP packet loss in %. |
20 |
| {$ICMP_RESPONSE_TIME_WARN} | Warning threshold of the average ICMP response time in seconds. |
0.15 |
| {$IF.ERRORS.WARN} | Warning threshold of error packet rate. Can be used with interface name as context. |
2 |
| {$IF.UTIL.MAX} | 90 |
|
| {$IFCONTROL} | 1 |
|
| {$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
| {$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFADMINSTATUS.MATCHES} | ^.* |
|
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFDESCR.MATCHES} | .* |
|
| {$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFALIAS.MATCHES} | .* |
|
| {$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFTYPE.MATCHES} | .* |
|
| {$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| CPU utilization | MIB: FASTPATH-SWITCHING-MIB The CPU utilization expressed in %. |
SNMP agent | system.cpu.util[agentSwitchCpuProcessTotalUtilization.0] Preprocessing
|
| Available memory | MIB: FASTPATH-SWITCHING-MIB The total memory freed for utilization. |
SNMP agent | vm.memory.available[agentSwitchCpuProcessMemFree.0] |
| Total memory | MIB: FASTPATH-SWITCHING-MIB The total Memory allocated for the tasks |
SNMP agent | vm.memory.total[agentSwitchCpuProcessMemAvailable.0] |
| Memory utilization | Memory utilization in %. |
Calculated | vm.memory.util[memoryUsedPercentage.0] |
| Operating system | MIB: FASTPATH-SWITCHING-MIB Operating System running on this unit |
SNMP agent | system.sw.os[agentInventoryOperatingSystem.0] Preprocessing
|
| Hardware model name | MIB: FASTPATH-SWITCHING-MIB |
SNMP agent | system.hw.model Preprocessing
|
| Hardware serial number | MIB: FASTPATH-SWITCHING-MIB Serial number of the switch |
SNMP agent | system.hw.serialnumber Preprocessing
|
| Uptime (network) | MIB: SNMPv2-MIB Time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
| Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
| SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
| System location | MIB: SNMPv2-MIB Physical location of the node (e.g., |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
| System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
| System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
| System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
| System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
| SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible values: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
| ICMP ping | The host accessibility by ICMP ping. 0 - ICMP ping fails; 1 - ICMP ping successful. |
Simple check | icmpping |
| ICMP loss | The percentage of lost packets. |
Simple check | icmppingloss |
| ICMP response time | The ICMP ping response time (in seconds). |
Simple check | icmppingsec |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Netgear Fastpath by SNMP/system.cpu.util[agentSwitchCpuProcessTotalUtilization.0],5m)>{$CPU.UTIL.CRIT} |
Warning | |
| Netgear Fastpath: High memory utilization | The system is running out of free memory. |
min(/Netgear Fastpath by SNMP/vm.memory.util[memoryUsedPercentage.0],5m)>{$MEMORY.UTIL.MAX} |
Average | |
| Netgear Fastpath: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#1)<>last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#2) and length(last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0]))>0 |
Info | Manual close: Yes Depends on:
|
| Netgear Fastpath: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#1)<>last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#2) and length(last(/Netgear Fastpath by SNMP/system.hw.serialnumber))>0 |
Info | Manual close: Yes |
| Netgear Fastpath: Host has been restarted | Uptime is less than 10 minutes. |
(last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Netgear Fastpath by SNMP/system.net.uptime[sysUpTime.0])<10m) |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.name,#1)<>last(/Netgear Fastpath by SNMP/system.name,#2) and length(last(/Netgear Fastpath by SNMP/system.name))>0 |
Info | Manual close: Yes |
| Netgear Fastpath: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Netgear Fastpath by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
| Netgear Fastpath: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Netgear Fastpath by SNMP/icmpping,#3)=0 |
High | |
| Netgear Fastpath: High ICMP ping loss | ICMP packets loss detected. |
min(/Netgear Fastpath by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Netgear Fastpath by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
| Netgear Fastpath: High ICMP ping response time | Average ICMP response time is too high. |
avg(/Netgear Fastpath by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable |
SNMP agent | temp.discovery |
Item prototypes for Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Temperature | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The temperature value reported by sensor |
SNMP agent | sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}] |
| #{#SNMPVALUE}: Temperature status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The state of temperature sensor |
SNMP agent | sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}] |
Trigger prototypes for Temperature Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: #{#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_WARN_STATUS} |
Warning | Depends on:
|
| Netgear Fastpath: #{#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS} |
High | |
| Netgear Fastpath: #{#SNMPVALUE}: Temperature is too low | avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average |
LLD rule FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::1.3.6.1.4.1.4526.10.43.1.6.1.1 |
SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Fan status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of fan |
SNMP agent | sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: #{#SNMPVALUE}: Fan is in critical state | Please check the fan unit |
count(/Netgear Fastpath by SNMP/sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"failed\"}")=1 |
Average |
LLD rule PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| PSU Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesPowSupplyIndex |
SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Power supply status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of power supply |
SNMP agent | sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: #{#SNMPVALUE}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Netgear Fastpath by SNMP/sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"failed\"}")=1 |
Average |
LLD rule Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Netgear Fastpath by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Netgear Fastpath by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Netgear Fastpath by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Netgear Fastpath by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums
Netgear Fastpath by SNMP
Overview
https://kb.netgear.com/24352/MIBs-for-Smart-switches
Requirements
Zabbix version: 7.2 and higher.
Tested versions
This template has been tested on:
- Netgear M5300-28G
Configuration
Zabbix should be configured according to the instructions in the Templates out of the box section.
Setup
Refer to the vendor documentation.
Macros used
| Name | Description | Default |
|---|---|---|
| {$CPU.UTIL.CRIT} | 90 |
|
| {$TEMP_CRIT} | 60 |
|
| {$TEMP_CRIT_LOW} | 5 |
|
| {$TEMP_WARN} | 50 |
|
| {$TEMP_WARN_STATUS} | 2 |
|
| {$TEMP_CRIT_STATUS} | 3 |
|
| {$PSU_CRIT_STATUS:"failed"} | 2 |
|
| {$FAN_CRIT_STATUS:"failed"} | 2 |
|
| {$MEMORY.UTIL.MAX} | 90 |
|
| {$SNMP.TIMEOUT} | Time interval for the SNMP availability trigger. |
5m |
| {$ICMP_LOSS_WARN} | Warning threshold of ICMP packet loss in %. |
20 |
| {$ICMP_RESPONSE_TIME_WARN} | Warning threshold of the average ICMP response time in seconds. |
0.15 |
| {$IF.ERRORS.WARN} | Warning threshold of error packet rate. Can be used with interface name as context. |
2 |
| {$IF.UTIL.MAX} | 90 |
|
| {$IFCONTROL} | 1 |
|
| {$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
| {$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFADMINSTATUS.MATCHES} | ^.* |
|
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFDESCR.MATCHES} | .* |
|
| {$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFALIAS.MATCHES} | .* |
|
| {$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFTYPE.MATCHES} | .* |
|
| {$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| CPU utilization | MIB: FASTPATH-SWITCHING-MIB The CPU utilization expressed in %. |
SNMP agent | system.cpu.util[agentSwitchCpuProcessTotalUtilization.0] Preprocessing
|
| Available memory | MIB: FASTPATH-SWITCHING-MIB The total memory freed for utilization. |
SNMP agent | vm.memory.available[agentSwitchCpuProcessMemFree.0] |
| Total memory | MIB: FASTPATH-SWITCHING-MIB The total Memory allocated for the tasks |
SNMP agent | vm.memory.total[agentSwitchCpuProcessMemAvailable.0] |
| Memory utilization | Memory utilization in %. |
Calculated | vm.memory.util[memoryUsedPercentage.0] |
| Operating system | MIB: FASTPATH-SWITCHING-MIB Operating System running on this unit |
SNMP agent | system.sw.os[agentInventoryOperatingSystem.0] Preprocessing
|
| Hardware model name | MIB: FASTPATH-SWITCHING-MIB |
SNMP agent | system.hw.model Preprocessing
|
| Hardware serial number | MIB: FASTPATH-SWITCHING-MIB Serial number of the switch |
SNMP agent | system.hw.serialnumber Preprocessing
|
| Uptime (network) | MIB: SNMPv2-MIB Time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
| Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
| SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
| System location | MIB: SNMPv2-MIB Physical location of the node (e.g., |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
| System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
| System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
| System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
| System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
| SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible values: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
| ICMP ping | Simple check | icmpping | |
| ICMP loss | Simple check | icmppingloss | |
| ICMP response time | Simple check | icmppingsec |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Netgear Fastpath by SNMP/system.cpu.util[agentSwitchCpuProcessTotalUtilization.0],5m)>{$CPU.UTIL.CRIT} |
Warning | |
| Netgear Fastpath: High memory utilization | The system is running out of free memory. |
min(/Netgear Fastpath by SNMP/vm.memory.util[memoryUsedPercentage.0],5m)>{$MEMORY.UTIL.MAX} |
Average | |
| Netgear Fastpath: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#1)<>last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#2) and length(last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0]))>0 |
Info | Manual close: Yes Depends on:
|
| Netgear Fastpath: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#1)<>last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#2) and length(last(/Netgear Fastpath by SNMP/system.hw.serialnumber))>0 |
Info | Manual close: Yes |
| Netgear Fastpath: Host has been restarted | Uptime is less than 10 minutes. |
(last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Netgear Fastpath by SNMP/system.net.uptime[sysUpTime.0])<10m) |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.name,#1)<>last(/Netgear Fastpath by SNMP/system.name,#2) and length(last(/Netgear Fastpath by SNMP/system.name))>0 |
Info | Manual close: Yes |
| Netgear Fastpath: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Netgear Fastpath by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
| Netgear Fastpath: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Netgear Fastpath by SNMP/icmpping,#3)=0 |
High | |
| Netgear Fastpath: High ICMP ping loss | min(/Netgear Fastpath by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Netgear Fastpath by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
|
| Netgear Fastpath: High ICMP ping response time | Average ICMP response time is too high. |
avg(/Netgear Fastpath by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable |
SNMP agent | temp.discovery |
Item prototypes for Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Temperature | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The temperature value reported by sensor |
SNMP agent | sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}] |
| #{#SNMPVALUE}: Temperature status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The state of temperature sensor |
SNMP agent | sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}] |
Trigger prototypes for Temperature Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: #{#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_WARN_STATUS} |
Warning | Depends on:
|
| Netgear Fastpath: #{#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS} |
High | |
| Netgear Fastpath: #{#SNMPVALUE}: Temperature is too low | avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average |
LLD rule FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::1.3.6.1.4.1.4526.10.43.1.6.1.1 |
SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Fan status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of fan |
SNMP agent | sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: #{#SNMPVALUE}: Fan is in critical state | Please check the fan unit |
count(/Netgear Fastpath by SNMP/sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"failed\"}")=1 |
Average |
LLD rule PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| PSU Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesPowSupplyIndex |
SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Power supply status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of power supply |
SNMP agent | sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: #{#SNMPVALUE}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Netgear Fastpath by SNMP/sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"failed\"}")=1 |
Average |
LLD rule Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Netgear Fastpath by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Netgear Fastpath by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Netgear Fastpath by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Netgear Fastpath by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums
Netgear Fastpath by SNMP
Overview
https://kb.netgear.com/24352/MIBs-for-Smart-switches
Requirements
Zabbix version: 7.0 and higher.
Tested versions
This template has been tested on:
- Netgear M5300-28G
Configuration
Zabbix should be configured according to the instructions in the Templates out of the box section.
Setup
Refer to the vendor documentation.
Macros used
| Name | Description | Default |
|---|---|---|
| {$CPU.UTIL.CRIT} | 90 |
|
| {$TEMP_CRIT} | 60 |
|
| {$TEMP_CRIT_LOW} | 5 |
|
| {$TEMP_WARN} | 50 |
|
| {$TEMP_WARN_STATUS} | 2 |
|
| {$TEMP_CRIT_STATUS} | 3 |
|
| {$PSU_CRIT_STATUS:"failed"} | 2 |
|
| {$FAN_CRIT_STATUS:"failed"} | 2 |
|
| {$MEMORY.UTIL.MAX} | 90 |
|
| {$SNMP.TIMEOUT} | Time interval for the SNMP availability trigger. |
5m |
| {$ICMP_LOSS_WARN} | Warning threshold of ICMP packet loss in %. |
20 |
| {$ICMP_RESPONSE_TIME_WARN} | Warning threshold of the average ICMP response time in seconds. |
0.15 |
| {$IF.ERRORS.WARN} | Warning threshold of error packet rate. Can be used with interface name as context. |
2 |
| {$IF.UTIL.MAX} | 90 |
|
| {$IFCONTROL} | 1 |
|
| {$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
| {$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFADMINSTATUS.MATCHES} | ^.* |
|
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFDESCR.MATCHES} | .* |
|
| {$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFALIAS.MATCHES} | .* |
|
| {$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFTYPE.MATCHES} | .* |
|
| {$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| CPU utilization | MIB: FASTPATH-SWITCHING-MIB The CPU utilization expressed in %. |
SNMP agent | system.cpu.util[agentSwitchCpuProcessTotalUtilization.0] Preprocessing
|
| Available memory | MIB: FASTPATH-SWITCHING-MIB The total memory freed for utilization. |
SNMP agent | vm.memory.available[agentSwitchCpuProcessMemFree.0] |
| Total memory | MIB: FASTPATH-SWITCHING-MIB The total Memory allocated for the tasks |
SNMP agent | vm.memory.total[agentSwitchCpuProcessMemAvailable.0] |
| Memory utilization | Memory utilization in %. |
Calculated | vm.memory.util[memoryUsedPercentage.0] |
| Operating system | MIB: FASTPATH-SWITCHING-MIB Operating System running on this unit |
SNMP agent | system.sw.os[agentInventoryOperatingSystem.0] Preprocessing
|
| Hardware model name | MIB: FASTPATH-SWITCHING-MIB |
SNMP agent | system.hw.model Preprocessing
|
| Hardware serial number | MIB: FASTPATH-SWITCHING-MIB Serial number of the switch |
SNMP agent | system.hw.serialnumber Preprocessing
|
| Uptime (network) | MIB: SNMPv2-MIB Time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
| Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
| SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
| System location | MIB: SNMPv2-MIB Physical location of the node (e.g., |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
| System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
| System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
| System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
| System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
| SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible values: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
| ICMP ping | The host accessibility by ICMP ping. 0 - ICMP ping fails; 1 - ICMP ping successful. |
Simple check | icmpping |
| ICMP loss | The percentage of lost packets. |
Simple check | icmppingloss |
| ICMP response time | The ICMP ping response time (in seconds). |
Simple check | icmppingsec |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Netgear Fastpath by SNMP/system.cpu.util[agentSwitchCpuProcessTotalUtilization.0],5m)>{$CPU.UTIL.CRIT} |
Warning | |
| Netgear Fastpath: High memory utilization | The system is running out of free memory. |
min(/Netgear Fastpath by SNMP/vm.memory.util[memoryUsedPercentage.0],5m)>{$MEMORY.UTIL.MAX} |
Average | |
| Netgear Fastpath: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#1)<>last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#2) and length(last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0]))>0 |
Info | Manual close: Yes Depends on:
|
| Netgear Fastpath: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#1)<>last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#2) and length(last(/Netgear Fastpath by SNMP/system.hw.serialnumber))>0 |
Info | Manual close: Yes |
| Netgear Fastpath: Host has been restarted | Uptime is less than 10 minutes. |
(last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Netgear Fastpath by SNMP/system.net.uptime[sysUpTime.0])<10m) |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.name,#1)<>last(/Netgear Fastpath by SNMP/system.name,#2) and length(last(/Netgear Fastpath by SNMP/system.name))>0 |
Info | Manual close: Yes |
| Netgear Fastpath: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Netgear Fastpath by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
| Netgear Fastpath: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Netgear Fastpath by SNMP/icmpping,#3)=0 |
High | |
| Netgear Fastpath: High ICMP ping loss | ICMP packets loss detected. |
min(/Netgear Fastpath by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Netgear Fastpath by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
| Netgear Fastpath: High ICMP ping response time | Average ICMP response time is too high. |
avg(/Netgear Fastpath by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable |
SNMP agent | temp.discovery |
Item prototypes for Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Temperature | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The temperature value reported by sensor |
SNMP agent | sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}] |
| #{#SNMPVALUE}: Temperature status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The state of temperature sensor |
SNMP agent | sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}] |
Trigger prototypes for Temperature Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: #{#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_WARN_STATUS} |
Warning | Depends on:
|
| Netgear Fastpath: #{#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS} |
High | |
| Netgear Fastpath: #{#SNMPVALUE}: Temperature is too low | avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average |
LLD rule FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::1.3.6.1.4.1.4526.10.43.1.6.1.1 |
SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Fan status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of fan |
SNMP agent | sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: #{#SNMPVALUE}: Fan is in critical state | Please check the fan unit |
count(/Netgear Fastpath by SNMP/sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"failed\"}")=1 |
Average |
LLD rule PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| PSU Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesPowSupplyIndex |
SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Power supply status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of power supply |
SNMP agent | sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: #{#SNMPVALUE}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Netgear Fastpath by SNMP/sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"failed\"}")=1 |
Average |
LLD rule Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Netgear Fastpath by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Netgear Fastpath by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Netgear Fastpath by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Netgear Fastpath by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums
Netgear Fastpath by SNMP
Overview
https://kb.netgear.com/24352/MIBs-for-Smart-switches
Requirements
Zabbix version: 6.4 and higher.
Tested versions
This template has been tested on:
- Netgear M5300-28G
Configuration
Zabbix should be configured according to the instructions in the Templates out of the box section.
Setup
Refer to the vendor documentation.
Macros used
| Name | Description | Default |
|---|---|---|
| {$CPU.UTIL.CRIT} | 90 |
|
| {$TEMP_CRIT} | 60 |
|
| {$TEMP_CRIT_LOW} | 5 |
|
| {$TEMP_WARN} | 50 |
|
| {$TEMP_WARN_STATUS} | 2 |
|
| {$TEMP_CRIT_STATUS} | 3 |
|
| {$PSU_CRIT_STATUS:"failed"} | 2 |
|
| {$FAN_CRIT_STATUS:"failed"} | 2 |
|
| {$MEMORY.UTIL.MAX} | 90 |
|
| {$SNMP.TIMEOUT} | 5m |
|
| {$ICMP_LOSS_WARN} | 20 |
|
| {$ICMP_RESPONSE_TIME_WARN} | 0.15 |
|
| {$IF.ERRORS.WARN} | 2 |
|
| {$IF.UTIL.MAX} | 90 |
|
| {$IFCONTROL} | 1 |
|
| {$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
| {$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFADMINSTATUS.MATCHES} | ^.* |
|
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFDESCR.MATCHES} | .* |
|
| {$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFALIAS.MATCHES} | .* |
|
| {$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFTYPE.MATCHES} | .* |
|
| {$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Netgear Fastpath: CPU utilization | MIB: FASTPATH-SWITCHING-MIB The CPU utilization expressed in %. |
SNMP agent | system.cpu.util[agentSwitchCpuProcessTotalUtilization.0] Preprocessing
|
| Netgear Fastpath: Available memory | MIB: FASTPATH-SWITCHING-MIB The total memory freed for utilization. |
SNMP agent | vm.memory.available[agentSwitchCpuProcessMemFree.0] |
| Netgear Fastpath: Total memory | MIB: FASTPATH-SWITCHING-MIB The total Memory allocated for the tasks |
SNMP agent | vm.memory.total[agentSwitchCpuProcessMemAvailable.0] |
| Netgear Fastpath: Memory utilization | Memory utilization in %. |
Calculated | vm.memory.util[memoryUsedPercentage.0] |
| Netgear Fastpath: Operating system | MIB: FASTPATH-SWITCHING-MIB Operating System running on this unit |
SNMP agent | system.sw.os[agentInventoryOperatingSystem.0] Preprocessing
|
| Netgear Fastpath: Hardware model name | MIB: FASTPATH-SWITCHING-MIB |
SNMP agent | system.hw.model Preprocessing
|
| Netgear Fastpath: Hardware serial number | MIB: FASTPATH-SWITCHING-MIB Serial number of the switch |
SNMP agent | system.hw.serialnumber Preprocessing
|
| Netgear Fastpath: Uptime (network) | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
| Netgear Fastpath: Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
| Netgear Fastpath: SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
| Netgear Fastpath: System location | MIB: SNMPv2-MIB The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
| Netgear Fastpath: System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
| Netgear Fastpath: System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
| Netgear Fastpath: System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
| Netgear Fastpath: System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
| Netgear Fastpath: SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible value: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
| Netgear Fastpath: ICMP ping | Simple check | icmpping | |
| Netgear Fastpath: ICMP loss | Simple check | icmppingloss | |
| Netgear Fastpath: ICMP response time | Simple check | icmppingsec |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Netgear Fastpath by SNMP/system.cpu.util[agentSwitchCpuProcessTotalUtilization.0],5m)>{$CPU.UTIL.CRIT} |
Warning | |
| Netgear Fastpath: High memory utilization | The system is running out of free memory. |
min(/Netgear Fastpath by SNMP/vm.memory.util[memoryUsedPercentage.0],5m)>{$MEMORY.UTIL.MAX} |
Average | |
| Netgear Fastpath: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#1)<>last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#2) and length(last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0]))>0 |
Info | Manual close: Yes Depends on:
|
| Netgear Fastpath: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#1)<>last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#2) and length(last(/Netgear Fastpath by SNMP/system.hw.serialnumber))>0 |
Info | Manual close: Yes |
| Netgear Fastpath: Host has been restarted | Uptime is less than 10 minutes. |
(last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Netgear Fastpath by SNMP/system.net.uptime[sysUpTime.0])<10m) |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.name,#1)<>last(/Netgear Fastpath by SNMP/system.name,#2) and length(last(/Netgear Fastpath by SNMP/system.name))>0 |
Info | Manual close: Yes |
| Netgear Fastpath: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Netgear Fastpath by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
| Netgear Fastpath: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Netgear Fastpath by SNMP/icmpping,#3)=0 |
High | |
| Netgear Fastpath: High ICMP ping loss | min(/Netgear Fastpath by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Netgear Fastpath by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
|
| Netgear Fastpath: High ICMP ping response time | avg(/Netgear Fastpath by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable |
SNMP agent | temp.discovery |
Item prototypes for Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Temperature | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The temperature value reported by sensor |
SNMP agent | sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}] |
| #{#SNMPVALUE}: Temperature status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The state of temperature sensor |
SNMP agent | sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}] |
Trigger prototypes for Temperature Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| #{#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_WARN_STATUS} |
Warning | Depends on:
|
| #{#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS} |
High | |
| #{#SNMPVALUE}: Temperature is too low | avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average |
LLD rule FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::1.3.6.1.4.1.4526.10.43.1.6.1.1 |
SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Fan status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of fan |
SNMP agent | sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| #{#SNMPVALUE}: Fan is in critical state | Please check the fan unit |
count(/Netgear Fastpath by SNMP/sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"failed\"}")=1 |
Average |
LLD rule PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| PSU Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesPowSupplyIndex |
SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Power supply status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of power supply |
SNMP agent | sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| #{#SNMPVALUE}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Netgear Fastpath by SNMP/sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"failed\"}")=1 |
Average |
LLD rule Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
| Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Netgear Fastpath by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Netgear Fastpath by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
| Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Netgear Fastpath by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Netgear Fastpath by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
| Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums
Netgear Fastpath by SNMP
Overview
For Zabbix version: 6.2 and higher. https://kb.netgear.com/24352/MIBs-for-Smart-switches
This template was tested on:
- Netgear M5300-28G
Setup
Refer to the vendor documentation.
Zabbix configuration
No specific Zabbix configuration is required.
Macros used
| Name | Description | Default |
|---|---|---|
| {$CPU.UTIL.CRIT} | - |
90 |
| {$FAN_CRIT_STATUS:"failed"} | - |
2 |
| {$ICMP_LOSS_WARN} | - |
20 |
| {$ICMP_RESPONSE_TIME_WARN} | - |
0.15 |
| {$IF.ERRORS.WARN} | - |
2 |
| {$IF.UTIL.MAX} | - |
90 |
| {$IFCONTROL} | - |
1 |
| {$MEMORY.UTIL.MAX} | - |
90 |
| {$NET.IF.IFADMINSTATUS.MATCHES} | Ignore notPresent(6) |
^.* |
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFALIAS.MATCHES} | - |
.* |
| {$NET.IF.IFALIAS.NOT_MATCHES} | - |
CHANGE_IF_NEEDED |
| {$NET.IF.IFDESCR.MATCHES} | - |
.* |
| {$NET.IF.IFDESCR.NOT_MATCHES} | - |
CHANGE_IF_NEEDED |
| {$NET.IF.IFNAME.MATCHES} | - |
^.*$ |
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
`(^Software Loopback Interface |
| {$NET.IF.IFOPERSTATUS.MATCHES} | - |
^.*$ |
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFTYPE.MATCHES} | - |
.* |
| {$NET.IF.IFTYPE.NOT_MATCHES} | - |
CHANGE_IF_NEEDED |
| {$PSU_CRIT_STATUS:"failed"} | - |
2 |
| {$SNMP.TIMEOUT} | - |
5m |
| {$TEMP_CRIT_LOW} | - |
5 |
| {$TEMP_CRIT_STATUS} | - |
3 |
| {$TEMP_CRIT} | - |
60 |
| {$TEMP_WARN_STATUS} | - |
2 |
| {$TEMP_WARN} | - |
50 |
Template links
There are no template links in this template.
Discovery rules
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::1.3.6.1.4.1.4526.10.43.1.6.1.1 |
SNMP | fan.discovery |
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP | net.if.discovery Filter: AND- {#IFADMINSTATUS} MATCHES_REGEX - {#IFADMINSTATUS} NOT_MATCHES_REGEX - {#IFOPERSTATUS} MATCHES_REGEX - {#IFOPERSTATUS} NOT_MATCHES_REGEX - {#IFNAME} MATCHES_REGEX - {#IFNAME} NOT_MATCHES_REGEX - {#IFDESCR} MATCHES_REGEX - {#IFDESCR} NOT_MATCHES_REGEX - {#IFALIAS} MATCHES_REGEX - {#IFALIAS} NOT_MATCHES_REGEX - {#IFTYPE} MATCHES_REGEX - {#IFTYPE} NOT_MATCHES_REGEX |
| PSU Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesPowSupplyIndex |
SNMP | psu.discovery |
| Temperature Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable |
SNMP | temp.discovery |
Items collected
| Group | Name | Description | Type | Key and additional info |
|---|---|---|---|---|
| CPU | CPU utilization | MIB: FASTPATH-SWITCHING-MIB CPU utilization in %. |
SNMP | system.cpu.util[agentSwitchCpuProcessTotalUtilization.0] Preprocessing: - REGEX: |
| Fans | #{#SNMPVALUE}: Fan status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of fan |
SNMP | sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}] |
| General | SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP_TRAP | snmptrap.fallback |
| General | System location | MIB: SNMPv2-MIB The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. |
SNMP | system.location[sysLocation.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| General | System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP | system.contact[sysContact.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| General | System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP | system.objectid[sysObjectID.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| General | System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP | system.name Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| General | System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP | system.descr[sysDescr.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Inventory | Operating system | MIB: FASTPATH-SWITCHING-MIB Operating System running on this unit |
SNMP | system.sw.os[agentInventoryOperatingSystem.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Inventory | Hardware model name | MIB: FASTPATH-SWITCHING-MIB |
SNMP | system.hw.model Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Inventory | Hardware serial number | MIB: FASTPATH-SWITCHING-MIB Serial number of the switch |
SNMP | system.hw.serialnumber Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Memory | Available memory | MIB: FASTPATH-SWITCHING-MIB The total memory freed for utilization. |
SNMP | vm.memory.available[agentSwitchCpuProcessMemFree.0] |
| Memory | Total memory | MIB: FASTPATH-SWITCHING-MIB The total Memory allocated for the tasks |
SNMP | vm.memory.total[agentSwitchCpuProcessMemAvailable.0] |
| Memory | Memory utilization | Memory utilization in %. |
CALCULATED | vm.memory.util[memoryUsedPercentage.0] Expression: (last(//vm.memory.total[agentSwitchCpuProcessMemAvailable.0])-last(//vm.memory.available[agentSwitchCpuProcessMemFree.0]))/last(//vm.memory.total[agentSwitchCpuProcessMemAvailable.0])*100 |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND - MULTIPLIER: |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND - MULTIPLIER: |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP | net.if.type[ifType.{#SNMPINDEX}] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing: - MULTIPLIER: - DISCARD_UNCHANGED_HEARTBEAT: |
| Power supply | #{#SNMPVALUE}: Power supply status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of power supply |
SNMP | sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}] |
| Status | Uptime (network) | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP | system.net.uptime[sysUpTime.0] Preprocessing: - MULTIPLIER: |
| Status | Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP | system.hw.uptime[hrSystemUptime.0] Preprocessing: - CHECK_NOT_SUPPORTED ⛔️ON_FAIL: - MULTIPLIER: |
| Status | SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible value: 0 - not available 1 - available 2 - unknown |
INTERNAL | zabbix[host,snmp,available] |
| Status | ICMP ping | - |
SIMPLE | icmpping |
| Status | ICMP loss | - |
SIMPLE | icmppingloss |
| Status | ICMP response time | - |
SIMPLE | icmppingsec |
| Temperature | #{#SNMPVALUE}: Temperature | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The temperature value reported by sensor |
SNMP | sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}] |
| Temperature | #{#SNMPVALUE}: Temperature status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The state of temperature sensor |
SNMP | sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}] |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| High CPU utilization | CPU utilization is too high. The system might be slow to respond. |
min(/Netgear Fastpath by SNMP/system.cpu.util[agentSwitchCpuProcessTotalUtilization.0],5m)>{$CPU.UTIL.CRIT} |
WARNING | |
| #{#SNMPVALUE}: Fan is in critical state | Please check the fan unit |
count(/Netgear Fastpath by SNMP/sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"failed\"}")=1 |
AVERAGE | |
| System name has changed | System name has changed. Ack to close. |
last(/Netgear Fastpath by SNMP/system.name,#1)<>last(/Netgear Fastpath by SNMP/system.name,#2) and length(last(/Netgear Fastpath by SNMP/system.name))>0 |
INFO | Manual close: YES |
| Operating system description has changed | Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close. |
last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#1)<>last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#2) and length(last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0]))>0 |
INFO | Manual close: YES Depends on: - System name has changed |
| Device has been replaced | Device serial number has changed. Ack to close |
last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#1)<>last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#2) and length(last(/Netgear Fastpath by SNMP/system.hw.serialnumber))>0 |
INFO | Manual close: YES |
| High memory utilization | The system is running out of free memory. |
min(/Netgear Fastpath by SNMP/vm.memory.util[memoryUsedPercentage.0],5m)>{$MEMORY.UTIL.MAX} |
AVERAGE | |
| Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: 1. Can be triggered if operations status is down. 2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down. 3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.) WARNING: if closed manually - won't fire again on next poll, because of .diff. |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))Recovery expression: last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0 |
AVERAGE | Manual close: YES |
| Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The network interface utilization is close to its estimated maximum bandwidth. |
(avg(/Netgear Fastpath by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Netgear Fastpath by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0Recovery expression: avg(/Netgear Fastpath by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and avg(/Netgear Fastpath by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) |
WARNING | Manual close: YES Depends on: - Interface {#IFNAME}({#IFALIAS}): Link down |
| Interface {#IFNAME}({#IFALIAS}): High error rate | Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold |
min(/Netgear Fastpath by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Netgear Fastpath by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}Recovery expression: max(/Netgear Fastpath by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 and max(/Netgear Fastpath by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 |
WARNING | Manual close: YES Depends on: - Interface {#IFNAME}({#IFALIAS}): Link down |
| Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close. |
change(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)Recovery expression: (change(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2) |
INFO | Manual close: YES Depends on: - Interface {#IFNAME}({#IFALIAS}): Link down |
| #{#SNMPVALUE}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Netgear Fastpath by SNMP/sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"failed\"}")=1 |
AVERAGE | |
| Host has been restarted | Uptime is less than 10 minutes. |
(last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Netgear Fastpath by SNMP/system.net.uptime[sysUpTime.0])<10m) |
WARNING | Manual close: YES Depends on: - No SNMP data collection |
| No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Netgear Fastpath by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
WARNING | Depends on: - Unavailable by ICMP ping |
| Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Netgear Fastpath by SNMP/icmpping,#3)=0 |
HIGH | |
| High ICMP ping loss | - |
min(/Netgear Fastpath by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Netgear Fastpath by SNMP/icmppingloss,5m)<100 |
WARNING | Depends on: - Unavailable by ICMP ping |
| High ICMP ping response time | - |
avg(/Netgear Fastpath by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
WARNING | Depends on: - High ICMP ping loss - Unavailable by ICMP ping |
| #{#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_WARN_STATUS} Recovery expression: max(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3 |
WARNING | Depends on: - #{#SNMPVALUE}: Temperature is above critical threshold |
| #{#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS} Recovery expression: max(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3 |
HIGH | |
| #{#SNMPVALUE}: Temperature is too low | - |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}Recovery expression: min(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3 |
AVERAGE |
Feedback
Please report any issues with the template at https://support.zabbix.com.
Netgear Fastpath by SNMP
Overview
https://kb.netgear.com/24352/MIBs-for-Smart-switches
Requirements
Zabbix version: 6.0 and higher.
Tested versions
This template has been tested on:
- Netgear M5300-28G
Configuration
Zabbix should be configured according to the instructions in the Templates out of the box section.
Setup
Refer to the vendor documentation.
Macros used
| Name | Description | Default |
|---|---|---|
| {$CPU.UTIL.CRIT} | 90 |
|
| {$TEMP_CRIT} | 60 |
|
| {$TEMP_CRIT_LOW} | 5 |
|
| {$TEMP_WARN} | 50 |
|
| {$TEMP_WARN_STATUS} | 2 |
|
| {$TEMP_CRIT_STATUS} | 3 |
|
| {$PSU_CRIT_STATUS:"failed"} | 2 |
|
| {$FAN_CRIT_STATUS:"failed"} | 2 |
|
| {$MEMORY.UTIL.MAX} | 90 |
|
| {$SNMP.TIMEOUT} | 5m |
|
| {$ICMP_LOSS_WARN} | 20 |
|
| {$ICMP_RESPONSE_TIME_WARN} | 0.15 |
|
| {$IF.ERRORS.WARN} | 2 |
|
| {$IF.UTIL.MAX} | 90 |
|
| {$IFCONTROL} | 1 |
|
| {$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
| {$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFADMINSTATUS.MATCHES} | ^.* |
|
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFDESCR.MATCHES} | .* |
|
| {$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFALIAS.MATCHES} | .* |
|
| {$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFTYPE.MATCHES} | .* |
|
| {$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Netgear Fastpath: CPU utilization | MIB: FASTPATH-SWITCHING-MIB The CPU utilization expressed in %. |
SNMP agent | system.cpu.util[agentSwitchCpuProcessTotalUtilization.0] Preprocessing
|
| Netgear Fastpath: Available memory | MIB: FASTPATH-SWITCHING-MIB The total memory freed for utilization. |
SNMP agent | vm.memory.available[agentSwitchCpuProcessMemFree.0] |
| Netgear Fastpath: Total memory | MIB: FASTPATH-SWITCHING-MIB The total Memory allocated for the tasks |
SNMP agent | vm.memory.total[agentSwitchCpuProcessMemAvailable.0] |
| Netgear Fastpath: Memory utilization | Memory utilization in %. |
Calculated | vm.memory.util[memoryUsedPercentage.0] |
| Netgear Fastpath: Operating system | MIB: FASTPATH-SWITCHING-MIB Operating System running on this unit |
SNMP agent | system.sw.os[agentInventoryOperatingSystem.0] Preprocessing
|
| Netgear Fastpath: Hardware model name | MIB: FASTPATH-SWITCHING-MIB |
SNMP agent | system.hw.model Preprocessing
|
| Netgear Fastpath: Hardware serial number | MIB: FASTPATH-SWITCHING-MIB Serial number of the switch |
SNMP agent | system.hw.serialnumber Preprocessing
|
| Netgear Fastpath: Uptime (network) | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
| Netgear Fastpath: Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
| Netgear Fastpath: SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
| Netgear Fastpath: System location | MIB: SNMPv2-MIB The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
| Netgear Fastpath: System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
| Netgear Fastpath: System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
| Netgear Fastpath: System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
| Netgear Fastpath: System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
| Netgear Fastpath: SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible value: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
| Netgear Fastpath: ICMP ping | Simple check | icmpping | |
| Netgear Fastpath: ICMP loss | Simple check | icmppingloss | |
| Netgear Fastpath: ICMP response time | Simple check | icmppingsec |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Netgear Fastpath: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Netgear Fastpath by SNMP/system.cpu.util[agentSwitchCpuProcessTotalUtilization.0],5m)>{$CPU.UTIL.CRIT} |
Warning | |
| Netgear Fastpath: High memory utilization | The system is running out of free memory. |
min(/Netgear Fastpath by SNMP/vm.memory.util[memoryUsedPercentage.0],5m)>{$MEMORY.UTIL.MAX} |
Average | |
| Netgear Fastpath: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#1)<>last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0],#2) and length(last(/Netgear Fastpath by SNMP/system.sw.os[agentInventoryOperatingSystem.0]))>0 |
Info | Manual close: Yes Depends on:
|
| Netgear Fastpath: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#1)<>last(/Netgear Fastpath by SNMP/system.hw.serialnumber,#2) and length(last(/Netgear Fastpath by SNMP/system.hw.serialnumber))>0 |
Info | Manual close: Yes |
| Netgear Fastpath: Host has been restarted | Uptime is less than 10 minutes. |
(last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Netgear Fastpath by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Netgear Fastpath by SNMP/system.net.uptime[sysUpTime.0])<10m) |
Warning | Manual close: Yes Depends on:
|
| Netgear Fastpath: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Netgear Fastpath by SNMP/system.name,#1)<>last(/Netgear Fastpath by SNMP/system.name,#2) and length(last(/Netgear Fastpath by SNMP/system.name))>0 |
Info | Manual close: Yes |
| Netgear Fastpath: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Netgear Fastpath by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
| Netgear Fastpath: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Netgear Fastpath by SNMP/icmpping,#3)=0 |
High | |
| Netgear Fastpath: High ICMP ping loss | min(/Netgear Fastpath by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Netgear Fastpath by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
|
| Netgear Fastpath: High ICMP ping response time | avg(/Netgear Fastpath by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable |
SNMP agent | temp.discovery |
Item prototypes for Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Temperature | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The temperature value reported by sensor |
SNMP agent | sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}] |
| #{#SNMPVALUE}: Temperature status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The state of temperature sensor |
SNMP agent | sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}] |
Trigger prototypes for Temperature Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| #{#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_WARN_STATUS} |
Warning | Depends on:
|
| #{#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} or last(/Netgear Fastpath by SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS} |
High | |
| #{#SNMPVALUE}: Temperature is too low | avg(/Netgear Fastpath by SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average |
LLD rule FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::1.3.6.1.4.1.4526.10.43.1.6.1.1 |
SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Fan status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of fan |
SNMP agent | sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| #{#SNMPVALUE}: Fan is in critical state | Please check the fan unit |
count(/Netgear Fastpath by SNMP/sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"failed\"}")=1 |
Average |
LLD rule PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| PSU Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesPowSupplyIndex |
SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPVALUE}: Power supply status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of power supply |
SNMP agent | sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| #{#SNMPVALUE}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Netgear Fastpath by SNMP/sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"failed\"}")=1 |
Average |
LLD rule Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
| Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Netgear Fastpath by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Netgear Fastpath by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
| Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Netgear Fastpath by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Netgear Fastpath by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
| Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Netgear Fastpath by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Netgear Fastpath by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Netgear Fastpath by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums
Netgear Fastpath SNMP
Overview
For Zabbix version: 5.4 and higher
https://kb.netgear.com/24352/MIBs-for-Smart-switches
This template was tested on:
- Netgear M5300-28G
Setup
Refer to the vendor documentation.
Zabbix configuration
No specific Zabbix configuration is required.
Macros used
| Name | Description | Default |
|---|---|---|
| {$CPU.UTIL.CRIT} | - |
90 |
| {$FAN_CRIT_STATUS:"failed"} | - |
2 |
| {$MEMORY.UTIL.MAX} | - |
90 |
| {$PSU_CRIT_STATUS:"failed"} | - |
2 |
| {$TEMP_CRIT_LOW} | - |
5 |
| {$TEMP_CRIT_STATUS} | - |
3 |
| {$TEMP_CRIT} | - |
60 |
| {$TEMP_WARN_STATUS} | - |
2 |
| {$TEMP_WARN} | - |
50 |
Template links
| Name |
|---|
| Generic SNMP |
| Interfaces SNMP |
Discovery rules
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable |
SNMP | temp.discovery |
| FAN Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::1.3.6.1.4.1.4526.10.43.1.6.1.1 |
SNMP | fan.discovery |
| PSU Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesPowSupplyIndex |
SNMP | psu.discovery |
Items collected
| Group | Name | Description | Type | Key and additional info |
|---|---|---|---|---|
| CPU | CPU utilization | MIB: FASTPATH-SWITCHING-MIB CPU utilization in % |
SNMP | system.cpu.util[agentSwitchCpuProcessTotalUtilization.0] Preprocessing: - REGEX: |
| Fans | #{#SNMPVALUE}: Fan status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of fan |
SNMP | sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}] |
| Inventory | Operating system | MIB: FASTPATH-SWITCHING-MIB Operating System running on this unit |
SNMP | system.sw.os[agentInventoryOperatingSystem.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Inventory | Hardware model name | MIB: FASTPATH-SWITCHING-MIB |
SNMP | system.hw.model Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Inventory | Hardware serial number | MIB: FASTPATH-SWITCHING-MIB Serial number of the switch |
SNMP | system.hw.serialnumber Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Memory | Available memory | MIB: FASTPATH-SWITCHING-MIB The total memory freed for utilization. |
SNMP | vm.memory.available[agentSwitchCpuProcessMemFree.0] |
| Memory | Total memory | MIB: FASTPATH-SWITCHING-MIB The total Memory allocated for the tasks |
SNMP | vm.memory.total[agentSwitchCpuProcessMemAvailable.0] |
| Memory | Memory utilization | Memory utilization in % |
CALCULATED | vm.memory.util[memoryUsedPercentage.0] Expression: (last(//vm.memory.total[agentSwitchCpuProcessMemAvailable.0])-last(//vm.memory.available[agentSwitchCpuProcessMemFree.0]))/last(//vm.memory.total[agentSwitchCpuProcessMemAvailable.0])*100 |
| Power_supply | #{#SNMPVALUE}: Power supply status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of power supply |
SNMP | sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}] |
| Temperature | #{#SNMPVALUE}: Temperature | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The temperature value reported by sensor |
SNMP | sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}] |
| Temperature | #{#SNMPVALUE}: Temperature status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The state of temperature sensor |
SNMP | sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}] |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m) | CPU utilization is too high. The system might be slow to respond. |
min(/Netgear Fastpath SNMP/system.cpu.util[agentSwitchCpuProcessTotalUtilization.0],5m)>{$CPU.UTIL.CRIT} |
WARNING | |
| #{#SNMPVALUE}: Fan is in critical state | Please check the fan unit |
count(/Netgear Fastpath SNMP/sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"failed\"}")=1 |
AVERAGE | |
| Operating system description has changed | Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close. |
last(/Netgear Fastpath SNMP/system.sw.os[agentInventoryOperatingSystem.0],#1)<>last(/Netgear Fastpath SNMP/system.sw.os[agentInventoryOperatingSystem.0],#2) and length(last(/Netgear Fastpath SNMP/system.sw.os[agentInventoryOperatingSystem.0]))>0 |
INFO | Manual close: YES |
| Device has been replaced (new serial number received) | Device serial number has changed. Ack to close |
last(/Netgear Fastpath SNMP/system.hw.serialnumber,#1)<>last(/Netgear Fastpath SNMP/system.hw.serialnumber,#2) and length(last(/Netgear Fastpath SNMP/system.hw.serialnumber))>0 |
INFO | Manual close: YES |
| High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m) | The system is running out of free memory. |
min(/Netgear Fastpath SNMP/vm.memory.util[memoryUsedPercentage.0],5m)>{$MEMORY.UTIL.MAX} |
AVERAGE | |
| #{#SNMPVALUE}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Netgear Fastpath SNMP/sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"failed\"}")=1 |
AVERAGE | |
| #{#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:""} | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:""} or last(/Netgear Fastpath SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_WARN_STATUS} Recovery expression: max(/Netgear Fastpath SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3 |
WARNING | Depends on: - #{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:""} |
| #{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:""} | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Netgear Fastpath SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""} or last(/Netgear Fastpath SNMP/sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS} Recovery expression: max(/Netgear Fastpath SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3 |
HIGH | |
| #{#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:""} | - |
avg(/Netgear Fastpath SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}Recovery expression: min(/Netgear Fastpath SNMP/sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3 |
AVERAGE |
Feedback
Please report any issues with the template at https://support.zabbix.com
Template Net Netgear Fastpath SNMP
Overview
For Zabbix version: 5.0 and higher
https://kb.netgear.com/24352/MIBs-for-Smart-switches
This template was tested on:
- Netgear M5300-28G
Setup
Refer to the vendor documentation.
Zabbix configuration
No specific Zabbix configuration is required.
Macros used
| Name | Description | Default |
|---|---|---|
| {$CPU.UTIL.CRIT} | - |
90 |
| {$FAN_CRIT_STATUS:"failed"} | - |
2 |
| {$MEMORY.UTIL.MAX} | - |
90 |
| {$PSU_CRIT_STATUS:"failed"} | - |
2 |
| {$TEMP_CRIT_LOW} | - |
5 |
| {$TEMP_CRIT_STATUS} | - |
3 |
| {$TEMP_CRIT} | - |
60 |
| {$TEMP_WARN_STATUS} | - |
2 |
| {$TEMP_WARN} | - |
50 |
Template links
| Name |
|---|
| Generic SNMP |
| Interfaces SNMP |
Discovery rules
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable |
SNMP | temp.discovery |
| FAN Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::1.3.6.1.4.1.4526.10.43.1.6.1.1 |
SNMP | fan.discovery |
| PSU Discovery | FASTPATH-BOXSERVICES-PRIVATE-MIB::boxServicesPowSupplyIndex |
SNMP | psu.discovery |
Items collected
| Group | Name | Description | Type | Key and additional info |
|---|---|---|---|---|
| CPU | CPU utilization | MIB: FASTPATH-SWITCHING-MIB CPU utilization in % |
SNMP | system.cpu.util[agentSwitchCpuProcessTotalUtilization.0] Preprocessing: - REGEX: |
| Fans | #{#SNMPVALUE}: Fan status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of fan |
SNMP | sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}] |
| Inventory | Operating system | MIB: FASTPATH-SWITCHING-MIB Operating System running on this unit |
SNMP | system.sw.os[agentInventoryOperatingSystem.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Inventory | Hardware model name | MIB: FASTPATH-SWITCHING-MIB |
SNMP | system.hw.model Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Inventory | Hardware serial number | MIB: FASTPATH-SWITCHING-MIB Serial number of the switch |
SNMP | system.hw.serialnumber Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Memory | Available memory | MIB: FASTPATH-SWITCHING-MIB The total memory freed for utilization. |
SNMP | vm.memory.available[agentSwitchCpuProcessMemFree.0] |
| Memory | Total memory | MIB: FASTPATH-SWITCHING-MIB The total Memory allocated for the tasks |
SNMP | vm.memory.total[agentSwitchCpuProcessMemAvailable.0] |
| Memory | Memory utilization | Memory utilization in % |
CALCULATED | vm.memory.util[memoryUsedPercentage.0] Expression: (last("vm.memory.total[agentSwitchCpuProcessMemAvailable.0]")-last("vm.memory.available[agentSwitchCpuProcessMemFree.0]"))/last("vm.memory.total[agentSwitchCpuProcessMemAvailable.0]")*100 |
| Power_supply | #{#SNMPVALUE}: Power supply status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The status of power supply |
SNMP | sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}] |
| Temperature | #{#SNMPVALUE}: Temperature | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The temperature value reported by sensor |
SNMP | sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}] |
| Temperature | #{#SNMPVALUE}: Temperature status | MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB The state of temperature sensor |
SNMP | sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}] |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m) | CPU utilization is too high. The system might be slow to respond. |
{TEMPLATE_NAME:system.cpu.util[agentSwitchCpuProcessTotalUtilization.0].min(5m)}>{$CPU.UTIL.CRIT} |
WARNING | |
| #{#SNMPVALUE}: Fan is in critical state | Please check the fan unit |
{TEMPLATE_NAME:sensor.fan.status[boxServicesFanItemState.{#SNMPINDEX}].count(#1,{$FAN_CRIT_STATUS:"failed"},eq)}=1 |
AVERAGE | |
| Operating system description has changed | Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close. |
{TEMPLATE_NAME:system.sw.os[agentInventoryOperatingSystem.0].diff()}=1 and {TEMPLATE_NAME:system.sw.os[agentInventoryOperatingSystem.0].strlen()}>0 |
INFO | Manual close: YES |
| Device has been replaced (new serial number received) | Device serial number has changed. Ack to close |
{TEMPLATE_NAME:system.hw.serialnumber.diff()}=1 and {TEMPLATE_NAME:system.hw.serialnumber.strlen()}>0 |
INFO | Manual close: YES |
| High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m) | The system is running out of free memory. |
{TEMPLATE_NAME:vm.memory.util[memoryUsedPercentage.0].min(5m)}>{$MEMORY.UTIL.MAX} |
AVERAGE | |
| #{#SNMPVALUE}: Power supply is in critical state | Please check the power supply unit for errors |
{TEMPLATE_NAME:sensor.psu.status[boxServicesPowSupplyItemState.{#SNMPINDEX}].count(#1,{$PSU_CRIT_STATUS:"failed"},eq)}=1 |
AVERAGE | |
| #{#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:""} | This trigger uses temperature sensor values as well as temperature sensor status if available |
{TEMPLATE_NAME:sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}].avg(5m)}>{$TEMP_WARN:""} or {TEMPLATE_NAME:sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}].last()}={$TEMP_WARN_STATUS}Recovery expression: {TEMPLATE_NAME:sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}].max(5m)}<{$TEMP_WARN:""}-3 |
WARNING | Depends on: - #{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:""} |
| #{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:""} | This trigger uses temperature sensor values as well as temperature sensor status if available |
{TEMPLATE_NAME:sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:""} or {TEMPLATE_NAME:sensor.temp.status[boxServicesTempSensorState.{#SNMPINDEX}].last()}={$TEMP_CRIT_STATUS}Recovery expression: {TEMPLATE_NAME:sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}].max(5m)}<{$TEMP_CRIT:""}-3 |
HIGH | |
| #{#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:""} | - |
{TEMPLATE_NAME:sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}].avg(5m)}<{$TEMP_CRIT_LOW:""}Recovery expression: {TEMPLATE_NAME:sensor.temp.value[boxServicesTempSensorTemperature.{#SNMPINDEX}].min(5m)}>{$TEMP_CRIT_LOW:""}+3 |
AVERAGE |
Feedback
Please report any issues with the template at https://support.zabbix.com