| Name | Description | Default |
|---|---|---|
| {$TEMP_CRIT_LOW} | 5 |
|
| {$TEMP_CRIT} | 75 |
|
| {$TEMP_WARN} | 65 |
|
| {$PSU_CRIT_STATUS} | 4 |
|
| {$FAN_CRIT_STATUS} | 4 |
|
| {$MEMORY.UTIL.MAX} | 90 |
|
| {$CPU.UTIL.CRIT} | 90 |
|
| {$SNMP.TIMEOUT} | Time interval for the SNMP availability trigger. |
5m |
| {$SNMP.UPTIME.WARN} | Uptime threshold above which the "Host has been restarted" problem auto-resolves. |
10m |
| {$ICMP_LOSS_WARN} | Warning threshold of ICMP packet loss in %. |
20 |
| {$ICMP_RESPONSE_TIME_WARN} | Warning threshold of the average ICMP response time in seconds. |
0.15 |
| {$IF.ERRORS.WARN} | Warning threshold of error packet rate. Can be used with interface name as context. |
2 |
| {$IF.UTIL.MAX} | 90 |
|
| {$IFCONTROL} | 1 |
|
| {$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
| {$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFADMINSTATUS.MATCHES} | ^.* |
|
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFDESCR.MATCHES} | .* |
|
| {$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFALIAS.MATCHES} | .* |
|
| {$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFTYPE.MATCHES} | .* |
|
| {$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| CPU utilization | MIB: TIMETRA-SYSTEM-MIB The value of sgiCpuUsage indicates the current CPU utilization for the system. |
SNMP agent | system.cpu.util[sgiCpuUsage.0] |
| Used memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryUsed indicates the total pre-allocated pool memory, in kilobytes, currently in use on the system. |
SNMP agent | vm.memory.used[sgiKbMemoryUsed.0] Preprocessing
|
| Available memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryAvailable indicates the amount of free memory, in kilobytes, in the overall system that is not allocated to memory pools, but is available in case a memory pool needs to grow. |
SNMP agent | vm.memory.available[sgiKbMemoryAvailable.0] Preprocessing
|
| Total memory | The total memory expressed in bytes. |
Calculated | vm.memory.total[snmp] |
| Memory utilization | Memory utilization in %. |
Calculated | vm.memory.util[vm.memory.util.0] |
| Hardware model name | MIB: SNMPv2-MIB |
SNMP agent | system.hw.model Preprocessing
|
| Operating system | MIB: SNMPv2-MIB |
SNMP agent | system.sw.os[sysDescr.0] Preprocessing
|
| Uptime (network) | MIB: SNMPv2-MIB Time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
| Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
| SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
| System location | MIB: SNMPv2-MIB Physical location of the node (e.g., |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
| System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
| System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
| System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
| System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
| SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible values: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
| ICMP ping | The host accessibility by ICMP ping. 0 - ICMP ping fails; 1 - ICMP ping successful. |
Simple check | icmpping |
| ICMP loss | The percentage of lost packets. |
Simple check | icmppingloss |
| ICMP response time | The ICMP ping response time (in seconds). |
Simple check | icmppingsec |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Alcatel Timetra TiMOS by SNMP/system.cpu.util[sgiCpuUsage.0],5m)>{$CPU.UTIL.CRIT} |
Warning | |
| Alcatel TiMOS: High memory utilization | The system is running out of free memory. |
min(/Alcatel Timetra TiMOS by SNMP/vm.memory.util[vm.memory.util.0],5m)>{$MEMORY.UTIL.MAX} |
Average | |
| Alcatel TiMOS: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0]))>0 |
Info | Manual close: Yes Depends on:
|
| Alcatel TiMOS: Host has been restarted | The uptime counter has decreased, which indicates that the host has been restarted. |
(last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and change(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])<0 and last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0],#2)<42949672.96-(lastclock(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])-lastclock(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0],#2))) or (last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and change(/Alcatel Timetra TiMOS by SNMP/system.net.uptime[sysUpTime.0])<0 and last(/Alcatel Timetra TiMOS by SNMP/system.net.uptime[sysUpTime.0],#2)<42949672.96-(lastclock(/Alcatel Timetra TiMOS by SNMP/system.net.uptime[sysUpTime.0])-lastclock(/Alcatel Timetra TiMOS by SNMP/system.net.uptime[sysUpTime.0],#2))) |
Warning | Manual close: Yes Depends on:
|
| Alcatel TiMOS: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.name,#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.name,#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.name))>0 |
Info | Manual close: Yes |
| Alcatel TiMOS: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Alcatel Timetra TiMOS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
| Alcatel TiMOS: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Alcatel Timetra TiMOS by SNMP/icmpping,#3)=0 |
High | |
| Alcatel TiMOS: High ICMP ping loss | ICMP packets loss detected. |
min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
| Alcatel TiMOS: High ICMP ping response time | Average ICMP response time is too high. |
avg(/Alcatel Timetra TiMOS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | SNMP agent | temperature.discovery |
Item prototypes for Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| {#SNMPVALUE}: Temperature | MIB: TIMETRA-SYSTEM-MIB The current temperature reading in degrees celsius from this hardware component's temperature sensor. If this component does not contain a temperature sensor, then the value -1 is returned. |
SNMP agent | sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}] |
Trigger prototypes for Temperature Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: {#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} |
Warning | Depends on:
|
| Alcatel TiMOS: {#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} |
High | |
| Alcatel TiMOS: {#SNMPVALUE}: Temperature is too low | avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average |
LLD rule FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPINDEX}: Fan status | MIB: TIMETRA-SYSTEM-MIB Current status of the Fan tray. |
SNMP agent | sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: #{#SNMPINDEX}: Fan is in critical state | Please check the fan unit |
count(/Alcatel Timetra TiMOS by SNMP/sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1 |
Average |
LLD rule PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| PSU Discovery | SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the first power supply in the tray (or shelf). For any other type, this represents the overall status of the power supply. If tmnxChassisPowerSupply1Status is'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP agent | sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}] |
| #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the second power supply in the tray (or shelf). For any other type, this field is unused and set to 'deviceNotEquipped'. If tmnxChassisPowerSupply2Status is 'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP agent | sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average | |
| Alcatel TiMOS: #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average |
LLD rule Entity Serial Numbers Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Entity Serial Numbers Discovery | SNMP agent | entity_sn.discovery |
Item prototypes for Entity Serial Numbers Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| {#ENT_NAME}: Hardware serial number | MIB: TIMETRA-CHASSIS-MIB |
SNMP agent | system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Entity Serial Numbers Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: {#ENT_NAME}: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}]))>0 |
Info | Manual close: Yes |
LLD rule Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Alcatel Timetra TiMOS by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Alcatel Timetra TiMOS by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Alcatel Timetra TiMOS by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Alcatel Timetra TiMOS by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
LLD rule EtherLike-MIB Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| EtherLike-MIB Discovery | Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered. |
SNMP agent | net.if.duplex.discovery Preprocessing
|
Item prototypes for EtherLike-MIB Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Duplex status | MIB: EtherLike-MIB The current mode of operation of the MAC entity. 'unknown' indicates that the current duplex mode could not be determined. Management control of the duplex mode is accomplished through the MAU MIB. When an interface does not support autonegotiation, or when autonegotiation is not enabled, the duplex mode is controlled using ifMauDefaultType. When autonegotiation is supported and enabled, duplex mode is controlled using ifMauAutoNegAdvertisedBits. In either case, the currently operating duplex mode is reflected both in this object and in ifMauType. Note that this object provides redundant information with ifMauType. Normally, redundant objects are discouraged. However, in this instance, it allows a management application to determine the duplex status of an interface without having to know every possible value of ifMauType. This was felt to be sufficiently valuable to justify the redundancy. Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus. |
SNMP agent | net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}] |
Trigger prototypes for EtherLike-MIB Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): In half-duplex mode | Please check autonegotiation settings and cabling. |
last(/Alcatel Timetra TiMOS by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2 |
Warning | Manual close: Yes |
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums
Vendor and Community integrations are created by third parties and are not verified by Zabbix. Zabbix is not responsible for their functionality or quality.
Zabbix community templates
2 Contributed to the zabbix/community-templates repositoryAlcatel-Lucent Enterprise OmniSwitch AOS Release 8.xThis template allows to monitor Alcatel-Lucent Enterprise OmniSwitch running AOS Release 8.x via SNMPv3. It is possible that the template also works for SNMPv1/v2c, but I´ll not put any efforts in testing this (as there is no good reason not to use SNMPv3).
Alcatel-Lucent Enterprise OmniSwitch AOS Release 6.xThis template allows to monitor Alcatel-Lucent Enterprise OmniSwitch running AOS Release 6.x via SNMPv3. It is possible that the template also works for SNMPv1/v2c, but I´ll not put any efforts in testing this (as there is no good reason not to use SNMPv3 where it is available).
Alcatel Timetra TiMOS by SNMP
Macros used
| Name | Description | Default |
|---|---|---|
| {$TEMP_CRIT_LOW} | 5 |
|
| {$TEMP_CRIT} | 75 |
|
| {$TEMP_WARN} | 65 |
|
| {$PSU_CRIT_STATUS} | 4 |
|
| {$FAN_CRIT_STATUS} | 4 |
|
| {$MEMORY.UTIL.MAX} | 90 |
|
| {$CPU.UTIL.CRIT} | 90 |
|
| {$SNMP.TIMEOUT} | Time interval for the SNMP availability trigger. |
5m |
| {$ICMP_LOSS_WARN} | Warning threshold of ICMP packet loss in %. |
20 |
| {$ICMP_RESPONSE_TIME_WARN} | Warning threshold of the average ICMP response time in seconds. |
0.15 |
| {$IF.ERRORS.WARN} | Warning threshold of error packet rate. Can be used with interface name as context. |
2 |
| {$IF.UTIL.MAX} | 90 |
|
| {$IFCONTROL} | 1 |
|
| {$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
| {$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFADMINSTATUS.MATCHES} | ^.* |
|
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFDESCR.MATCHES} | .* |
|
| {$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFALIAS.MATCHES} | .* |
|
| {$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFTYPE.MATCHES} | .* |
|
| {$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| CPU utilization | MIB: TIMETRA-SYSTEM-MIB The value of sgiCpuUsage indicates the current CPU utilization for the system. |
SNMP agent | system.cpu.util[sgiCpuUsage.0] |
| Used memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryUsed indicates the total pre-allocated pool memory, in kilobytes, currently in use on the system. |
SNMP agent | vm.memory.used[sgiKbMemoryUsed.0] Preprocessing
|
| Available memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryAvailable indicates the amount of free memory, in kilobytes, in the overall system that is not allocated to memory pools, but is available in case a memory pool needs to grow. |
SNMP agent | vm.memory.available[sgiKbMemoryAvailable.0] Preprocessing
|
| Total memory | The total memory expressed in bytes. |
Calculated | vm.memory.total[snmp] |
| Memory utilization | Memory utilization in %. |
Calculated | vm.memory.util[vm.memory.util.0] |
| Hardware model name | MIB: SNMPv2-MIB |
SNMP agent | system.hw.model Preprocessing
|
| Operating system | MIB: SNMPv2-MIB |
SNMP agent | system.sw.os[sysDescr.0] Preprocessing
|
| Uptime (network) | MIB: SNMPv2-MIB Time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
| Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
| SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
| System location | MIB: SNMPv2-MIB Physical location of the node (e.g., |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
| System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
| System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
| System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
| System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
| SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible values: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
| ICMP ping | The host accessibility by ICMP ping. 0 - ICMP ping fails; 1 - ICMP ping successful. |
Simple check | icmpping |
| ICMP loss | The percentage of lost packets. |
Simple check | icmppingloss |
| ICMP response time | The ICMP ping response time (in seconds). |
Simple check | icmppingsec |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Alcatel Timetra TiMOS by SNMP/system.cpu.util[sgiCpuUsage.0],5m)>{$CPU.UTIL.CRIT} |
Warning | |
| Alcatel TiMOS: High memory utilization | The system is running out of free memory. |
min(/Alcatel Timetra TiMOS by SNMP/vm.memory.util[vm.memory.util.0],5m)>{$MEMORY.UTIL.MAX} |
Average | |
| Alcatel TiMOS: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0]))>0 |
Info | Manual close: Yes Depends on:
|
| Alcatel TiMOS: Host has been restarted | Uptime is less than 10 minutes. |
(last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Alcatel Timetra TiMOS by SNMP/system.net.uptime[sysUpTime.0])<10m) |
Warning | Manual close: Yes Depends on:
|
| Alcatel TiMOS: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.name,#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.name,#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.name))>0 |
Info | Manual close: Yes |
| Alcatel TiMOS: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Alcatel Timetra TiMOS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
| Alcatel TiMOS: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Alcatel Timetra TiMOS by SNMP/icmpping,#3)=0 |
High | |
| Alcatel TiMOS: High ICMP ping loss | ICMP packets loss detected. |
min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
| Alcatel TiMOS: High ICMP ping response time | Average ICMP response time is too high. |
avg(/Alcatel Timetra TiMOS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | SNMP agent | temperature.discovery |
Item prototypes for Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| {#SNMPVALUE}: Temperature | MIB: TIMETRA-SYSTEM-MIB The current temperature reading in degrees celsius from this hardware component's temperature sensor. If this component does not contain a temperature sensor, then the value -1 is returned. |
SNMP agent | sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}] |
Trigger prototypes for Temperature Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: {#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} |
Warning | Depends on:
|
| Alcatel TiMOS: {#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} |
High | |
| Alcatel TiMOS: {#SNMPVALUE}: Temperature is too low | avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average |
LLD rule FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPINDEX}: Fan status | MIB: TIMETRA-SYSTEM-MIB Current status of the Fan tray. |
SNMP agent | sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: #{#SNMPINDEX}: Fan is in critical state | Please check the fan unit |
count(/Alcatel Timetra TiMOS by SNMP/sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1 |
Average |
LLD rule PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| PSU Discovery | SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the first power supply in the tray (or shelf). For any other type, this represents the overall status of the power supply. If tmnxChassisPowerSupply1Status is'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP agent | sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}] |
| #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the second power supply in the tray (or shelf). For any other type, this field is unused and set to 'deviceNotEquipped'. If tmnxChassisPowerSupply2Status is 'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP agent | sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average | |
| Alcatel TiMOS: #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average |
LLD rule Entity Serial Numbers Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Entity Serial Numbers Discovery | SNMP agent | entity_sn.discovery |
Item prototypes for Entity Serial Numbers Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| {#ENT_NAME}: Hardware serial number | MIB: TIMETRA-CHASSIS-MIB |
SNMP agent | system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Entity Serial Numbers Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: {#ENT_NAME}: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}]))>0 |
Info | Manual close: Yes |
LLD rule Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Alcatel Timetra TiMOS by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Alcatel Timetra TiMOS by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Alcatel Timetra TiMOS by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Alcatel Timetra TiMOS by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
LLD rule EtherLike-MIB Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| EtherLike-MIB Discovery | Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered. |
SNMP agent | net.if.duplex.discovery Preprocessing
|
Item prototypes for EtherLike-MIB Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Duplex status | MIB: EtherLike-MIB The current mode of operation of the MAC entity. 'unknown' indicates that the current duplex mode could not be determined. Management control of the duplex mode is accomplished through the MAU MIB. When an interface does not support autonegotiation, or when autonegotiation is not enabled, the duplex mode is controlled using ifMauDefaultType. When autonegotiation is supported and enabled, duplex mode is controlled using ifMauAutoNegAdvertisedBits. In either case, the currently operating duplex mode is reflected both in this object and in ifMauType. Note that this object provides redundant information with ifMauType. Normally, redundant objects are discouraged. However, in this instance, it allows a management application to determine the duplex status of an interface without having to know every possible value of ifMauType. This was felt to be sufficiently valuable to justify the redundancy. Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus. |
SNMP agent | net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}] |
Trigger prototypes for EtherLike-MIB Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): In half-duplex mode | Please check autonegotiation settings and cabling. |
last(/Alcatel Timetra TiMOS by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2 |
Warning | Manual close: Yes |
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums
Alcatel Timetra TiMOS by SNMP
Macros used
| Name | Description | Default |
|---|---|---|
| {$TEMP_CRIT_LOW} | 5 |
|
| {$TEMP_CRIT} | 75 |
|
| {$TEMP_WARN} | 65 |
|
| {$PSU_CRIT_STATUS} | 4 |
|
| {$FAN_CRIT_STATUS} | 4 |
|
| {$MEMORY.UTIL.MAX} | 90 |
|
| {$CPU.UTIL.CRIT} | 90 |
|
| {$SNMP.TIMEOUT} | Time interval for the SNMP availability trigger. |
5m |
| {$ICMP_LOSS_WARN} | Warning threshold of ICMP packet loss in %. |
20 |
| {$ICMP_RESPONSE_TIME_WARN} | Warning threshold of the average ICMP response time in seconds. |
0.15 |
| {$IF.ERRORS.WARN} | Warning threshold of error packet rate. Can be used with interface name as context. |
2 |
| {$IF.UTIL.MAX} | 90 |
|
| {$IFCONTROL} | 1 |
|
| {$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
| {$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFADMINSTATUS.MATCHES} | ^.* |
|
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFDESCR.MATCHES} | .* |
|
| {$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFALIAS.MATCHES} | .* |
|
| {$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFTYPE.MATCHES} | .* |
|
| {$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| CPU utilization | MIB: TIMETRA-SYSTEM-MIB The value of sgiCpuUsage indicates the current CPU utilization for the system. |
SNMP agent | system.cpu.util[sgiCpuUsage.0] |
| Used memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryUsed indicates the total pre-allocated pool memory, in kilobytes, currently in use on the system. |
SNMP agent | vm.memory.used[sgiKbMemoryUsed.0] Preprocessing
|
| Available memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryAvailable indicates the amount of free memory, in kilobytes, in the overall system that is not allocated to memory pools, but is available in case a memory pool needs to grow. |
SNMP agent | vm.memory.available[sgiKbMemoryAvailable.0] Preprocessing
|
| Total memory | The total memory expressed in bytes. |
Calculated | vm.memory.total[snmp] |
| Memory utilization | Memory utilization in %. |
Calculated | vm.memory.util[vm.memory.util.0] |
| Hardware model name | MIB: SNMPv2-MIB |
SNMP agent | system.hw.model Preprocessing
|
| Operating system | MIB: SNMPv2-MIB |
SNMP agent | system.sw.os[sysDescr.0] Preprocessing
|
| Uptime (network) | MIB: SNMPv2-MIB Time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
| Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
| SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
| System location | MIB: SNMPv2-MIB Physical location of the node (e.g., |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
| System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
| System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
| System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
| System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
| SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible values: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
| ICMP ping | Simple check | icmpping | |
| ICMP loss | Simple check | icmppingloss | |
| ICMP response time | Simple check | icmppingsec |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Alcatel Timetra TiMOS by SNMP/system.cpu.util[sgiCpuUsage.0],5m)>{$CPU.UTIL.CRIT} |
Warning | |
| Alcatel TiMOS: High memory utilization | The system is running out of free memory. |
min(/Alcatel Timetra TiMOS by SNMP/vm.memory.util[vm.memory.util.0],5m)>{$MEMORY.UTIL.MAX} |
Average | |
| Alcatel TiMOS: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0]))>0 |
Info | Manual close: Yes Depends on:
|
| Alcatel TiMOS: Host has been restarted | Uptime is less than 10 minutes. |
(last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Alcatel Timetra TiMOS by SNMP/system.net.uptime[sysUpTime.0])<10m) |
Warning | Manual close: Yes Depends on:
|
| Alcatel TiMOS: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.name,#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.name,#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.name))>0 |
Info | Manual close: Yes |
| Alcatel TiMOS: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Alcatel Timetra TiMOS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
| Alcatel TiMOS: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Alcatel Timetra TiMOS by SNMP/icmpping,#3)=0 |
High | |
| Alcatel TiMOS: High ICMP ping loss | min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
|
| Alcatel TiMOS: High ICMP ping response time | Average ICMP response time is too high. |
avg(/Alcatel Timetra TiMOS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | SNMP agent | temperature.discovery |
Item prototypes for Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| {#SNMPVALUE}: Temperature | MIB: TIMETRA-SYSTEM-MIB The current temperature reading in degrees celsius from this hardware component's temperature sensor. If this component does not contain a temperature sensor, then the value -1 is returned. |
SNMP agent | sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}] |
Trigger prototypes for Temperature Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: {#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} |
Warning | Depends on:
|
| Alcatel TiMOS: {#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} |
High | |
| Alcatel TiMOS: {#SNMPVALUE}: Temperature is too low | avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average |
LLD rule FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPINDEX}: Fan status | MIB: TIMETRA-SYSTEM-MIB Current status of the Fan tray. |
SNMP agent | sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: #{#SNMPINDEX}: Fan is in critical state | Please check the fan unit |
count(/Alcatel Timetra TiMOS by SNMP/sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1 |
Average |
LLD rule PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| PSU Discovery | SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the first power supply in the tray (or shelf). For any other type, this represents the overall status of the power supply. If tmnxChassisPowerSupply1Status is'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP agent | sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}] |
| #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the second power supply in the tray (or shelf). For any other type, this field is unused and set to 'deviceNotEquipped'. If tmnxChassisPowerSupply2Status is 'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP agent | sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average | |
| Alcatel TiMOS: #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average |
LLD rule Entity Serial Numbers Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Entity Serial Numbers Discovery | SNMP agent | entity_sn.discovery |
Item prototypes for Entity Serial Numbers Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| {#ENT_NAME}: Hardware serial number | MIB: TIMETRA-CHASSIS-MIB |
SNMP agent | system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Entity Serial Numbers Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: {#ENT_NAME}: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}]))>0 |
Info | Manual close: Yes |
LLD rule Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Alcatel Timetra TiMOS by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Alcatel Timetra TiMOS by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Alcatel Timetra TiMOS by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Alcatel Timetra TiMOS by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
LLD rule EtherLike-MIB Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| EtherLike-MIB Discovery | Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered. |
SNMP agent | net.if.duplex.discovery Preprocessing
|
Item prototypes for EtherLike-MIB Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Duplex status | MIB: EtherLike-MIB The current mode of operation of the MAC entity. 'unknown' indicates that the current duplex mode could not be determined. Management control of the duplex mode is accomplished through the MAU MIB. When an interface does not support autonegotiation, or when autonegotiation is not enabled, the duplex mode is controlled using ifMauDefaultType. When autonegotiation is supported and enabled, duplex mode is controlled using ifMauAutoNegAdvertisedBits. In either case, the currently operating duplex mode is reflected both in this object and in ifMauType. Note that this object provides redundant information with ifMauType. Normally, redundant objects are discouraged. However, in this instance, it allows a management application to determine the duplex status of an interface without having to know every possible value of ifMauType. This was felt to be sufficiently valuable to justify the redundancy. Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus. |
SNMP agent | net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}] |
Trigger prototypes for EtherLike-MIB Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): In half-duplex mode | Please check autonegotiation settings and cabling. |
last(/Alcatel Timetra TiMOS by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2 |
Warning | Manual close: Yes |
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums
Alcatel Timetra TiMOS by SNMP
Macros used
| Name | Description | Default |
|---|---|---|
| {$TEMP_CRIT_LOW} | 5 |
|
| {$TEMP_CRIT} | 75 |
|
| {$TEMP_WARN} | 65 |
|
| {$PSU_CRIT_STATUS} | 4 |
|
| {$FAN_CRIT_STATUS} | 4 |
|
| {$MEMORY.UTIL.MAX} | 90 |
|
| {$CPU.UTIL.CRIT} | 90 |
|
| {$SNMP.TIMEOUT} | Time interval for the SNMP availability trigger. |
5m |
| {$ICMP_LOSS_WARN} | Warning threshold of ICMP packet loss in %. |
20 |
| {$ICMP_RESPONSE_TIME_WARN} | Warning threshold of the average ICMP response time in seconds. |
0.15 |
| {$IF.ERRORS.WARN} | Warning threshold of error packet rate. Can be used with interface name as context. |
2 |
| {$IF.UTIL.MAX} | 90 |
|
| {$IFCONTROL} | 1 |
|
| {$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
| {$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFADMINSTATUS.MATCHES} | ^.* |
|
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFDESCR.MATCHES} | .* |
|
| {$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFALIAS.MATCHES} | .* |
|
| {$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFTYPE.MATCHES} | .* |
|
| {$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| CPU utilization | MIB: TIMETRA-SYSTEM-MIB The value of sgiCpuUsage indicates the current CPU utilization for the system. |
SNMP agent | system.cpu.util[sgiCpuUsage.0] |
| Used memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryUsed indicates the total pre-allocated pool memory, in kilobytes, currently in use on the system. |
SNMP agent | vm.memory.used[sgiKbMemoryUsed.0] Preprocessing
|
| Available memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryAvailable indicates the amount of free memory, in kilobytes, in the overall system that is not allocated to memory pools, but is available in case a memory pool needs to grow. |
SNMP agent | vm.memory.available[sgiKbMemoryAvailable.0] Preprocessing
|
| Total memory | The total memory expressed in bytes. |
Calculated | vm.memory.total[snmp] |
| Memory utilization | Memory utilization in %. |
Calculated | vm.memory.util[vm.memory.util.0] |
| Hardware model name | MIB: SNMPv2-MIB |
SNMP agent | system.hw.model Preprocessing
|
| Operating system | MIB: SNMPv2-MIB |
SNMP agent | system.sw.os[sysDescr.0] Preprocessing
|
| Uptime (network) | MIB: SNMPv2-MIB Time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
| Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
| SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
| System location | MIB: SNMPv2-MIB Physical location of the node (e.g., |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
| System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
| System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
| System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
| System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
| SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible values: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
| ICMP ping | The host accessibility by ICMP ping. 0 - ICMP ping fails; 1 - ICMP ping successful. |
Simple check | icmpping |
| ICMP loss | The percentage of lost packets. |
Simple check | icmppingloss |
| ICMP response time | The ICMP ping response time (in seconds). |
Simple check | icmppingsec |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Alcatel Timetra TiMOS by SNMP/system.cpu.util[sgiCpuUsage.0],5m)>{$CPU.UTIL.CRIT} |
Warning | |
| Alcatel TiMOS: High memory utilization | The system is running out of free memory. |
min(/Alcatel Timetra TiMOS by SNMP/vm.memory.util[vm.memory.util.0],5m)>{$MEMORY.UTIL.MAX} |
Average | |
| Alcatel TiMOS: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0]))>0 |
Info | Manual close: Yes Depends on:
|
| Alcatel TiMOS: Host has been restarted | Uptime is less than 10 minutes. |
(last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Alcatel Timetra TiMOS by SNMP/system.net.uptime[sysUpTime.0])<10m) |
Warning | Manual close: Yes Depends on:
|
| Alcatel TiMOS: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.name,#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.name,#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.name))>0 |
Info | Manual close: Yes |
| Alcatel TiMOS: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Alcatel Timetra TiMOS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
| Alcatel TiMOS: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Alcatel Timetra TiMOS by SNMP/icmpping,#3)=0 |
High | |
| Alcatel TiMOS: High ICMP ping loss | ICMP packets loss detected. |
min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
| Alcatel TiMOS: High ICMP ping response time | Average ICMP response time is too high. |
avg(/Alcatel Timetra TiMOS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | SNMP agent | temperature.discovery |
Item prototypes for Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| {#SNMPVALUE}: Temperature | MIB: TIMETRA-SYSTEM-MIB The current temperature reading in degrees celsius from this hardware component's temperature sensor. If this component does not contain a temperature sensor, then the value -1 is returned. |
SNMP agent | sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}] |
Trigger prototypes for Temperature Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: {#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} |
Warning | Depends on:
|
| Alcatel TiMOS: {#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} |
High | |
| Alcatel TiMOS: {#SNMPVALUE}: Temperature is too low | avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average |
LLD rule FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPINDEX}: Fan status | MIB: TIMETRA-SYSTEM-MIB Current status of the Fan tray. |
SNMP agent | sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: #{#SNMPINDEX}: Fan is in critical state | Please check the fan unit |
count(/Alcatel Timetra TiMOS by SNMP/sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1 |
Average |
LLD rule PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| PSU Discovery | SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the first power supply in the tray (or shelf). For any other type, this represents the overall status of the power supply. If tmnxChassisPowerSupply1Status is'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP agent | sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}] |
| #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the second power supply in the tray (or shelf). For any other type, this field is unused and set to 'deviceNotEquipped'. If tmnxChassisPowerSupply2Status is 'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP agent | sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average | |
| Alcatel TiMOS: #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average |
LLD rule Entity Serial Numbers Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Entity Serial Numbers Discovery | SNMP agent | entity_sn.discovery |
Item prototypes for Entity Serial Numbers Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| {#ENT_NAME}: Hardware serial number | MIB: TIMETRA-CHASSIS-MIB |
SNMP agent | system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Entity Serial Numbers Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: {#ENT_NAME}: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}]))>0 |
Info | Manual close: Yes |
LLD rule Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Alcatel Timetra TiMOS by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Alcatel Timetra TiMOS by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Alcatel Timetra TiMOS by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Alcatel Timetra TiMOS by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
LLD rule EtherLike-MIB Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| EtherLike-MIB Discovery | Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered. |
SNMP agent | net.if.duplex.discovery Preprocessing
|
Item prototypes for EtherLike-MIB Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Duplex status | MIB: EtherLike-MIB The current mode of operation of the MAC entity. 'unknown' indicates that the current duplex mode could not be determined. Management control of the duplex mode is accomplished through the MAU MIB. When an interface does not support autonegotiation, or when autonegotiation is not enabled, the duplex mode is controlled using ifMauDefaultType. When autonegotiation is supported and enabled, duplex mode is controlled using ifMauAutoNegAdvertisedBits. In either case, the currently operating duplex mode is reflected both in this object and in ifMauType. Note that this object provides redundant information with ifMauType. Normally, redundant objects are discouraged. However, in this instance, it allows a management application to determine the duplex status of an interface without having to know every possible value of ifMauType. This was felt to be sufficiently valuable to justify the redundancy. Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus. |
SNMP agent | net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}] |
Trigger prototypes for EtherLike-MIB Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel TiMOS: Interface {#IFNAME}({#IFALIAS}): In half-duplex mode | Please check autonegotiation settings and cabling. |
last(/Alcatel Timetra TiMOS by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2 |
Warning | Manual close: Yes |
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums
Alcatel Timetra TiMOS by SNMP
Macros used
| Name | Description | Default |
|---|---|---|
| {$TEMP_CRIT_LOW} | 5 |
|
| {$TEMP_CRIT} | 75 |
|
| {$TEMP_WARN} | 65 |
|
| {$PSU_CRIT_STATUS} | 4 |
|
| {$FAN_CRIT_STATUS} | 4 |
|
| {$MEMORY.UTIL.MAX} | 90 |
|
| {$CPU.UTIL.CRIT} | 90 |
|
| {$SNMP.TIMEOUT} | 5m |
|
| {$ICMP_LOSS_WARN} | 20 |
|
| {$ICMP_RESPONSE_TIME_WARN} | 0.15 |
|
| {$IF.ERRORS.WARN} | 2 |
|
| {$IF.UTIL.MAX} | 90 |
|
| {$IFCONTROL} | 1 |
|
| {$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
| {$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFADMINSTATUS.MATCHES} | ^.* |
|
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFDESCR.MATCHES} | .* |
|
| {$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFALIAS.MATCHES} | .* |
|
| {$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFTYPE.MATCHES} | .* |
|
| {$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Alcatel Timetra TiMOS: CPU utilization | MIB: TIMETRA-SYSTEM-MIB The value of sgiCpuUsage indicates the current CPU utilization for the system. |
SNMP agent | system.cpu.util[sgiCpuUsage.0] |
| Alcatel Timetra TiMOS: Used memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryUsed indicates the total pre-allocated pool memory, in kilobytes, currently in use on the system. |
SNMP agent | vm.memory.used[sgiKbMemoryUsed.0] Preprocessing
|
| Alcatel Timetra TiMOS: Available memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryAvailable indicates the amount of free memory, in kilobytes, in the overall system that is not allocated to memory pools, but is available in case a memory pool needs to grow. |
SNMP agent | vm.memory.available[sgiKbMemoryAvailable.0] Preprocessing
|
| Alcatel Timetra TiMOS: Total memory | The total memory expressed in bytes. |
Calculated | vm.memory.total[snmp] |
| Alcatel Timetra TiMOS: Memory utilization | Memory utilization in %. |
Calculated | vm.memory.util[vm.memory.util.0] |
| Alcatel Timetra TiMOS: Hardware model name | MIB: SNMPv2-MIB |
SNMP agent | system.hw.model Preprocessing
|
| Alcatel Timetra TiMOS: Operating system | MIB: SNMPv2-MIB |
SNMP agent | system.sw.os[sysDescr.0] Preprocessing
|
| Alcatel Timetra TiMOS: Uptime (network) | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
| Alcatel Timetra TiMOS: Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
| Alcatel Timetra TiMOS: SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
| Alcatel Timetra TiMOS: System location | MIB: SNMPv2-MIB The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
| Alcatel Timetra TiMOS: System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
| Alcatel Timetra TiMOS: System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
| Alcatel Timetra TiMOS: System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
| Alcatel Timetra TiMOS: System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
| Alcatel Timetra TiMOS: SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible value: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
| Alcatel Timetra TiMOS: ICMP ping | Simple check | icmpping | |
| Alcatel Timetra TiMOS: ICMP loss | Simple check | icmppingloss | |
| Alcatel Timetra TiMOS: ICMP response time | Simple check | icmppingsec |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel Timetra TiMOS: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Alcatel Timetra TiMOS by SNMP/system.cpu.util[sgiCpuUsage.0],5m)>{$CPU.UTIL.CRIT} |
Warning | |
| Alcatel Timetra TiMOS: High memory utilization | The system is running out of free memory. |
min(/Alcatel Timetra TiMOS by SNMP/vm.memory.util[vm.memory.util.0],5m)>{$MEMORY.UTIL.MAX} |
Average | |
| Alcatel Timetra TiMOS: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0]))>0 |
Info | Manual close: Yes Depends on:
|
| Alcatel Timetra TiMOS: Host has been restarted | Uptime is less than 10 minutes. |
(last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Alcatel Timetra TiMOS by SNMP/system.net.uptime[sysUpTime.0])<10m) |
Warning | Manual close: Yes Depends on:
|
| Alcatel Timetra TiMOS: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.name,#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.name,#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.name))>0 |
Info | Manual close: Yes |
| Alcatel Timetra TiMOS: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Alcatel Timetra TiMOS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
| Alcatel Timetra TiMOS: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Alcatel Timetra TiMOS by SNMP/icmpping,#3)=0 |
High | |
| Alcatel Timetra TiMOS: High ICMP ping loss | min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
|
| Alcatel Timetra TiMOS: High ICMP ping response time | avg(/Alcatel Timetra TiMOS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | SNMP agent | temperature.discovery |
Item prototypes for Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| {#SNMPVALUE}: Temperature | MIB: TIMETRA-SYSTEM-MIB The current temperature reading in degrees celsius from this hardware component's temperature sensor. If this component does not contain a temperature sensor, then the value -1 is returned. |
SNMP agent | sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}] |
Trigger prototypes for Temperature Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| {#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} |
Warning | Depends on:
|
| {#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} |
High | |
| {#SNMPVALUE}: Temperature is too low | avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average |
LLD rule FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPINDEX}: Fan status | MIB: TIMETRA-SYSTEM-MIB Current status of the Fan tray. |
SNMP agent | sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| #{#SNMPINDEX}: Fan is in critical state | Please check the fan unit |
count(/Alcatel Timetra TiMOS by SNMP/sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1 |
Average |
LLD rule PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| PSU Discovery | SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the first power supply in the tray (or shelf). For any other type, this represents the overall status of the power supply. If tmnxChassisPowerSupply1Status is'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP agent | sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}] |
| #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the second power supply in the tray (or shelf). For any other type, this field is unused and set to 'deviceNotEquipped'. If tmnxChassisPowerSupply2Status is 'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP agent | sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average | |
| #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average |
LLD rule Entity Serial Numbers Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Entity Serial Numbers Discovery | SNMP agent | entity_sn.discovery |
Item prototypes for Entity Serial Numbers Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| {#ENT_NAME}: Hardware serial number | MIB: TIMETRA-CHASSIS-MIB |
SNMP agent | system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Entity Serial Numbers Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| {#ENT_NAME}: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}]))>0 |
Info | Manual close: Yes |
LLD rule Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
| Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Alcatel Timetra TiMOS by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Alcatel Timetra TiMOS by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
| Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Alcatel Timetra TiMOS by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Alcatel Timetra TiMOS by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
| Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
LLD rule EtherLike-MIB Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| EtherLike-MIB Discovery | Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered. |
SNMP agent | net.if.duplex.discovery Preprocessing
|
Item prototypes for EtherLike-MIB Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Duplex status | MIB: EtherLike-MIB The current mode of operation of the MAC entity. 'unknown' indicates that the current duplex mode could not be determined. Management control of the duplex mode is accomplished through the MAU MIB. When an interface does not support autonegotiation, or when autonegotiation is not enabled, the duplex mode is controlled using ifMauDefaultType. When autonegotiation is supported and enabled, duplex mode is controlled using ifMauAutoNegAdvertisedBits. In either case, the currently operating duplex mode is reflected both in this object and in ifMauType. Note that this object provides redundant information with ifMauType. Normally, redundant objects are discouraged. However, in this instance, it allows a management application to determine the duplex status of an interface without having to know every possible value of ifMauType. This was felt to be sufficiently valuable to justify the redundancy. Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus. |
SNMP agent | net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}] |
Trigger prototypes for EtherLike-MIB Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): In half-duplex mode | Please check autonegotiation settings and cabling |
last(/Alcatel Timetra TiMOS by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2 |
Warning | Manual close: Yes |
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums
Alcatel Timetra TiMOS by SNMP
Overview
For Zabbix version: 6.2 and higher.
Setup
Refer to the vendor documentation.
Zabbix configuration
No specific Zabbix configuration is required.
Macros used
| Name | Description | Default |
|---|---|---|
| {$CPU.UTIL.CRIT} | - |
90 |
| {$FAN_CRIT_STATUS} | - |
4 |
| {$ICMP_LOSS_WARN} | - |
20 |
| {$ICMP_RESPONSE_TIME_WARN} | - |
0.15 |
| {$IF.ERRORS.WARN} | - |
2 |
| {$IF.UTIL.MAX} | - |
90 |
| {$IFCONTROL} | - |
1 |
| {$MEMORY.UTIL.MAX} | - |
90 |
| {$NET.IF.IFADMINSTATUS.MATCHES} | Ignore notPresent(6) |
^.* |
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFALIAS.MATCHES} | - |
.* |
| {$NET.IF.IFALIAS.NOT_MATCHES} | - |
CHANGE_IF_NEEDED |
| {$NET.IF.IFDESCR.MATCHES} | - |
.* |
| {$NET.IF.IFDESCR.NOT_MATCHES} | - |
CHANGE_IF_NEEDED |
| {$NET.IF.IFNAME.MATCHES} | - |
^.*$ |
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
`(^Software Loopback Interface |
| {$NET.IF.IFOPERSTATUS.MATCHES} | - |
^.*$ |
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFTYPE.MATCHES} | - |
.* |
| {$NET.IF.IFTYPE.NOT_MATCHES} | - |
CHANGE_IF_NEEDED |
| {$PSU_CRIT_STATUS} | - |
4 |
| {$SNMP.TIMEOUT} | - |
5m |
| {$TEMP_CRIT_LOW} | - |
5 |
| {$TEMP_CRIT} | - |
75 |
| {$TEMP_WARN} | - |
65 |
Template links
There are no template links in this template.
Discovery rules
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Entity Serial Numbers Discovery | - |
SNMP | entity_sn.discovery Filter: AND- {#ENT_SN} MATCHES_REGEX |
| EtherLike-MIB Discovery | Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered. |
SNMP | net.if.duplex.discovery Preprocessing: - JAVASCRIPT: Filter: AND- {#IFOPERSTATUS} MATCHES_REGEX - {#SNMPVALUE} MATCHES_REGEX `(2 |
| FAN Discovery | - |
SNMP | fan.discovery Filter: AND_OR- {#SNMPVALUE} MATCHES_REGEX |
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP | net.if.discovery Filter: AND- {#IFADMINSTATUS} MATCHES_REGEX - {#IFADMINSTATUS} NOT_MATCHES_REGEX - {#IFOPERSTATUS} MATCHES_REGEX - {#IFOPERSTATUS} NOT_MATCHES_REGEX - {#IFNAME} MATCHES_REGEX - {#IFNAME} NOT_MATCHES_REGEX - {#IFDESCR} MATCHES_REGEX - {#IFDESCR} NOT_MATCHES_REGEX - {#IFALIAS} MATCHES_REGEX - {#IFALIAS} NOT_MATCHES_REGEX - {#IFTYPE} MATCHES_REGEX - {#IFTYPE} NOT_MATCHES_REGEX |
| PSU Discovery | - |
SNMP | psu.discovery |
| Temperature Discovery | - |
SNMP | temperature.discovery Filter: AND_OR- {#TEMP_SENSOR} MATCHES_REGEX |
Items collected
| Group | Name | Description | Type | Key and additional info |
|---|---|---|---|---|
| CPU | CPU utilization | MIB: TIMETRA-SYSTEM-MIB The value of sgiCpuUsage indicates the current CPU utilization for the system. |
SNMP | system.cpu.util[sgiCpuUsage.0] |
| Fans | #{#SNMPINDEX}: Fan status | MIB: TIMETRA-SYSTEM-MIB Current status of the Fan tray. |
SNMP | sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}] |
| General | SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP_TRAP | snmptrap.fallback |
| General | System location | MIB: SNMPv2-MIB The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. |
SNMP | system.location[sysLocation.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| General | System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP | system.contact[sysContact.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| General | System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP | system.objectid[sysObjectID.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| General | System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP | system.name Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| General | System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP | system.descr[sysDescr.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Inventory | Hardware model name | MIB: SNMPv2-MIB |
SNMP | system.hw.model Preprocessing: - REGEX: `^(\w |
| Inventory | Operating system | MIB: SNMPv2-MIB |
SNMP | system.sw.os[sysDescr.0] Preprocessing: - REGEX: `^((\w |
| Inventory | {#ENT_NAME}: Hardware serial number | MIB: TIMETRA-CHASSIS-MIB |
SNMP | system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Memory | Used memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryUsed indicates the total pre-allocated pool memory, in kilobytes, currently in use on the system. |
SNMP | vm.memory.used[sgiKbMemoryUsed.0] Preprocessing: - MULTIPLIER: |
| Memory | Available memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryAvailable indicates the amount of free memory, in kilobytes, in the overall system that is not allocated to memory pools, but is available in case a memory pool needs to grow. |
SNMP | vm.memory.available[sgiKbMemoryAvailable.0] Preprocessing: - MULTIPLIER: |
| Memory | Total memory | Total memory in Bytes. |
CALCULATED | vm.memory.total[snmp] Expression: last(//vm.memory.available[sgiKbMemoryAvailable.0])+last(//vm.memory.used[sgiKbMemoryUsed.0]) |
| Memory | Memory utilization | Memory utilization in %. |
CALCULATED | vm.memory.util[vm.memory.util.0] Expression: last(//vm.memory.used[sgiKbMemoryUsed.0])/(last(//vm.memory.available[sgiKbMemoryAvailable.0])+last(//vm.memory.used[sgiKbMemoryUsed.0]))*100 |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Duplex status | MIB: EtherLike-MIB The current mode of operation of the MAC entity. 'unknown' indicates that the current duplex mode could not be determined. Management control of the duplex mode is accomplished through the MAU MIB. When an interface does not support autonegotiation, or when autonegotiation is not enabled, the duplex mode is controlled using ifMauDefaultType. When autonegotiation is supported and enabled, duplex mode is controlled using ifMauAutoNegAdvertisedBits. In either case, the currently operating duplex mode is reflected both in this object and in ifMauType. Note that this object provides redundant information with ifMauType. Normally, redundant objects are discouraged. However, in this instance, it allows a management application to determine the duplex status of an interface without having to know every possible value of ifMauType. This was felt to be sufficiently valuable to justify the redundancy. Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus. |
SNMP | net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}] |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND - MULTIPLIER: |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND - MULTIPLIER: |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP | net.if.type[ifType.{#SNMPINDEX}] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Network interfaces | Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing: - MULTIPLIER: - DISCARD_UNCHANGED_HEARTBEAT: |
| Power supply | #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the first power supply in the tray (or shelf). For any other type, this represents the overall status of the power supply. If tmnxChassisPowerSupply1Status is'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP | sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}] |
| Power supply | #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the second power supply in the tray (or shelf). For any other type, this field is unused and set to 'deviceNotEquipped'. If tmnxChassisPowerSupply2Status is 'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP | sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}] |
| Status | Uptime (network) | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP | system.net.uptime[sysUpTime.0] Preprocessing: - MULTIPLIER: |
| Status | Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP | system.hw.uptime[hrSystemUptime.0] Preprocessing: - CHECK_NOT_SUPPORTED ⛔️ON_FAIL: - MULTIPLIER: |
| Status | SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible value: 0 - not available 1 - available 2 - unknown |
INTERNAL | zabbix[host,snmp,available] |
| Status | ICMP ping | - |
SIMPLE | icmpping |
| Status | ICMP loss | - |
SIMPLE | icmppingloss |
| Status | ICMP response time | - |
SIMPLE | icmppingsec |
| Temperature | {#SNMPVALUE}: Temperature | MIB: TIMETRA-SYSTEM-MIB The current temperature reading in degrees celsius from this hardware component's temperature sensor. If this component does not contain a temperature sensor, then the value -1 is returned. |
SNMP | sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}] |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| High CPU utilization | CPU utilization is too high. The system might be slow to respond. |
min(/Alcatel Timetra TiMOS by SNMP/system.cpu.util[sgiCpuUsage.0],5m)>{$CPU.UTIL.CRIT} |
WARNING | |
| #{#SNMPINDEX}: Fan is in critical state | Please check the fan unit |
count(/Alcatel Timetra TiMOS by SNMP/sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1 |
AVERAGE | |
| System name has changed | System name has changed. Ack to close. |
last(/Alcatel Timetra TiMOS by SNMP/system.name,#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.name,#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.name))>0 |
INFO | Manual close: YES |
| Operating system description has changed | Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close. |
last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0]))>0 |
INFO | Manual close: YES Depends on: - System name has changed |
| {#ENT_NAME}: Device has been replaced | Device serial number has changed. Ack to close |
last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}]))>0 |
INFO | Manual close: YES |
| High memory utilization | The system is running out of free memory. |
min(/Alcatel Timetra TiMOS by SNMP/vm.memory.util[vm.memory.util.0],5m)>{$MEMORY.UTIL.MAX} |
AVERAGE | |
| Interface {#IFNAME}({#IFALIAS}): In half-duplex mode | Please check autonegotiation settings and cabling |
last(/Alcatel Timetra TiMOS by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2 |
WARNING | Manual close: YES |
| Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: 1. Can be triggered if operations status is down. 2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down. 3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.) WARNING: if closed manually - won't fire again on next poll, because of .diff. |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))Recovery expression: last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0 |
AVERAGE | Manual close: YES |
| Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The network interface utilization is close to its estimated maximum bandwidth. |
(avg(/Alcatel Timetra TiMOS by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Alcatel Timetra TiMOS by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0Recovery expression: avg(/Alcatel Timetra TiMOS by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and avg(/Alcatel Timetra TiMOS by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) |
WARNING | Manual close: YES Depends on: - Interface {#IFNAME}({#IFALIAS}): Link down |
| Interface {#IFNAME}({#IFALIAS}): High error rate | Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold |
min(/Alcatel Timetra TiMOS by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Alcatel Timetra TiMOS by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}Recovery expression: max(/Alcatel Timetra TiMOS by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 and max(/Alcatel Timetra TiMOS by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 |
WARNING | Manual close: YES Depends on: - Interface {#IFNAME}({#IFALIAS}): Link down |
| Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close. |
change(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)Recovery expression: (change(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2) |
INFO | Manual close: YES Depends on: - Interface {#IFNAME}({#IFALIAS}): Link down |
| #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
AVERAGE | |
| #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
AVERAGE | |
| Host has been restarted | Uptime is less than 10 minutes. |
(last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Alcatel Timetra TiMOS by SNMP/system.net.uptime[sysUpTime.0])<10m) |
WARNING | Manual close: YES Depends on: - No SNMP data collection |
| No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Alcatel Timetra TiMOS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
WARNING | Depends on: - Unavailable by ICMP ping |
| Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Alcatel Timetra TiMOS by SNMP/icmpping,#3)=0 |
HIGH | |
| High ICMP ping loss | - |
min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)<100 |
WARNING | Depends on: - Unavailable by ICMP ping |
| High ICMP ping response time | - |
avg(/Alcatel Timetra TiMOS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
WARNING | Depends on: - High ICMP ping loss - Unavailable by ICMP ping |
| {#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}Recovery expression: max(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3 |
WARNING | Depends on: - {#SNMPVALUE}: Temperature is above critical threshold |
| {#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}Recovery expression: max(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3 |
HIGH | |
| {#SNMPVALUE}: Temperature is too low | - |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}Recovery expression: min(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3 |
AVERAGE |
Feedback
Please report any issues with the template at https://support.zabbix.com.
Alcatel Timetra TiMOS by SNMP
Macros used
| Name | Description | Default |
|---|---|---|
| {$TEMP_CRIT_LOW} | 5 |
|
| {$TEMP_CRIT} | 75 |
|
| {$TEMP_WARN} | 65 |
|
| {$PSU_CRIT_STATUS} | 4 |
|
| {$FAN_CRIT_STATUS} | 4 |
|
| {$MEMORY.UTIL.MAX} | 90 |
|
| {$CPU.UTIL.CRIT} | 90 |
|
| {$SNMP.TIMEOUT} | 5m |
|
| {$ICMP_LOSS_WARN} | 20 |
|
| {$ICMP_RESPONSE_TIME_WARN} | 0.15 |
|
| {$IF.ERRORS.WARN} | 2 |
|
| {$IF.UTIL.MAX} | 90 |
|
| {$IFCONTROL} | 1 |
|
| {$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
| {$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
| {$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
| {$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
| {$NET.IF.IFADMINSTATUS.MATCHES} | ^.* |
|
| {$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
| {$NET.IF.IFDESCR.MATCHES} | .* |
|
| {$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFALIAS.MATCHES} | .* |
|
| {$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
| {$NET.IF.IFTYPE.MATCHES} | .* |
|
| {$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Alcatel Timetra TiMOS: CPU utilization | MIB: TIMETRA-SYSTEM-MIB The value of sgiCpuUsage indicates the current CPU utilization for the system. |
SNMP agent | system.cpu.util[sgiCpuUsage.0] |
| Alcatel Timetra TiMOS: Used memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryUsed indicates the total pre-allocated pool memory, in kilobytes, currently in use on the system. |
SNMP agent | vm.memory.used[sgiKbMemoryUsed.0] Preprocessing
|
| Alcatel Timetra TiMOS: Available memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryAvailable indicates the amount of free memory, in kilobytes, in the overall system that is not allocated to memory pools, but is available in case a memory pool needs to grow. |
SNMP agent | vm.memory.available[sgiKbMemoryAvailable.0] Preprocessing
|
| Alcatel Timetra TiMOS: Total memory | The total memory expressed in bytes. |
Calculated | vm.memory.total[snmp] |
| Alcatel Timetra TiMOS: Memory utilization | Memory utilization in %. |
Calculated | vm.memory.util[vm.memory.util.0] |
| Alcatel Timetra TiMOS: Hardware model name | MIB: SNMPv2-MIB |
SNMP agent | system.hw.model Preprocessing
|
| Alcatel Timetra TiMOS: Operating system | MIB: SNMPv2-MIB |
SNMP agent | system.sw.os[sysDescr.0] Preprocessing
|
| Alcatel Timetra TiMOS: Uptime (network) | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
| Alcatel Timetra TiMOS: Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
| Alcatel Timetra TiMOS: SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
| Alcatel Timetra TiMOS: System location | MIB: SNMPv2-MIB The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
| Alcatel Timetra TiMOS: System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
| Alcatel Timetra TiMOS: System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
| Alcatel Timetra TiMOS: System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
| Alcatel Timetra TiMOS: System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
| Alcatel Timetra TiMOS: SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible value: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
| Alcatel Timetra TiMOS: ICMP ping | Simple check | icmpping | |
| Alcatel Timetra TiMOS: ICMP loss | Simple check | icmppingloss | |
| Alcatel Timetra TiMOS: ICMP response time | Simple check | icmppingsec |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Alcatel Timetra TiMOS: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Alcatel Timetra TiMOS by SNMP/system.cpu.util[sgiCpuUsage.0],5m)>{$CPU.UTIL.CRIT} |
Warning | |
| Alcatel Timetra TiMOS: High memory utilization | The system is running out of free memory. |
min(/Alcatel Timetra TiMOS by SNMP/vm.memory.util[vm.memory.util.0],5m)>{$MEMORY.UTIL.MAX} |
Average | |
| Alcatel Timetra TiMOS: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.sw.os[sysDescr.0]))>0 |
Info | Manual close: Yes Depends on:
|
| Alcatel Timetra TiMOS: Host has been restarted | Uptime is less than 10 minutes. |
(last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Alcatel Timetra TiMOS by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Alcatel Timetra TiMOS by SNMP/system.net.uptime[sysUpTime.0])<10m) |
Warning | Manual close: Yes Depends on:
|
| Alcatel Timetra TiMOS: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.name,#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.name,#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.name))>0 |
Info | Manual close: Yes |
| Alcatel Timetra TiMOS: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Alcatel Timetra TiMOS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
| Alcatel Timetra TiMOS: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Alcatel Timetra TiMOS by SNMP/icmpping,#3)=0 |
High | |
| Alcatel Timetra TiMOS: High ICMP ping loss | min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Alcatel Timetra TiMOS by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
|
| Alcatel Timetra TiMOS: High ICMP ping response time | avg(/Alcatel Timetra TiMOS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | SNMP agent | temperature.discovery |
Item prototypes for Temperature Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| {#SNMPVALUE}: Temperature | MIB: TIMETRA-SYSTEM-MIB The current temperature reading in degrees celsius from this hardware component's temperature sensor. If this component does not contain a temperature sensor, then the value -1 is returned. |
SNMP agent | sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}] |
Trigger prototypes for Temperature Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| {#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} |
Warning | Depends on:
|
| {#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} |
High | |
| {#SNMPVALUE}: Temperature is too low | avg(/Alcatel Timetra TiMOS by SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average |
LLD rule FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| FAN Discovery | SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPINDEX}: Fan status | MIB: TIMETRA-SYSTEM-MIB Current status of the Fan tray. |
SNMP agent | sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| #{#SNMPINDEX}: Fan is in critical state | Please check the fan unit |
count(/Alcatel Timetra TiMOS by SNMP/sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1 |
Average |
LLD rule PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| PSU Discovery | SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the first power supply in the tray (or shelf). For any other type, this represents the overall status of the power supply. If tmnxChassisPowerSupply1Status is'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP agent | sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}] |
| #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the second power supply in the tray (or shelf). For any other type, this field is unused and set to 'deviceNotEquipped'. If tmnxChassisPowerSupply2Status is 'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP agent | sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average | |
| #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS by SNMP/sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average |
LLD rule Entity Serial Numbers Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Entity Serial Numbers Discovery | SNMP agent | entity_sn.discovery |
Item prototypes for Entity Serial Numbers Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| {#ENT_NAME}: Hardware serial number | MIB: TIMETRA-CHASSIS-MIB |
SNMP agent | system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Entity Serial Numbers Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| {#ENT_NAME}: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#2) and length(last(/Alcatel Timetra TiMOS by SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}]))>0 |
Info | Manual close: Yes |
LLD rule Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
| Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
| Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
| Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Alcatel Timetra TiMOS by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Alcatel Timetra TiMOS by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
| Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Alcatel Timetra TiMOS by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Alcatel Timetra TiMOS by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
| Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Alcatel Timetra TiMOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Alcatel Timetra TiMOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Alcatel Timetra TiMOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
LLD rule EtherLike-MIB Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| EtherLike-MIB Discovery | Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered. |
SNMP agent | net.if.duplex.discovery Preprocessing
|
Item prototypes for EtherLike-MIB Discovery
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): Duplex status | MIB: EtherLike-MIB The current mode of operation of the MAC entity. 'unknown' indicates that the current duplex mode could not be determined. Management control of the duplex mode is accomplished through the MAU MIB. When an interface does not support autonegotiation, or when autonegotiation is not enabled, the duplex mode is controlled using ifMauDefaultType. When autonegotiation is supported and enabled, duplex mode is controlled using ifMauAutoNegAdvertisedBits. In either case, the currently operating duplex mode is reflected both in this object and in ifMauType. Note that this object provides redundant information with ifMauType. Normally, redundant objects are discouraged. However, in this instance, it allows a management application to determine the duplex status of an interface without having to know every possible value of ifMauType. This was felt to be sufficiently valuable to justify the redundancy. Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus. |
SNMP agent | net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}] |
Trigger prototypes for EtherLike-MIB Discovery
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| Interface {#IFNAME}({#IFALIAS}): In half-duplex mode | Please check autonegotiation settings and cabling |
last(/Alcatel Timetra TiMOS by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2 |
Warning | Manual close: Yes |
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums
Alcatel Timetra TiMOS SNMP
Overview
For Zabbix version: 5.4 and higher
Setup
Refer to the vendor documentation.
Zabbix configuration
No specific Zabbix configuration is required.
Macros used
| Name | Description | Default |
|---|---|---|
| {$CPU.UTIL.CRIT} | - |
90 |
| {$FAN_CRIT_STATUS} | - |
4 |
| {$MEMORY.UTIL.MAX} | - |
90 |
| {$PSU_CRIT_STATUS} | - |
4 |
| {$TEMP_CRIT_LOW} | - |
5 |
| {$TEMP_CRIT} | - |
75 |
| {$TEMP_WARN} | - |
65 |
Template links
| Name |
|---|
| EtherLike-MIB SNMP |
| Generic SNMP |
| Interfaces SNMP |
Discovery rules
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | - |
SNMP | temperature.discovery Filter: AND_OR- {#TEMP_SENSOR} MATCHES_REGEX |
| FAN Discovery | - |
SNMP | fan.discovery Filter: AND_OR- {#SNMPVALUE} MATCHES_REGEX |
| PSU Discovery | - |
SNMP | psu.discovery |
| Entity Serial Numbers Discovery | - |
SNMP | entity_sn.discovery Filter: AND- {#ENT_SN} MATCHES_REGEX |
Items collected
| Group | Name | Description | Type | Key and additional info |
|---|---|---|---|---|
| CPU | CPU utilization | MIB: TIMETRA-SYSTEM-MIB The value of sgiCpuUsage indicates the current CPU utilization for the system. |
SNMP | system.cpu.util[sgiCpuUsage.0] |
| Fans | #{#SNMPINDEX}: Fan status | MIB: TIMETRA-SYSTEM-MIB Current status of the Fan tray. |
SNMP | sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}] |
| Inventory | Hardware model name | MIB: SNMPv2-MIB |
SNMP | system.hw.model Preprocessing: - REGEX: `^(\w |
| Inventory | Operating system | MIB: SNMPv2-MIB |
SNMP | system.sw.os[sysDescr.0] Preprocessing: - REGEX: `^((\w |
| Inventory | {#ENT_NAME}: Hardware serial number | MIB: TIMETRA-CHASSIS-MIB |
SNMP | system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Memory | Used memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryUsed indicates the total pre-allocated pool memory, in kilobytes, currently in use on the system. |
SNMP | vm.memory.used[sgiKbMemoryUsed.0] Preprocessing: - MULTIPLIER: |
| Memory | Available memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryAvailable indicates the amount of free memory, in kilobytes, in the overall system that is not allocated to memory pools, but is available in case a memory pool needs to grow. |
SNMP | vm.memory.available[sgiKbMemoryAvailable.0] Preprocessing: - MULTIPLIER: |
| Memory | Total memory | Total memory in Bytes |
CALCULATED | vm.memory.total[snmp] Expression: last(//vm.memory.available[sgiKbMemoryAvailable.0])+last(//vm.memory.used[sgiKbMemoryUsed.0]) |
| Memory | Memory utilization | Memory utilization in % |
CALCULATED | vm.memory.util[vm.memory.util.0] Expression: last(//vm.memory.used[sgiKbMemoryUsed.0])/(last(//vm.memory.available[sgiKbMemoryAvailable.0])+last(//vm.memory.used[sgiKbMemoryUsed.0]))*100 |
| Power_supply | #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple powersupplies, this represents the overall status of the first power supplyin the tray (or shelf). For any other type, this represents the overall status of the power supply. If tmnxChassisPowerSupply1Status is'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP | sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}] |
| Power_supply | #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple powersupplies, this represents the overall status of the second power supplyin the tray (or shelf). For any other type, this field is unused and set to 'deviceNotEquipped'. If tmnxChassisPowerSupply2Status is 'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP | sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}] |
| Temperature | {#SNMPVALUE}: Temperature | MIB: TIMETRA-SYSTEM-MIB The current temperature reading in degrees celsius from this hardware component's temperature sensor. If this component does not contain a temperature sensor, then the value -1 is returned. |
SNMP | sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}] |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m) | CPU utilization is too high. The system might be slow to respond. |
min(/Alcatel Timetra TiMOS SNMP/system.cpu.util[sgiCpuUsage.0],5m)>{$CPU.UTIL.CRIT} |
WARNING | |
| #{#SNMPINDEX}: Fan is in critical state | Please check the fan unit |
count(/Alcatel Timetra TiMOS SNMP/sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1 |
AVERAGE | |
| Operating system description has changed | Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close. |
last(/Alcatel Timetra TiMOS SNMP/system.sw.os[sysDescr.0],#1)<>last(/Alcatel Timetra TiMOS SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Alcatel Timetra TiMOS SNMP/system.sw.os[sysDescr.0]))>0 |
INFO | Manual close: YES |
| {#ENT_NAME}: Device has been replaced (new serial number received) | Device serial number has changed. Ack to close |
last(/Alcatel Timetra TiMOS SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#1)<>last(/Alcatel Timetra TiMOS SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}],#2) and length(last(/Alcatel Timetra TiMOS SNMP/system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}]))>0 |
INFO | Manual close: YES |
| High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m) | The system is running out of free memory. |
min(/Alcatel Timetra TiMOS SNMP/vm.memory.util[vm.memory.util.0],5m)>{$MEMORY.UTIL.MAX} |
AVERAGE | |
| #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS SNMP/sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
AVERAGE | |
| #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Alcatel Timetra TiMOS SNMP/sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
AVERAGE | |
| {#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:""} | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:""}Recovery expression: max(/Alcatel Timetra TiMOS SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3 |
WARNING | Depends on: - {#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:""} |
| {#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:""} | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Alcatel Timetra TiMOS SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}Recovery expression: max(/Alcatel Timetra TiMOS SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3 |
HIGH | |
| {#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:""} | - |
avg(/Alcatel Timetra TiMOS SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}Recovery expression: min(/Alcatel Timetra TiMOS SNMP/sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3 |
AVERAGE |
Feedback
Please report any issues with the template at https://support.zabbix.com
Template Net Alcatel Timetra TiMOS SNMP
Overview
For Zabbix version: 5.0 and higher
Setup
Refer to the vendor documentation.
Zabbix configuration
No specific Zabbix configuration is required.
Macros used
| Name | Description | Default |
|---|---|---|
| {$CPU.UTIL.CRIT} | - |
90 |
| {$FAN_CRIT_STATUS} | - |
4 |
| {$MEMORY.UTIL.MAX} | - |
90 |
| {$PSU_CRIT_STATUS} | - |
4 |
| {$TEMP_CRIT_LOW} | - |
5 |
| {$TEMP_CRIT} | - |
75 |
| {$TEMP_WARN} | - |
65 |
Template links
| Name |
|---|
| EtherLike-MIB SNMP |
| Generic SNMP |
| Interfaces SNMP |
Discovery rules
| Name | Description | Type | Key and additional info |
|---|---|---|---|
| Temperature Discovery | - |
SNMP | temperature.discovery Filter: AND_OR- A: {#TEMP_SENSOR} MATCHES_REGEX |
| FAN Discovery | - |
SNMP | fan.discovery Filter: AND_OR- A: {#SNMPVALUE} MATCHES_REGEX |
| PSU Discovery | - |
SNMP | psu.discovery |
| Entity Serial Numbers Discovery | - |
SNMP | entity_sn.discovery Filter: AND- B: {#ENT_SN} MATCHES_REGEX |
Items collected
| Group | Name | Description | Type | Key and additional info |
|---|---|---|---|---|
| CPU | CPU utilization | MIB: TIMETRA-SYSTEM-MIB The value of sgiCpuUsage indicates the current CPU utilization for the system. |
SNMP | system.cpu.util[sgiCpuUsage.0] |
| Fans | #{#SNMPINDEX}: Fan status | MIB: TIMETRA-SYSTEM-MIB Current status of the Fan tray. |
SNMP | sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}] |
| Inventory | Hardware model name | MIB: SNMPv2-MIB |
SNMP | system.hw.model Preprocessing: - REGEX: `^(\w |
| Inventory | Operating system | MIB: SNMPv2-MIB |
SNMP | system.sw.os[sysDescr.0] Preprocessing: - REGEX: `^((\w |
| Inventory | {#ENT_NAME}: Hardware serial number | MIB: TIMETRA-CHASSIS-MIB |
SNMP | system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
| Memory | Used memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryUsed indicates the total pre-allocated pool memory, in kilobytes, currently in use on the system. |
SNMP | vm.memory.used[sgiKbMemoryUsed.0] Preprocessing: - MULTIPLIER: |
| Memory | Available memory | MIB: TIMETRA-SYSTEM-MIB The value of sgiKbMemoryAvailable indicates the amount of free memory, in kilobytes, in the overall system that is not allocated to memory pools, but is available in case a memory pool needs to grow. |
SNMP | vm.memory.available[sgiKbMemoryAvailable.0] Preprocessing: - MULTIPLIER: |
| Memory | Total memory | Total memory in Bytes. |
CALCULATED | vm.memory.total[snmp] Expression: last("vm.memory.available[sgiKbMemoryAvailable.0]")+last("vm.memory.used[sgiKbMemoryUsed.0]") |
| Memory | Memory utilization | Memory utilization in %. |
CALCULATED | vm.memory.util[vm.memory.util.0] Expression: last("vm.memory.used[sgiKbMemoryUsed.0]")/(last("vm.memory.available[sgiKbMemoryAvailable.0]")+last("vm.memory.used[sgiKbMemoryUsed.0]"))*100 |
| Power_supply | #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the first power supply in the tray (or shelf). For any other type, this represents the overall status of the power supply. If tmnxChassisPowerSupply1Status is'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP | sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}] |
| Power_supply | #{#SNMPINDEX}: Power supply status | MIB: TIMETRA-SYSTEM-MIB The overall status of an equipped power supply. For AC multiple power supplies, this represents the overall status of the second power supply in the tray (or shelf). For any other type, this field is unused and set to 'deviceNotEquipped'. If tmnxChassisPowerSupply2Status is 'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A value of 'deviceStateFailed' represents a condition where at least one monitored status is in a failed state. |
SNMP | sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}] |
| Temperature | {#SNMPVALUE}: Temperature | MIB: TIMETRA-SYSTEM-MIB The current temperature reading in degrees celsius from this hardware component's temperature sensor. If this component does not contain a temperature sensor, then the value -1 is returned. |
SNMP | sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}] |
Triggers
| Name | Description | Expression | Severity | Dependencies and additional info |
|---|---|---|---|---|
| High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m) | CPU utilization is too high. The system might be slow to respond. |
{TEMPLATE_NAME:system.cpu.util[sgiCpuUsage.0].min(5m)}>{$CPU.UTIL.CRIT} |
WARNING | |
| #{#SNMPINDEX}: Fan is in critical state | Please check the fan unit |
{TEMPLATE_NAME:sensor.fan.status[tmnxChassisFanOperStatus.{#SNMPINDEX}].count(#1,{$FAN_CRIT_STATUS},eq)}=1 |
AVERAGE | |
| Operating system description has changed | Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close. |
{TEMPLATE_NAME:system.sw.os[sysDescr.0].diff()}=1 and {TEMPLATE_NAME:system.sw.os[sysDescr.0].strlen()}>0 |
INFO | Manual close: YES |
| {#ENT_NAME}: Device has been replaced (new serial number received) | Device serial number has changed. Ack to close |
{TEMPLATE_NAME:system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}].diff()}=1 and {TEMPLATE_NAME:system.hw.serialnumber[tmnxHwSerialNumber.{#SNMPINDEX}].strlen()}>0 |
INFO | Manual close: YES |
| High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m) | The system is running out of free memory. |
{TEMPLATE_NAME:vm.memory.util[vm.memory.util.0].min(5m)}>{$MEMORY.UTIL.MAX} |
AVERAGE | |
| #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
{TEMPLATE_NAME:sensor.psu.status[tmnxChassisPowerSupply1Status.{#SNMPINDEX}].count(#1,{$PSU_CRIT_STATUS},eq)}=1 |
AVERAGE | |
| #{#SNMPINDEX}: Power supply is in critical state | Please check the power supply unit for errors |
{TEMPLATE_NAME:sensor.psu.status[tmnxChassisPowerSupply2Status.{#SNMPINDEX}].count(#1,{$PSU_CRIT_STATUS},eq)}=1 |
AVERAGE | |
| {#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:""} | This trigger uses temperature sensor values as well as temperature sensor status if available |
{TEMPLATE_NAME:sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}].avg(5m)}>{$TEMP_WARN:""}Recovery expression: {TEMPLATE_NAME:sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}].max(5m)}<{$TEMP_WARN:""}-3 |
WARNING | Depends on: - {#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:""} |
| {#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:""} | This trigger uses temperature sensor values as well as temperature sensor status if available |
{TEMPLATE_NAME:sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}].avg(5m)}>{$TEMP_CRIT:""}Recovery expression: {TEMPLATE_NAME:sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}].max(5m)}<{$TEMP_CRIT:""}-3 |
HIGH | |
| {#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:""} | - |
{TEMPLATE_NAME:sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}].avg(5m)}<{$TEMP_CRIT_LOW:""}Recovery expression: {TEMPLATE_NAME:sensor.temp.value[tmnxHwTemperature.{#SNMPINDEX}].min(5m)}>{$TEMP_CRIT_LOW:""}+3 |
AVERAGE |
Feedback
Please report any issues with the template at https://support.zabbix.com