Brocade FC by SNMP
Overview
For Zabbix version: 6.4 and higher. https://community.brocade.com/dtscp75322/attachments/dtscp75322/fibre/25235/1/FOS_MIB_Reference_v740.pdf
This template was tested on:
- Brocade 6520, version v7.4.1c
- Brocade 300, version v7.0.0c
- Brocade BL 5480, version v6.3.1c
Setup
Refer to the vendor documentation.
Zabbix configuration
No specific Zabbix configuration is required.
Macros used
Name | Description | Default |
---|---|---|
{$CPU.UTIL.CRIT} | - |
90 |
{$FAN_CRIT_STATUS} | - |
2 |
{$FAN_OK_STATUS} | - |
4 |
{$HEALTH_CRIT_STATUS} | - |
4 |
{$HEALTH_WARN_STATUS:"offline"} | - |
2 |
{$HEALTH_WARN_STATUS:"testing"} | - |
3 |
{$ICMP_LOSS_WARN} | - |
20 |
{$ICMP_RESPONSE_TIME_WARN} | - |
0.15 |
{$IF.ERRORS.WARN} | - |
2 |
{$IF.UTIL.MAX} | - |
90 |
{$IFCONTROL} | - |
1 |
{$MEMORY.UTIL.MAX} | - |
90 |
{$NET.IF.IFADMINSTATUS.MATCHES} | Ignore notPresent(6) |
^.* |
{$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
{$NET.IF.IFALIAS.MATCHES} | - |
.* |
{$NET.IF.IFALIAS.NOT_MATCHES} | - |
CHANGE_IF_NEEDED |
{$NET.IF.IFDESCR.MATCHES} | - |
.* |
{$NET.IF.IFDESCR.NOT_MATCHES} | - |
CHANGE_IF_NEEDED |
{$NET.IF.IFNAME.MATCHES} | - |
^.*$ |
{$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
(^Software Loopback Interface|^NULL[0-9.]*$|^[Ll]o[0-9.]*$|^[Ss]ystem$|^Nu[0-9.]*$|^veth[0-9a-z]+$|docker[0-9]+|br-[a-z0-9]{12}) |
{$NET.IF.IFOPERSTATUS.MATCHES} | - |
^.*$ |
{$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
{$NET.IF.IFTYPE.MATCHES} | - |
.* |
{$NET.IF.IFTYPE.NOT_MATCHES} | - |
CHANGE_IF_NEEDED |
{$PSU_CRIT_STATUS} | - |
2 |
{$PSU_OK_STATUS} | - |
4 |
{$SNMP.TIMEOUT} | - |
5m |
{$TEMP_CRIT_LOW} | - |
5 |
{$TEMP_CRIT} | - |
75 |
{$TEMP_WARN_STATUS} | - |
5 |
{$TEMP_WARN} | - |
65 |
Template links
There are no template links in this template.
Discovery rules
Name | Description | Type | Key and additional info |
---|---|---|---|
FAN Discovery | - |
SNMP | fan.discovery Filter: AND_OR- {#SENSOR_TYPE} MATCHES_REGEX |
Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP | net.if.discovery Filter: AND- {#IFADMINSTATUS} MATCHES_REGEX - {#IFADMINSTATUS} NOT_MATCHES_REGEX - {#IFOPERSTATUS} MATCHES_REGEX - {#IFOPERSTATUS} NOT_MATCHES_REGEX - {#IFNAME} MATCHES_REGEX - {#IFNAME} NOT_MATCHES_REGEX - {#IFDESCR} MATCHES_REGEX - {#IFDESCR} NOT_MATCHES_REGEX - {#IFALIAS} MATCHES_REGEX - {#IFALIAS} NOT_MATCHES_REGEX - {#IFTYPE} MATCHES_REGEX - {#IFTYPE} NOT_MATCHES_REGEX |
PSU Discovery | - |
SNMP | psu.discovery Filter: AND_OR- {#SENSOR_TYPE} MATCHES_REGEX |
Temperature Discovery | - |
SNMP | temperature.discovery Filter: AND_OR- {#SENSOR_TYPE} MATCHES_REGEX |
Items collected
Group | Name | Description | Type | Key and additional info |
---|---|---|---|---|
CPU | CPU utilization | MIB: SW-MIB System's CPU usage. |
SNMP | system.cpu.util[swCpuUsage.0] |
Fans | {#SENSOR_INFO}: Fan status | MIB: SW-MIB |
SNMP | sensor.fan.status[swSensorStatus.{#SNMPINDEX}] |
Fans | {#SENSOR_INFO}: Fan speed | MIB: SW-MIB The current value (reading) of the sensor. The value, -2147483648, represents an unknown quantity. The fan value will be in RPM(revolution per minute) |
SNMP | sensor.fan.speed[swSensorValue.{#SNMPINDEX}] |
General | SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP_TRAP | snmptrap.fallback |
General | System location | MIB: SNMPv2-MIB The physical location of this node (e.g., |
||
General | System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP | system.contact[sysContact.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
General | System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
||
General | System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP | system.name Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
General | System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP | system.descr[sysDescr.0] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
Inventory | Hardware serial number | MIB: SW-MIB |
SNMP | system.hw.serialnumber Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
Inventory | Firmware version | MIB: SW-MIB |
SNMP | system.hw.firmware Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
Memory | Memory utilization | MIB: SW-MIB Memory utilization in %. |
SNMP | vm.memory.util[swMemUsage.0] |
Network interfaces | Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP | net.if.status[ifOperStatus.{#SNMPINDEX}] |
Network interfaces | Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND - MULTIPLIER: |
Network interfaces | Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND - MULTIPLIER: |
Network interfaces | Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND |
Network interfaces | Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND |
Network interfaces | Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND |
Network interfaces | Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing: - CHANGE_PER_SECOND |
Network interfaces | Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP | net.if.type[ifType.{#SNMPINDEX}] Preprocessing: - DISCARD_UNCHANGED_HEARTBEAT: |
Network interfaces | Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
||
Power supply | {#SENSOR_INFO}: Power supply status | MIB: SW-MIB |
SNMP | sensor.psu.status[swSensorStatus.{#SNMPINDEX}] |
Status | Overall system health status | MIB: SW-MIB The current operational status of the switch.The states are as follow: online(1) means the switch is accessible by an external Fibre Channel port offline(2) means the switch is not accessible testing(3) means the switch is in a built-in test mode and is not accessible by an external Fibre Channel port faulty(4) means the switch is not operational. |
SNMP | system.status[swOperStatus.0] |
Status | Uptime (network) | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP | system.net.uptime[sysUpTime.0] Preprocessing: - MULTIPLIER: |
Status | Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP | system.hw.uptime[hrSystemUptime.0] Preprocessing: - CHECK_NOT_SUPPORTED ⛔️ON_FAIL: - MULTIPLIER: |
Status | SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible value: 0 - not available 1 - available 2 - unknown |
INTERNAL | zabbix[host,snmp,available] |
Status | ICMP ping | - |
SIMPLE | icmpping |
Status | ICMP loss | - |
SIMPLE | icmppingloss |
Status | ICMP response time | - |
SIMPLE | icmppingsec |
Temperature | {#SENSOR_INFO}: Temperature | MIB: SW-MIB Temperature readings of testpoint: {#SENSOR_INFO} |
SNMP | sensor.temp.value[swSensorValue.{#SNMPINDEX}] |
Temperature | {#SENSOR_INFO}: Temperature status | MIB: SW-MIB Temperature status of testpoint: {#SENSOR_INFO} |
SNMP | sensor.temp.status[swSensorStatus.{#SNMPINDEX}] |
Triggers
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
High CPU utilization | CPU utilization is too high. The system might be slow to respond. |
min(/Brocade FC by SNMP/system.cpu.util[swCpuUsage.0],5m)>{$CPU.UTIL.CRIT} |
WARNING | |
{#SENSOR_INFO}: Fan is in critical state | Please check the fan unit |
count(/Brocade FC by SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1 |
AVERAGE | |
{#SENSOR_INFO}: Fan is not in normal state | Please check the fan unit |
count(/Brocade FC by SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1 |
INFO | Depends on: - {#SENSOR_INFO}: Fan is in critical state |
System name has changed | System name has changed. Ack to close. |
last(/Brocade FC by SNMP/system.name,#1)<>last(/Brocade FC by SNMP/system.name,#2) and length(last(/Brocade FC by SNMP/system.name))>0 |
INFO | Manual close: YES |
Device has been replaced | Device serial number has changed. Ack to close |
last(/Brocade FC by SNMP/system.hw.serialnumber,#1)<>last(/Brocade FC by SNMP/system.hw.serialnumber,#2) and length(last(/Brocade FC by SNMP/system.hw.serialnumber))>0 |
INFO | Manual close: YES |
Firmware has changed | Firmware version has changed. Ack to close |
last(/Brocade FC by SNMP/system.hw.firmware,#1)<>last(/Brocade FC by SNMP/system.hw.firmware,#2) and length(last(/Brocade FC by SNMP/system.hw.firmware))>0 |
INFO | Manual close: YES |
High memory utilization | The system is running out of free memory. |
min(/Brocade FC by SNMP/vm.memory.util[swMemUsage.0],5m)>{$MEMORY.UTIL.MAX} |
AVERAGE | |
Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: 1. Can be triggered if operations status is down. 2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down. 3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.) WARNING: if closed manually - won't fire again on next poll, because of .diff. |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) Recovery expression: last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0 |
AVERAGE | Manual close: YES |
Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The network interface utilization is close to its estimated maximum bandwidth. |
(avg(/Brocade FC by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Brocade FC by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 Recovery expression: avg(/Brocade FC by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and avg(/Brocade FC by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) |
WARNING | Manual close: YES Depends on: - Interface {#IFNAME}({#IFALIAS}): Link down |
Interface {#IFNAME}({#IFALIAS}): High error rate | Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold |
min(/Brocade FC by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Brocade FC by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} Recovery expression: max(/Brocade FC by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 and max(/Brocade FC by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 |
WARNING | Manual close: YES Depends on: - Interface {#IFNAME}({#IFALIAS}): Link down |
Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close. |
change(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) Recovery expression: (change(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2) |
INFO | Manual close: YES Depends on: - Interface {#IFNAME}({#IFALIAS}): Link down |
{#SENSOR_INFO}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Brocade FC by SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
AVERAGE | |
{#SENSOR_INFO}: Power supply is not in normal state | Please check the power supply unit for errors |
count(/Brocade FC by SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1 |
INFO | Depends on: - {#SENSOR_INFO}: Power supply is in critical state |
System status is in critical state | Please check the device for errors |
count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_CRIT_STATUS}")=1 |
HIGH | |
System status is in warning state | Please check the device for warnings |
count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_WARN_STATUS:\"offline\"}")=1 or count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_WARN_STATUS:\"testing\"}")=1 |
WARNING | Depends on: - System status is in critical state |
Host has been restarted | Uptime is less than 10 minutes. |
(last(/Brocade FC by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Brocade FC by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Brocade FC by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Brocade FC by SNMP/system.net.uptime[sysUpTime.0])<10m) |
WARNING | Manual close: YES Depends on: - No SNMP data collection |
No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Brocade FC by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
WARNING | Depends on: - Unavailable by ICMP ping |
Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Brocade FC by SNMP/icmpping,#3)=0 |
HIGH | |
High ICMP ping loss | - |
min(/Brocade FC by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Brocade FC by SNMP/icmppingloss,5m)<100 |
WARNING | Depends on: - Unavailable by ICMP ping |
High ICMP ping response time | - |
avg(/Brocade FC by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
WARNING | Depends on: - High ICMP ping loss - Unavailable by ICMP ping |
{#SENSOR_INFO}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_INFO}"} or last(/Brocade FC by SNMP/sensor.temp.status[swSensorStatus.{#SNMPINDEX}])={$TEMP_WARN_STATUS} Recovery expression: max(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_INFO}"}-3 |
WARNING | Depends on: - {#SENSOR_INFO}: Temperature is above critical threshold |
{#SENSOR_INFO}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_INFO}"} Recovery expression: max(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_INFO}"}-3 |
HIGH | |
{#SENSOR_INFO}: Temperature is too low | - |
avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"} Recovery expression: min(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}+3 |
AVERAGE |
Feedback
Please report any issues with the template at https://support.zabbix.com.
Known Issues
- Description: no IF-MIB::ifAlias is available
- Version: v6.3.1c, v7.0.0c, v7.4.1c
- Device: all