Available solutions


Zabbix community templates

5 Contributed to the zabbix/community-templates repository
community-templates / template_raritan_px_pdu

Works with Raritan PDU PX2 / PX3 and ATS PX3 productsDiscovery rules:InletsOutletsOvercurrent ProtectorsSensorsWith advanced power function (See https://www.zabbix.com/forum/zabbix-help/385574 for more info)

Zabbix 5.0+ eric_at_2037
2025 1 y ago
5
community-templates / template_legrand_cs_121

Template for monitoring UPS Legrand CS 121 (all models) with explanations and advices. The mibs are there: http://ups.legrand.com/software/The content of template:5 Applications: General, Health, Input, Output, Battery18 Items:Input voltage, Battery Status ,Estimated minutes remaining if no power , Bypass VoltageAlarms present on {HOST.NAME}, Bypass Current, Bypass PowerInput line bads, Output Power, Output load in percentSeconds on battery, Output VoltageEstimated charge remaining, Battery voltageBattery temperature, Device VersionDevice Name, Device Model13 Triggers and 4 GraphsThe template use SNMP agent v2. Assure that you set the community in template macros.Assure also that in Administration -> General -> Value mapping you have under APC Battery Status next values1 ⇒ unknown2 ⇒ batteryNormal3 ⇒ batteryLow4 ⇒ batteryDepleted

Zabbix 5.0+ Tudor Ticau
2022 5 y ago
3
community-templates / template_legrand_cs-121_multiphase_auto_discovery

Template for monitoring UPS Legrand CS 121 (all models) with explanations and advices. The mibs are there: http://ups.legrand.com/software/The content of template:5 Applications: General, Health, Input, Output, Battery18 Items:Input voltage, Battery Status ,Estimated minutes remaining if no power , Bypass VoltageAlarms present on {HOST.NAME}, Bypass Current, Bypass PowerInput line bads, Output Power, Output load in percentSeconds on battery, Output VoltageEstimated charge remaining, Battery voltageBattery temperature, Device VersionDevice Name, Device Model13 Triggers and 4 GraphsThe template use SNMP agent v2. Assure that you set the community in template macros.Assure also that in Administration -> General -> Value mapping you have under APC Battery Status next values1 ⇒ unknown2 ⇒ batteryNormal3 ⇒ batteryLow4 ⇒ batteryDepletedSend me what template you need, or if this template helped you, you can buy me one coffee :)Upgraded template from Tudor Ticau

Zabbix 5.0+ Dusan Priechodsky
2022 5 y ago
3
community-templates / template_legrand_cs-141_multiphase_auto_discovery

Template for monitoring UPS Legrand CS 141 (all models) with explanations and advices. The mibs are there: http://ups.legrand.com/software/The content of template:5 Applications: General, Health, Input, Output, Battery18 Items:Input voltage, Battery Status ,Estimated minutes remaining if no power , Bypass VoltageAlarms present on {HOST.NAME}, Bypass Current, Bypass PowerInput line bads, Output Power, Output load in percentSeconds on battery, Output VoltageEstimated charge remaining, Battery voltageBattery temperature, Device VersionDevice Name, Device Model13 Triggers and 4 GraphsThe template use SNMP agent v2. Assure that you set the community in template macros.Assure also that in Administration -> General -> Value mapping you have under APC Battery Status next values1 ⇒ unknown2 ⇒ batteryNormal3 ⇒ batteryLow4 ⇒ batteryDepletedSend me what template you need, or if this template helped you, you can buy me one coffee :)Upgraded template from Tudor Ticau

Zabbix 5.0+ Dusan Priechodsky
2022 5 y ago
3
community-templates / template_raritan_pdu_px3

Zabbix monitoring template for Raritan PDU PX3-5466RThis template was tested only on Zabbix 4.4 and PX3-5466R devices but may work on other models too. The sensor discovery is simplistic and many assumptions were made, which might require little changes to make it work on other models.The discovery rules are set to 1 minute interval and the discovered items are also set to 1 minute interval in order to allow quick tests. For real deployments you should create your own template, link this template to your own template and override the discovery intervals with values that make sense for you. For example, we use 1 day interval for the discovery rules because our power topology is pretty static and once the first discovery is done there is no need to keep discovery rules running often.The triggers are defined based on the sensor states in order to respect the thresholds defined in each PDU, and for that reason the actual PDU thresholds don´t show in the graphs.Suggestions and corrections are welcome, see https://github.com/BrandwatchLtd/zabbix-templates/tree/master/raritan-pdu-px3Inspired in the Raritan PX PDU template

Zabbix 5.0+ Tiago TT
2022 5 y ago
3

See all Zabbix community templates

Articles and documentation

+ Propose new article

Didn't find what you are looking for?