Hi,Here is a template for HP PDU´sThere are mostly traps items but also some polling items.SNMPv2.Triggers are also include.You need to put your SNMP community in macro.Thanks.
Monitor power parametrs: frequency, power, voltage, current, temp. Full control for Input, Output (Segment), Battery, Bypass. I used CPQPOWER1.76.MIB and UPS-MIB.mib
Zabbix template wher added some parametrs like this:Printer door openPrinter Jam presentCartridge supply percentCartridge supply remaining print pageShows Printer web pageShows printer model7.Shows printer supply model and name.Printer statusI hope this template will helpfull for You.
Template for HP A5120 switch with SNMP v3 authPriv.Included items:CPU usageMemory usageTemperatureFan statusPSU sensorDevice name, location, description, contact detailsDiscovery rule for CRC errorsno links to other templates, does not include standard interface items (use generic SNMP interface template)I use SNMP V3 with authPriv security level, SHA authentication protocol, AES privacy protocol.It is required to fill these variables with correct values using host macros.Security name: {$SNMP_V3_USER}Authentication passphrase: {$SNMP_V3_AUTHPASSPHRASE}Privacy passphrase: {$SNMP_V3_PRIVPASSPHRASE}Created on Zabbix 3.0, should work with newer/older versions.
Tested on HPE_3PAR 8450, HPE_3PAR 20840_R2Python-script to get metrics from HP 3Par Storage. Script uses SMI-S interface.This script get next metrics:Battery, CagePowerSupply, DiskDrive, DriveCage, DynamicStoragePool, EthernetPort, Fan, FCPort, IDEDrive, NodePowerSupply, NodeSystem, PCICard, PhysicalMemory, SASPort
This template expanded the original 24 ports template to 48 ports published by Павел Яковлев and made compatible with Zabbix 2.0.x+It is necessary to set:{$SNMP_COMMUNITY} - public is the default value for read-only and private for read-write.{$SNMP_PORT} - The value 161 is the default for SNMP port.The template was tested in Zabbix:2.0.62.2.7
This templates monitors the HP iLO100i integrated lights-out system for available sensors.Tested only on Zabbix 4.2.x with a iLO100i, possibly working on other iLOs aswell.You need to configure the IPMI-Tab on any monitored host with a Username and Password. These can be set in the User Administration of the iLO-Card and only need "User" rights.There are no triggers configured, alerts should be handled specifically for your own setup!
Simple template to monitor ipmi hp DL380p G9 server by ipmi protocol by iLO interface.useful with my hp ipmi Drives discovery templatePlease first corretly configure ipmi interface on node in zabbix web interface.This pack contains template: IPMI HP DL380p Gen9 without Drives.xml - contains all sensors except hard drives I prefer use template with noHDD option and my ipmi HDD discovery template.
simple template to monitor IPMI sensors for HP blade server BL460G8
IPMI Template for the HP XL420 Gen 9
Low Level Discovery (LLD) for HP transceivers (switches) monitoring (gbic DDM DDMI DOM).Attention: You will want to have a regular expression called @isFiberTransceiver to filter out cooper gbics (stacking, etc)oid .1.3.6.1.4.1.25506.2.70.1.1.1.1Triggers are created with thresholds given by gbic.Temperature, voltage, bias, serial, hardware type, fiber diameter, status, dbm, db, transmit power, receive power.
Tested with Zabbix 4.03 on HP OfficeJet Pro 8710
SNMPV2Works on Office Connect Switches191019201950Low Level Discovery for:CPUFan StatusInterfaces (Ports) - includes Rx/Tx/Errors/StatusMac AddressMemory StatsPSUTempature SensorsEntity - includes Serial Number, Model Name, Firmware, Hardware revision, OS
Version: 4 (04.04.2018)*+ 24 HDD (*Enclosure 1) HW status (SMART, media errors, bad sectors) and triggersSupported models: 2312fc, p2000, 2040 SAN (2050 - works in progress)Language: Russian onlyFeatures:No external apps\scriptsNo LLDTelnet (you can use SSH instead, but telnet is really quicker)Regex (to get raw response from device or for pre-cleaning data for XPath)2-step preprocessing (xPath & regex)Components health state\ operational statusBasic performance and statusInstallation:Import this TemplateCreate two macro (at every device if all accounts are different or in template itself if accounts are equal):{$SAN_LOGIN} with CLI Login{$SAN_PASSWD} with CLI PasswordNow you have 1 new Template:[Шаблон] TELNET - HP StorageWorks"And several new value mappings:HP (StorageWorks) Blame StateHP (StorageWorks) Component HealthHP (StorageWorks) Controller IDHP (StorageWorks) Controller LocationHP (StorageWorks) Controller StatusHP (StorageWorks) Enclosure StatusHP (StorageWorks) Failover StateHP (StorageWorks) HDD LED StatusHP (StorageWorks) Job NameHP (StorageWorks) Port StatusHP (StorageWorks) PSU LocationHP (StorageWorks) StatusHP (StorageWorks) VDISK StatusI tried to create all Keys of Items in most understood look. If you will have questions with understanding of Ites´s names.All Applications of higher level are contain information about quantity of subcomponents.So:App "Storage" contains the number of the connected EnclosuresApp "Enclosure" contains the number of disks slots and installed physical disksApp "Controllers" contains the number of the vdisksApp "Virt(ual). disks" contains the number of the physical disks, used in vdisks and nuber of VolumesBy default, all source XML Items for all basic subsystems are enabled ("XML" application).By default, only basic set of dependent Items is enabled. For getting data from 1 basic Storage (without expansions):1 disks enclosure2 controllers (A.B)4 FC ports (A1,B1,A2,B2)2 PSUs (left, right)1 physical disk (first in enclosure)1 virtual disk (first on controller A)versions of main components
It is a simple template to monitoring *HP ILO ProLiant DL380p Gen8.*It controls the status about fans, disks, RAM banks, CPUs and temperature sensors.It is tested with the Zabbix version 4 alpha and works properly.Federico
Template for HP servers with iLO 5 controller.Tested on ProLiant DL360 Gen10 with firmware version = 1.40 Feb 05 2019You must add one macro on the server or on the template with the name:{$SNMP_COMMUNITY} with the community to be usedAll the items was created with "SNMPv2 agent"Make sure your iLO is reachable from the zabbix server/proxy, test with:snmpstatus -v 2c -c public 192.168.0.1Based on @Wisenetman iLO 4 template
PMI HW status [Health, Drives, Fan, Power, Temperature, Temperature Memory], Triggers [Health, Drives, Temperature, Power, Fans]
Displays informations (Ink usage, another information) graths and triggers on low toner levels, printheads.
Based on the C7000 Chassis template by Vladimir Marakshin.This has been updated to work with Zabbix 4.2. It has had some Russian changed to English, and added the Onboard Administrators to the discovery rule. It also only discovers device bays that have a device in them.Note that this template required the HP/CPQ MIBs, and still does. It does not use numeric OIDs.The MIB files can be downloaded from HPE. This link worked to reach the MIB Kit when this was uploaded:https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-c04272529At least the cpqhost.mib and cpqrack.mib MIBs must be installed in your Zabbix server/proxy (the host that executes the SNMP checks). On a CentOS/RHEL system, that is in /usr/share/snmp/mibs. After they are installed, the Zabbix server/proxy must be restarted.See the Github project for more recent versions.https://github.com/lweeks/zabbix_hp_c7000
Template for SW 5100 with GBIC.GBIC Information:Optical signal levelLaser TemperatureVoltage and Current in the LaserWavelengthManufacturerRequired to MIB:HH3C-TRANSCEIVER-INFO-MIB
Modified (added additional ports) following template HP 1920-16G
Modified and updated(CPU and Memory monitor) version of the Zabbix 2.2 HP V1910 SNMP template
Beta TolkitPosh for 3par-7200 monitorigPlease contact with questions in the mail or telegramПросьба обращаться с вопросами в почту или telegramFor multiple unique problems with host windows and powershell 3par toolkit HPE. I´m going to redo everything under linux Until the end of 2018, I´m going to have timeI apologize for not informative in use, I deliberately raised the threshold of entry so that no one would destroy the data in the storage systemПо многочисленным и уникальным проблемам с хостами windows и powershell 3par toolkit HPE. Я собираюсь переделать все под linux. До конца 2018 года собираюсь успетьПрошу прощения за не информативность в использовании, я намеренно повысил порог вхождения чтоб никто не уничтожил данные в СХДhttps://github.com/Toh3mi/zabbix-3parmail [email protected] @toh3mi
Switch 26 portsMonitoring on Speed, Portstatus, Last Changed, In and Out Throughput and number of errors.Graphs for IN and OUT throughput per portAdapted from the layout https://www.zabbix.com/forum/attachment.php?attachmentid=4762&d=1337691484
Template para monitorar o Switch 3COM, modelo 4500 de 28 portas.Gráficos por porta, Entrada e Saída, Erro de tráfego nas 28 portas.O template exibe a alteração e status da porta.O template foi criado por: Marcelo Carvalho eu fiz somente a edição.
HiHere is a template for HP MCSMostly traps.Triggers included.Thanks
Check for:controller, cache, battery* health;logical volumes health;physical drives health and temperature**;auto-discovery and agentd-side send data procedure.