Source: https://git.zabbix.com/projects/ZBX/repos/zabbix/browse/templates/server/dell/dell_r840_snmp
This is a template for monitoring DELL PowerEdge R840 servers with iDRAC version 7 and later via Zabbix SNMP agent that works without any external scripts.
Zabbix version: 7.2 and higher.
This template has been tested on:
Zabbix should be configured according to the instructions in the Templates out of the box section.
Refer to the vendor documentation.
Name | Description | Default |
---|---|---|
{$SENSOR.TEMP.STATUS.OK} | The OK status of the temperature probe for trigger expression. |
3 |
{$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} | The warning status of the temperature probe for trigger expression. |
4 |
{$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"} | The warning status of the temperature probe for trigger expression. |
7 |
{$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} | The critical status of the temperature probe for trigger expression. |
5 |
{$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} | The critical status of the temperature probe for trigger expression. |
6 |
{$SENSOR.TEMP.STATUS.CRIT:"criticalLower"} | The critical status of the temperature probe for trigger expression. |
8 |
{$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"} | The critical status of the temperature probe for trigger expression. |
9 |
{$HEALTH.STATUS.DISASTER} | The disaster status of the health for trigger expression. |
6 |
{$HEALTH.STATUS.CRIT} | The critical status of the health for trigger expression. |
5 |
{$HEALTH.STATUS.WARN} | The warning status of the health for trigger expression. |
4 |
{$PSU.STATUS.WARN:"nonCritical"} | The warning value of the PSU sensor for trigger expression. |
4 |
{$PSU.STATUS.CRIT:"critical"} | The critical value of the PSU sensor for trigger expression. |
5 |
{$PSU.STATUS.CRIT:"nonRecoverable"} | The critical value of the PSU sensor for trigger expression. |
6 |
{$FAN.STATUS.WARN:"nonCriticalUpper"} | The warning value of the FAN sensor for trigger expression. |
4 |
{$FAN.STATUS.WARN:"nonCriticalLower"} | The warning value of the FAN sensor for trigger expression. |
7 |
{$FAN.STATUS.CRIT:"criticalUpper"} | The critical value of the FAN sensor for trigger expression. |
5 |
{$FAN.STATUS.CRIT:"nonRecoverableUpper"} | The critical value of the FAN sensor for trigger expression. |
6 |
{$FAN.STATUS.CRIT:"criticalLower"} | The critical value of the FAN sensor for trigger expression. |
8 |
{$FAN.STATUS.CRIT:"nonRecoverableLower"} | The critical value of the FAN sensor for trigger expression. |
9 |
{$FAN.STATUS.CRIT:"failed"} | The critical value of the FAN sensor for trigger expression. |
10 |
{$DISK.ARRAY.STATUS.FAIL} | The disaster status of the disk array for trigger expression. |
6 |
{$DISK.ARRAY.STATUS.CRIT} | The critical status of the disk array for trigger expression. |
5 |
{$DISK.ARRAY.STATUS.WARN} | The warning status of the disk array for trigger expression. |
4 |
{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT} | The critical status of the disk array cache battery for trigger expression. |
3 |
{$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN} | The warning status of the disk array cache battery for trigger expression. |
4 |
{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK} | The OK status of the disk array cache battery for trigger expression. |
2 |
{$VDISK.STATUS.CRIT:"failed"} | The critical status of the virtual disk for trigger expression. |
3 |
{$VDISK.STATUS.WARN:"degraded"} | The warning status of the virtual disk for trigger expression. |
4 |
{$DISK.STATUS.WARN:"nonCritical"} | The warning status of the disk for trigger expression. |
4 |
{$DISK.STATUS.FAIL:"critical"} | The critical status of the disk for trigger expression. |
5 |
{$DISK.STATUS.FAIL:"nonRecoverable"} | The critical status of the disk for trigger expression. |
6 |
{$DISK.SMART.STATUS.FAIL} | The critical S.M.A.R.T status of the disk for trigger expression. |
1 |
{$SNMP.TIMEOUT} | The time interval for SNMP agent availability trigger expression. |
5m |
Name | Description | Type | Key and additional info |
---|---|---|---|
Overall system health status | MIB: IDRAC-MIB-SMIv2 This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc. |
SNMP agent | dell.server.status[globalSystemStatus] Preprocessing
|
Hardware model name | MIB: IDRAC-MIB-SMIv2 This attribute defines the model name of the system. |
SNMP agent | dell.server.hw.model[systemModelName] Preprocessing
|
Hardware serial number | MIB: IDRAC-MIB-SMIv2 This attribute defines the service tag of the system. |
SNMP agent | dell.server.hw.serialnumber[systemServiceTag] Preprocessing
|
Operating system | MIB: IDRAC-MIB-SMIv2 This attribute defines the name of the operating system that the host is running. |
SNMP agent | dell.server.sw.os[systemOSName] Preprocessing
|
Firmware version | MIB: IDRAC-MIB-SMIv2 This attribute defines the firmware version of a remote access card. |
SNMP agent | dell.server.hw.firmware[racFirmwareVersion] Preprocessing
|
Uptime (network) | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | dell.server.net.uptime[sysUpTime] Preprocessing
|
Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | dell.server.hw.uptime[hrSystemUptime] Preprocessing
|
SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
System location | MIB: SNMPv2-MIB The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. |
SNMP agent | dell.server.location[sysLocation] Preprocessing
|
System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | dell.server.contact[sysContact] Preprocessing
|
System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining 'what kind of box' is being managed. For example, if vendor 'Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its 'Fred Router'. |
SNMP agent | dell.server.objectid[sysObjectID] Preprocessing
|
System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | dell.server.name[sysName] Preprocessing
|
System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | dell.server.descr[sysDescr] Preprocessing
|
SNMP agent availability | Zabbix internal | zabbix[host,snmp,available] Preprocessing
|
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
DELL PowerEdge R840: System is in unrecoverable state | Please check the device for faults. |
last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.DISASTER} |
Disaster | |
DELL PowerEdge R840: System status is in critical state | Please check the device for errors. |
last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.CRIT} |
High | |
DELL PowerEdge R840: System status is in warning state | Please check the device for warnings. |
last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.WARN} |
Warning | Depends on:
|
DELL PowerEdge R840: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0 |
Info | Manual close: Yes |
DELL PowerEdge R840: Operating system description has changed | Operating system description has changed. Possibly, the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/DELL PowerEdge R840 by SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.sw.os[systemOSName]))>0 |
Info | Manual close: Yes |
DELL PowerEdge R840: Firmware has changed | Firmware version has changed. Acknowledge to close the problem manually. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0 |
Info | Manual close: Yes |
DELL PowerEdge R840: Host has been restarted | Uptime is less than 10 minutes. |
(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.uptime[hrSystemUptime])>0 and last(/DELL PowerEdge R840 by SNMP/dell.server.hw.uptime[hrSystemUptime])<10m) or (last(/DELL PowerEdge R840 by SNMP/dell.server.hw.uptime[hrSystemUptime])=0 and last(/DELL PowerEdge R840 by SNMP/dell.server.net.uptime[sysUpTime])<10m) |
Warning | Manual close: Yes |
DELL PowerEdge R840: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/DELL PowerEdge R840 by SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.name[sysName]))>0 |
Info | Manual close: Yes |
DELL PowerEdge R840: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/DELL PowerEdge R840 by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning |
Name | Description | Type | Key and additional info |
---|---|---|---|
Temperature discovery | Scanning table of Temperature Probe Table IDRAC-MIB-SMIv2::temperatureProbeTable |
SNMP agent | temp.discovery Preprocessing
|
Name | Description | Type | Key and additional info |
---|---|---|---|
{#SENSOR_LOCALE} Value | MIB: IDRAC-MIB-SMIv2 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the value returned for this attribute is the temperature that the probe is reading in Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. |
SNMP agent | dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}] Preprocessing
|
{#SENSOR_LOCALE} Status | MIB: IDRAC-MIB-SMIv2 This attribute defines the probe status of the temperature probe. Possible values: other(1), -- probe status is not one of the following: unknown(2), -- probe status is unknown (not known or monitored) ok(3), -- probe is reporting a value within the thresholds nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold criticalUpper(5), -- probe has crossed the upper critical threshold nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold nonCriticalLower(7), -- probe has crossed the lower noncritical threshold criticalLower(8), -- probe has crossed the lower critical threshold nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold failed(10) -- probe is not functional |
SNMP agent | dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}] Preprocessing
|
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
DELL PowerEdge R840: Probe {#SENSOR_LOCALE} is in critical status | Please check the device for faults. |
last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"} |
Average | |
DELL PowerEdge R840: Probe {#SENSOR_LOCALE} is in warning status | Please check the device for faults. |
last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"} |
Warning | Depends on:
|
DELL PowerEdge R840: Probe {#SENSOR_LOCALE} is not in optimal status | Please check the device for faults. |
last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$SENSOR.TEMP.STATUS.OK} |
Info | Manual close: Yes Depends on:
|
Name | Description | Type | Key and additional info |
---|---|---|---|
PSU discovery | IDRAC-MIB-SMIv2::powerSupplyTable |
SNMP agent | psu.discovery Preprocessing
|
Name | Description | Type | Key and additional info |
---|---|---|---|
{#PSU_DESCR} | MIB: IDRAC-MIB-SMIv2 0600.0012.0001.0005 This attribute defines the status of the power supply. |
SNMP agent | dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}] Preprocessing
|
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
DELL PowerEdge R840: Power supply {#PSU_DESCR} is in critical state | Please check the power supply unit for errors. |
last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"nonRecoverable"} |
Average | |
DELL PowerEdge R840: Power supply {#PSU_DESCR} is in warning state | Please check the power supply unit for errors. |
last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.WARN:"nonCritical"} |
Warning | Depends on:
|
Name | Description | Type | Key and additional info |
---|---|---|---|
FAN discovery | IDRAC-MIB-SMIv2::coolingDeviceTable |
SNMP agent | fan.discovery Preprocessing
|
Name | Description | Type | Key and additional info |
---|---|---|---|
{#FAN_DESCR} Status | MIB: IDRAC-MIB-SMIv2 This attribute defines the probe status of the cooling device. |
SNMP agent | dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}] Preprocessing
|
{#FAN_DESCR} Speed | MIB: IDRAC-MIB-SMIv2 This attribute defines the reading for a cooling device of subtype other than coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute. |
SNMP agent | dell.server.sensor.fan.speed[coolingDeviceReading.{#SNMPINDEX}] |
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
DELL PowerEdge R840: {#FAN_DESCR} is in critical state | Please check the fan unit. |
last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"failed"} |
Average | |
DELL PowerEdge R840: {#FAN_DESCR} is in warning state | Please check the fan unit. |
last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalLower"} |
Warning | Depends on:
|
Name | Description | Type | Key and additional info |
---|---|---|---|
Array controller discovery | Scanning table of Array controllers: IDRAC-MIB-SMIv2::controllerTable |
SNMP agent | array.discovery Preprocessing
|
Name | Description | Type | Key and additional info |
---|---|---|---|
{#CNTLR_NAME} Status | MIB: IDRAC-MIB-SMIv2 The status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable |
SNMP agent | dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}] Preprocessing
|
{#CNTLR_NAME} Model | MIB: IDRAC-MIB-SMIv2 The controller's name as represented in Storage Management. |
SNMP agent | dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}] Preprocessing
|
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
DELL PowerEdge R840: {#CNTLR_NAME} is in unrecoverable state | Please check the device for faults. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.FAIL} |
Disaster | |
DELL PowerEdge R840: {#CNTLR_NAME} is in critical state | Please check the device for faults. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT} |
High | Depends on:
|
DELL PowerEdge R840: {#CNTLR_NAME} is in warning state | Please check the device for faults. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN} |
Average | Depends on:
|
Name | Description | Type | Key and additional info |
---|---|---|---|
Array controller cache discovery | Scanning table of Array controllers: IDRAC-MIB-SMIv2::batteryTable |
SNMP agent | array.cache.discovery Preprocessing
|
Name | Description | Type | Key and additional info |
---|---|---|---|
{#BATTERY_NAME} Status | MIB: IDRAC-MIB-SMIv2 Current state of battery. Possible values: 1: The current state could not be determined. 2: The battery is operating normally. 3: The battery has failed and needs to be replaced. 4: The battery temperature is high or charge level is depleting. 5: The battery is missing or not detected. 6: The battery is undergoing the re-charge phase. 7: The battery voltage or charge level is below the threshold. |
SNMP agent | dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}] Preprocessing
|
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
DELL PowerEdge R840: {#BATTERY_NAME} is in critical state | Please check the device for faults. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT} |
Average | |
DELL PowerEdge R840: {#BATTERY_NAME} is in warning state | Please check the device for faults. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN} |
Warning | Depends on:
|
DELL PowerEdge R840: {#BATTERY_NAME} is not in optimal state | Please check the device for faults. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK} |
Warning | Depends on:
|
Name | Description | Type | Key and additional info |
---|---|---|---|
Physical disk discovery | Scanning table of physical drive entries IDRAC-MIB-SMIv2::physicalDiskTable. |
SNMP agent | physicaldisk.discovery Preprocessing
|
Name | Description | Type | Key and additional info |
---|---|---|---|
{#DISK_NAME} Status | MIB: IDRAC-MIB-SMIv2 The status of the physical disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable |
SNMP agent | dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}] Preprocessing
|
{#DISK_NAME} S.M.A.R.T. Status | MIB: IDRAC-MIB-SMIv2 Indicates whether the physical disk has received a predictive failure alert. |
SNMP agent | dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}] Preprocessing
|
{#DISK_NAME} Serial number | MIB: IDRAC-MIB-SMIv2 The physical disk's unique identification number from the manufacturer. |
SNMP agent | dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}] Preprocessing
|
{#DISK_NAME} Model name | MIB: IDRAC-MIB-SMIv2 The model number of the physical disk. |
SNMP agent | dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}] Preprocessing
|
{#DISK_NAME} Media type | MIB: IDRAC-MIB-SMIv2 The media type of the physical disk. Possible Values: 1: The media type could not be determined. 2: Hard Disk Drive (HDD). 3: Solid State Drive (SSD). |
SNMP agent | dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}] Preprocessing
|
{#DISK_NAME} Size | MIB: IDRAC-MIB-SMIv2 The size of the physical disk in megabytes. |
SNMP agent | dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}] Preprocessing
|
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
DELL PowerEdge R840: {#DISK_NAME} failed | Please check physical disk for warnings or errors. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"nonRecoverable"} |
High | |
DELL PowerEdge R840: {#DISK_NAME} is in warning state | Please check physical disk for warnings or errors. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.WARN:"nonCritical"} |
Warning | Depends on:
|
DELL PowerEdge R840: {#DISK_NAME} S.M.A.R.T. failed | Disk probably requires replacement. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"} |
High | Depends on:
|
DELL PowerEdge R840: {#DISK_NAME} has been replaced | {#DISK_NAME} serial number has changed. Acknowledge to close the problem manually. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0 |
Info | Manual close: Yes |
Name | Description | Type | Key and additional info |
---|---|---|---|
Virtual disk discovery | IDRAC-MIB-SMIv2::virtualDiskTable |
SNMP agent | virtualdisk.discovery Preprocessing
|
Name | Description | Type | Key and additional info |
---|---|---|---|
{#DISK_NAME} Status | MIB: IDRAC-MIB-SMIv2 The current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost. 4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant. |
SNMP agent | dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}] Preprocessing
|
{#DISK_NAME} Layout type | MIB: IDRAC-MIB-SMIv2 The virtual disk's RAID type. Possible values: 1: Not one of the following 2: RAID-0 3: RAID-1 4: RAID-5 5: RAID-6 6: RAID-10 7: RAID-50 8: RAID-60 9: Concatenated RAID 1 10: Concatenated RAID 5 |
SNMP agent | dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}] Preprocessing
|
{#DISK_NAME} Size | MIB: IDRAC-MIB-SMIv2 The size of the virtual disk in megabytes. |
SNMP agent | dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}] Preprocessing
|
{#DISK_NAME} Current state | MIB: IDRAC-MIB-SMIv2 The state of the virtual disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration. 3: A Consistency Check (CC) is being performed on the virtual disk. 4: The virtual disk is being initialized. 5: BackGround Initialization (BGI) is being performed on the virtual disk. |
SNMP agent | dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}] |
{#DISK_NAME} Read policy | MIB: IDRAC-MIB-SMIv2 The read policy used by the controller for read operations on this virtual disk. Possible values: 1: No Read Ahead. 2: Read Ahead. 3: Adaptive Read Ahead. |
SNMP agent | dell.server.hw.virtualdisk.readpolicy[virtualDiskReadPolicy.{#SNMPINDEX}] |
{#DISK_NAME} Write policy | MIB: IDRAC-MIB-SMIv2 The write policy used by the controller for write operations on this virtual disk. Possible values: 1: Write Through. 2: Write Back. 3: Force Write Back. |
SNMP agent | dell.server.hw.virtualdisk.writepolicy[virtualDiskWritePolicy.{#SNMPINDEX}] |
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
DELL PowerEdge R840: {#DISK_NAME} failed | Please check the virtual disk for warnings or errors. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.CRIT:"failed"} |
High | |
DELL PowerEdge R840: {#DISK_NAME} is in warning state | Please check the virtual disk for warnings or errors. |
last(/DELL PowerEdge R840 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.WARN:"degraded"} |
Average | Depends on:
|
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums