Source: https://git.zabbix.com/projects/ZBX/repos/zabbix/browse/templates/server/dell/dell_r820_snmp

DELL PowerEdge R820 SNMP

Overview

For Zabbix version: 6.4 and higher
This is a template for monitoring DELL PowerEdge R820 servers with iDRAC version 7 and later via Zabbix SNMP agent that works without any external scripts.

Setup

See Zabbix template operation for basic instructions.

Refer to the vendor documentation.

Zabbix configuration

No specific Zabbix configuration is required.

Macros used

Name Description Default
{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}

The critical status of the disk array cache battery for trigger expression.

3
{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}

The OK status of the disk array cache battery for trigger expression.

2
{$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}

The warning status of the disk array cache battery for trigger expression.

4
{$DISK.ARRAY.STATUS.CRIT}

The critical status of the disk array for trigger expression.

5
{$DISK.ARRAY.STATUS.FAIL}

The disaster status of the disk array for trigger expression.

6
{$DISK.ARRAY.STATUS.WARN}

The warning status of the disk array for trigger expression.

4
{$DISK.SMART.STATUS.FAIL}

The critical S.M.A.R.T status of the disk for trigger expression.

1
{$DISK.STATUS.FAIL:"critical"}

The critical status of the disk for trigger expression.

5
{$DISK.STATUS.FAIL:"nonRecoverable"}

The critical status of the disk for trigger expression.

6
{$DISK.STATUS.WARN:"nonCritical"}

The warning status of the disk for trigger expression.

4
{$FAN.STATUS.CRIT:"criticalLower"}

The critical value of the FAN sensor for trigger expression.

8
{$FAN.STATUS.CRIT:"criticalUpper"}

The critical value of the FAN sensor for trigger expression.

5
{$FAN.STATUS.CRIT:"failed"}

The critical value of the FAN sensor for trigger expression.

10
{$FAN.STATUS.CRIT:"nonRecoverableLower"}

The critical value of the FAN sensor for trigger expression.

9
{$FAN.STATUS.CRIT:"nonRecoverableUpper"}

The critical value of the FAN sensor for trigger expression.

6
{$FAN.STATUS.WARN:"nonCriticalLower"}

The warning value of the FAN sensor for trigger expression.

7
{$FAN.STATUS.WARN:"nonCriticalUpper"}

The warning value of the FAN sensor for trigger expression.

4
{$HEALTH.STATUS.CRIT}

The critical status of the health for trigger expression.

5
{$HEALTH.STATUS.DISASTER}

The disaster status of the health for trigger expression.

6
{$HEALTH.STATUS.WARN}

The warning status of the health for trigger expression.

4
{$PSU.STATUS.CRIT:"critical"}

The critical value of the PSU sensor for trigger expression.

5
{$PSU.STATUS.CRIT:"nonRecoverable"}

The critical value of the PSU sensor for trigger expression.

6
{$PSU.STATUS.WARN:"nonCritical"}

The warning value of the PSU sensor for trigger expression.

4
{$SENSOR.TEMP.STATUS.CRIT:"criticalLower"}

The critical status of the temperature probe for trigger expression.

8
{$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}

The critical status of the temperature probe for trigger expression.

5
{$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}

The critical status of the temperature probe for trigger expression.

9
{$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}

The critical status of the temperature probe for trigger expression.

6
{$SENSOR.TEMP.STATUS.OK}

The OK status of the temperature probe for trigger expression.

3
{$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}

The warning status of the temperature probe for trigger expression.

7
{$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}

The warning status of the temperature probe for trigger expression.

4
{$SNMP.TIMEOUT}

The time interval for SNMP agent availability trigger expression.

5m
{$VDISK.STATUS.CRIT:"failed"}

The critical status of the virtual disk for trigger expression.

3
{$VDISK.STATUS.WARN:"degraded"}

The warning status of the virtual disk for trigger expression.

4

Template links

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
Array controller cache discovery

Scanning table of Array controllers: IDRAC-MIB-SMIv2::batteryTable

SNMP array.cache.discovery

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Array controller discovery

Scanning table of Array controllers: IDRAC-MIB-SMIv2::controllerTable

SNMP array.discovery

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

FAN discovery

IDRAC-MIB-SMIv2::coolingDeviceTable

SNMP fan.discovery

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Filter:

AND_OR

- {#TYPE} MATCHES_REGEX 3

Physical disk discovery

Scanning table of physical drive entries IDRAC-MIB-SMIv2::physicalDiskTable.

SNMP physicaldisk.discovery

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

PSU discovery

IDRAC-MIB-SMIv2::powerSupplyTable

SNMP psu.discovery

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Temperature discovery

Scanning table of Temperature Probe Table IDRAC-MIB-SMIv2::temperatureProbeTable

SNMP temp.discovery

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Virtual disk discovery

IDRAC-MIB-SMIv2::virtualDiskTable

SNMP virtualdisk.discovery

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Items collected

Group Name Description Type Key and additional info
Disk arrays Dell R820: {#CNTLR_NAME} Status

MIB: IDRAC-MIB-SMIv2

The status of the controller itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

SNMP dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Disk arrays Dell R820: {#CNTLR_NAME} Model

MIB: IDRAC-MIB-SMIv2

The controller's name as represented in Storage Management.

SNMP dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Disk arrays Dell R820: {#BATTERY_NAME} Status

MIB: IDRAC-MIB-SMIv2

Current state of battery.

Possible values:

1: The current state could not be determined.

2: The battery is operating normally.

3: The battery has failed and needs to be replaced.

4: The battery temperature is high or charge level is depleting.

5: The battery is missing or not detected.

6: The battery is undergoing the re-charge phase.

7: The battery voltage or charge level is below the threshold.

SNMP dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Fans Dell R820: {#FAN_DESCR} Status

MIB: IDRAC-MIB-SMIv2

This attribute defines the probe status of the cooling device.

SNMP dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Fans Dell R820: {#FAN_DESCR} Speed

MIB: IDRAC-MIB-SMIv2

This attribute defines the reading for a cooling device

of subtype other than coolingDeviceSubTypeIsDiscrete. When the value

for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the

value returned for this attribute is the speed in RPM or the OFF/ON value

of the cooling device. When the value for coolingDeviceSubType is

coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute.

SNMP dell.server.sensor.fan.speed[coolingDeviceReading.{#SNMPINDEX}]
General Dell R820: SNMP traps (fallback)

The item is used to collect all SNMP traps unmatched by other snmptrap items

SNMP_TRAP snmptrap.fallback
General Dell R820: System location

MIB: SNMPv2-MIB

The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.

SNMP dell.server.location[sysLocation]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

General Dell R820: System contact details

MIB: SNMPv2-MIB

The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.

SNMP dell.server.contact[sysContact]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 1d

General Dell R820: System object ID

MIB: SNMPv2-MIB

The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining 'what kind of box' is being managed. For example, if vendor 'Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its 'Fred Router'.

SNMP dell.server.objectid[sysObjectID]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

General Dell R820: System name

MIB: SNMPv2-MIB

An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.

SNMP dell.server.name[sysName]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

General Dell R820: System description

MIB: SNMPv2-MIB

A textual description of the entity. This value should

include the full name and version identification of the system's hardware type, software operating-system, and

networking software.

SNMP dell.server.descr[sysDescr]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 1d

Inventory Dell R820: Hardware model name

MIB: IDRAC-MIB-SMIv2

This attribute defines the model name of the system.

SNMP dell.server.hw.model[systemModelName]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Inventory Dell R820: Hardware serial number

MIB: IDRAC-MIB-SMIv2

This attribute defines the service tag of the system.

SNMP dell.server.hw.serialnumber[systemServiceTag]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Inventory Dell R820: Operating system

MIB: IDRAC-MIB-SMIv2

This attribute defines the name of the operating system that the host is running.

SNMP dell.server.sw.os[systemOSName]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 1d

Inventory Dell R820: Firmware version

MIB: IDRAC-MIB-SMIv2

This attribute defines the firmware version of a remote access card.

SNMP dell.server.hw.firmware[racFirmwareVersion]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 1d

Physical disks Dell R820: {#DISK_NAME} Status

MIB: IDRAC-MIB-SMIv2

The status of the physical disk itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

SNMP dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Physical disks Dell R820: {#DISK_NAME} S.M.A.R.T. Status

MIB: IDRAC-MIB-SMIv2

Indicates whether the physical disk has received a predictive failure alert.

SNMP dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Physical disks Dell R820: {#DISK_NAME} Serial number

MIB: IDRAC-MIB-SMIv2

The physical disk's unique identification number from the manufacturer.

SNMP dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Physical disks Dell R820: {#DISK_NAME} Model name

MIB: IDRAC-MIB-SMIv2

The model number of the physical disk.

SNMP dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Physical disks Dell R820: {#DISK_NAME} Media type

MIB: IDRAC-MIB-SMIv2

The media type of the physical disk. Possible Values:

1: The media type could not be determined.

2: Hard Disk Drive (HDD).

3: Solid State Drive (SSD).

SNMP dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Physical disks Dell R820: {#DISK_NAME} Size

MIB: IDRAC-MIB-SMIv2

The size of the physical disk in megabytes.

SNMP dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]

Preprocessing:

- MULTIPLIER: 1048576

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Power supply Dell R820: {#PSU_DESCR}

MIB: IDRAC-MIB-SMIv2

0600.0012.0001.0005 This attribute defines the status of the power supply.

SNMP dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Status Dell R820: Overall system health status

MIB: IDRAC-MIB-SMIv2

This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc.

SNMP dell.server.status[globalSystemStatus]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Status Dell R820: Uptime (network)

MIB: SNMPv2-MIB

The time (in hundredths of a second) since the network management portion of the system was last re-initialized.

SNMP dell.server.net.uptime[sysUpTime]

Preprocessing:

- MULTIPLIER: 0.01

Status Dell R820: Uptime (hardware)

MIB: HOST-RESOURCES-MIB

The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.

SNMP dell.server.hw.uptime[hrSystemUptime]

Preprocessing:

- CHECK_NOT_SUPPORTED

⛔️ON_FAIL: CUSTOM_VALUE -> 0

- MULTIPLIER: 0.01

Status Dell R820: SNMP agent availability

-

INTERNAL zabbix[host,snmp,available]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Temperature Dell R820: {#SENSOR_LOCALE} Value

MIB: IDRAC-MIB-SMIv2

This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the value returned for this attribute is the temperature that the probe is reading in Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute.

SNMP dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]

Preprocessing:

- MULTIPLIER: 0.1

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Temperature Dell R820: {#SENSOR_LOCALE} Status

MIB: IDRAC-MIB-SMIv2

This attribute defines the probe status of the temperature probe.

Possible values:

other(1), -- probe status is not one of the following:

unknown(2), -- probe status is unknown (not known or monitored)

ok(3), -- probe is reporting a value within the thresholds

nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold

criticalUpper(5), -- probe has crossed the upper critical threshold

nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold

nonCriticalLower(7), -- probe has crossed the lower noncritical threshold

criticalLower(8), -- probe has crossed the lower critical threshold

nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold

failed(10) -- probe is not functional

SNMP dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Virtual disks Dell R820: {#DISK_NAME} Status

MIB: IDRAC-MIB-SMIv2

The current state of this virtual disk (which includes any member physical disks.)

Possible states:

1: The current state could not be determined.

2: The virtual disk is operating normally or optimally.

3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost.

4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks.

The data on the virtual disk might no longer be fault tolerant.

SNMP dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Virtual disks Dell R820: {#DISK_NAME} Layout type

MIB: IDRAC-MIB-SMIv2

The virtual disk's RAID type.

Possible values:

1: Not one of the following

2: RAID-0

3: RAID-1

4: RAID-5

5: RAID-6

6: RAID-10

7: RAID-50

8: RAID-60

9: Concatenated RAID 1

10: Concatenated RAID 5

SNMP dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]

Preprocessing:

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Virtual disks Dell R820: {#DISK_NAME} Size

MIB: IDRAC-MIB-SMIv2

The size of the virtual disk in megabytes.

SNMP dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]

Preprocessing:

- MULTIPLIER: 1048576

- DISCARD_UNCHANGED_HEARTBEAT: 6h

Virtual disks Dell R820: {#DISK_NAME} Current state

MIB: IDRAC-MIB-SMIv2

The state of the virtual disk when there are progressive operations ongoing.

Possible values:

1: There is no active operation running.

2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration.

3: A Consistency Check (CC) is being performed on the virtual disk.

4: The virtual disk is being initialized.

5: BackGround Initialization (BGI) is being performed on the virtual disk.

SNMP dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]
Virtual disks Dell R820: {#DISK_NAME} Read policy

MIB: IDRAC-MIB-SMIv2

The read policy used by the controller for read operations on this virtual disk.

Possible values:

1: No Read Ahead.

2: Read Ahead.

3: Adaptive Read Ahead.

SNMP dell.server.hw.virtualdisk.readpolicy[virtualDiskReadPolicy.{#SNMPINDEX}]
Virtual disks Dell R820: {#DISK_NAME} Write policy

MIB: IDRAC-MIB-SMIv2

The write policy used by the controller for write operations on this virtual disk.

Possible values:

1: Write Through.

2: Write Back.

3: Force Write Back.

SNMP dell.server.hw.virtualdisk.writepolicy[virtualDiskWritePolicy.{#SNMPINDEX}]

Triggers

Name Description Expression Severity Dependencies and additional info
Dell R820: {#CNTLR_NAME} is in unrecoverable state

Please check the device for faults.

last(/DELL PowerEdge R820 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.FAIL} DISASTER
Dell R820: {#CNTLR_NAME} is in critical state

Please check the device for faults.

last(/DELL PowerEdge R820 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT} HIGH

Depends on:

- Dell R820: {#CNTLR_NAME} is in unrecoverable state

Dell R820: {#CNTLR_NAME} is in warning state

Please check the device for faults.

last(/DELL PowerEdge R820 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN} AVERAGE

Depends on:

- Dell R820: {#CNTLR_NAME} is in critical state

- Dell R820: {#CNTLR_NAME} is in unrecoverable state

Dell R820: {#BATTERY_NAME} is in critical state

Please check the device for faults.

last(/DELL PowerEdge R820 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT} AVERAGE
Dell R820: {#BATTERY_NAME} is in warning state

Please check the device for faults.

last(/DELL PowerEdge R820 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN} WARNING

Depends on:

- Dell R820: {#BATTERY_NAME} is in critical state

Dell R820: {#BATTERY_NAME} is not in optimal state

Please check the device for faults.

last(/DELL PowerEdge R820 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK} WARNING

Depends on:

- Dell R820: {#BATTERY_NAME} is in critical state

- Dell R820: {#BATTERY_NAME} is in warning state

Dell R820: {#FAN_DESCR} is in critical state

Please check the fan unit.

last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"failed"} AVERAGE
Dell R820: {#FAN_DESCR} is in warning state

Please check the fan unit.

last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalLower"} WARNING

Depends on:

- Dell R820: {#FAN_DESCR} is in critical state

Dell R820: System name has changed

System name has changed. Ack to close.

last(/DELL PowerEdge R820 SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R820 SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R820 SNMP/dell.server.name[sysName]))>0 INFO

Manual close: YES

Dell R820: Device has been replaced

Device serial number has changed. Ack to close

last(/DELL PowerEdge R820 SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R820 SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R820 SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0 INFO

Manual close: YES

Dell R820: Operating system description has changed

Operating system description has changed. Possibly, the system has been updated or replaced. Ack to close.

last(/DELL PowerEdge R820 SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R820 SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R820 SNMP/dell.server.sw.os[systemOSName]))>0 INFO

Manual close: YES

Dell R820: Firmware has changed

Firmware version has changed. Ack to close.

last(/DELL PowerEdge R820 SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R820 SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R820 SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0 INFO

Manual close: YES

Dell R820: {#DISK_NAME} failed

Please check physical disk for warnings or errors.

last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"nonRecoverable"} HIGH
Dell R820: {#DISK_NAME} is in warning state

Please check physical disk for warnings or errors.

last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.WARN:"nonCritical"} WARNING

Depends on:

- Dell R820: {#DISK_NAME} failed

Dell R820: {#DISK_NAME} S.M.A.R.T. failed

Disk probably requires replacement.

last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"} HIGH

Depends on:

- Dell R820: {#DISK_NAME} failed

Dell R820: {#DISK_NAME} has been replaced

{#DISK_NAME} serial number has changed. Ack to close

last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0 INFO

Manual close: YES

Dell R820: Power supply {#PSU_DESCR} is in critical state

Please check the power supply unit for errors.

last(/DELL PowerEdge R820 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"nonRecoverable"} AVERAGE
Dell R820: Power supply {#PSU_DESCR} is in warning state

Please check the power supply unit for errors.

last(/DELL PowerEdge R820 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.WARN:"nonCritical"} WARNING

Depends on:

- Dell R820: Power supply {#PSU_DESCR} is in critical state

Dell R820: System is in unrecoverable state

Please check the device for faults.

last(/DELL PowerEdge R820 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.DISASTER} DISASTER
Dell R820: System status is in critical state

Please check the device for errors.

last(/DELL PowerEdge R820 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.CRIT} HIGH
Dell R820: System status is in warning state

Please check the device for warnings.

last(/DELL PowerEdge R820 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.WARN} WARNING

Depends on:

- Dell R820: System status is in critical state

Dell R820: Host has been restarted

Uptime is less than 10 minutes.

(last(/DELL PowerEdge R820 SNMP/dell.server.hw.uptime[hrSystemUptime])>0 and last(/DELL PowerEdge R820 SNMP/dell.server.hw.uptime[hrSystemUptime])<10m) or (last(/DELL PowerEdge R820 SNMP/dell.server.hw.uptime[hrSystemUptime])=0 and last(/DELL PowerEdge R820 SNMP/dell.server.net.uptime[sysUpTime])<10m) WARNING

Manual close: YES

Dell R820: No SNMP data collection

SNMP is not available for polling. Please check device connectivity and SNMP settings.

max(/DELL PowerEdge R820 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 WARNING
Dell R820: Probe {#SENSOR_LOCALE} is in critical status

Please check the device for faults.

last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"} AVERAGE
Dell R820: Probe {#SENSOR_LOCALE} is in warning status

Please check the device for faults.

last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"} WARNING

Depends on:

- Dell R820: Probe {#SENSOR_LOCALE} is in critical status

Dell R820: Probe {#SENSOR_LOCALE} is not in optimal status

Please check the device for faults.

last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$SENSOR.TEMP.STATUS.OK} INFO

Manual close: YES

Depends on:

- Dell R820: Probe {#SENSOR_LOCALE} is in critical status

- Dell R820: Probe {#SENSOR_LOCALE} is in warning status

Dell R820: {#DISK_NAME} failed

Please check the virtual disk for warnings or errors.

last(/DELL PowerEdge R820 SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.CRIT:"failed"} HIGH
Dell R820: {#DISK_NAME} is in warning state

Please check the virtual disk for warnings or errors.

last(/DELL PowerEdge R820 SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.WARN:"degraded"} AVERAGE

Depends on:

- Dell R820: {#DISK_NAME} failed

Feedback

Please report any issues with the template at https://support.zabbix.com

You can also provide feedback, discuss the template or ask for help with it at ZABBIX forums.

Articles and documentation

+ Propose new article

Didn't find integration you need?