Sidebar

manual:maintenance

11. Maintenance

Overview

You can define maintenance periods for host groups, hosts and specific triggers/services in Zabbix.

There are two maintenance types - with data collection and with no data collection.

During a maintenance “with data collection” triggers are processed as usual and events are created when required. However, problem escalations are paused for hosts/triggers in maintenance, if the Pause operations for suppressed problems option is checked in action configuration. In this case, escalation steps that may include sending notifications or remote commands will be ignored for as long as the maintenance period lasts.

For example, if escalation steps are scheduled at 0, 30 and 60 minutes after a problem start, and there is a half-hour long maintenance lasting from 10 minutes to 40 minutes after a real problem arises, steps two and three will be executed a half-hour later, or at 60 minutes and 90 minutes (providing the problem still exists). Similarly, if a problem arises during the maintenance, the escalation will start after the maintenance.

To receive problem notifications during the maintenance normally (without delay), you have to uncheck the Pause operations for suppressed problems option in action configuration.

If at least one host (used in the trigger expression) is not in maintenance mode, Zabbix will send a problem notification.

Zabbix server must be running during maintenance. Timer processes are responsible for switching host status to/from maintenance at 0 seconds of every minute. Note that when a host enters maintenance, Zabbix server timer processes will read all open problems to check if it is required to suppress those. This may have a performance impact if there are many open problems. Zabbix server will also read all open problems upon startup, even if there are no maintenances configured at the time.

A proxy will always collect data regardless of the maintenance type (including “no data” maintenance). The data is later ignored by the server if 'no data collection' is set.

When “no data” maintenance ends, triggers using nodata() function will not fire before the next check during the period they are checking.

If a log item is added while a host is in maintenance and the maintenance ends, only new logfile entries since the end of the maintenance will be gathered.

If a timestamped value is sent for a host that is in a “no data” maintenance type (e.g. using Zabbix sender) then this value will be dropped however it is possible to send a timestamped value in for an expired maintenance period and it will be accepted.

To ensure predictable behaviour of recurring maintenance periods (daily, weekly, monthly), it is required to use a common time zone for all parts of Zabbix.

If maintenance period, hosts, groups or tags are changed by the user, the changes will only take effect after configuration cache synchronization.

Configuration

To configure a maintenance period:

  • Go to: Configuration → Maintenance
  • Click on Create maintenance period (or on the name of an existing maintenance period)

Fill out the Maintenance periods configuration form:

All mandatory input fields are marked with a red asterisk.

ParameterDescription
Name Name of the maintenance period.
Maintenance type Two types of maintenance can be set:
With data collection - data will be collected by the server during maintenance, triggers will be processed
No data collection - data will not be collected by the server during maintenance
Active since The date and time when executing maintenance periods becomes active.
Note: Setting this time alone does not activate a maintenance period; for that go to the Periods tab.
Active till The date and time when executing maintenance periods stops being active.
Periods This block allows you to define the exact days and hours when the maintenance takes place. Clicking on opens a popup window with a flexible Maintenance period form where you can define maintenance schedule. See Maintenance periods for a detailed description.
Host groups Select host groups that the maintenance will be activated for. The maintenance will be activated for all hosts from the specified host group(s). This field is auto-complete, so starting to type in it will display a dropdown of all available host groups.
Specifying a parent host group implicitly selects all nested host groups. Thus the maintenance will also be activated on hosts from nested groups.
Hosts Select hosts that the maintenance will be activated for. This field is auto-complete, so starting to type in it will display a dropdown of all available hosts.
Tags If maintenance tags are specified, maintenance for the selected hosts will still be activated, but problems will only be suppressed (i.e. no actions will be taken) if their tags are a match.
In case of multiple tags, they are calculated as follows:
And/Or - all tags must correspond; however tags with the same tag name are calculated by the Or condition
Or - enough if one tag corresponds
There are two ways of matching the tag value:
Contains - case-sensitive substring match (tag value contains the entered string)
Equals - case-sensitive string match (tag value equals the entered string)
Description Description of maintenance period.
Maintenance periods

The maintenance period window is for scheduling time for a recurring or a one-time maintenance. The form is dynamic with available fields changing based on the Period type selected.

Period type
One time only Define the date and time, and the length of the maintenance period.
Daily Every day(s) - maintenance frequency: 1 (default) - every day, 2 - every two days, etc.
At (hour:minute) - time of the day when maintenance starts
Maintenance period length - for how long the maintenance will be active.
Weekly Every week(s) - maintenance frequency: 1 (default) - every day, 2 - every two days, etc.
Day of week - on which day the maintenance should take place.
At (hour:minute) - time of the day when maintenance starts
Maintenance period length - for how long the maintenance will be active.
Monthly