Šajā lapā
SNMP template operation
In addition to network devices, SNMP templates are available for servers, power devices, storage systems, operating systems and applications.
Steps to ensure correct operation of templates that collect metrics using SNMP agent items:
- Enable SNMP on the monitored device, operating system or application.
- Create a host in Zabbix with an SNMP interface pointing to the monitored target.
- Link the template to the host (if the template is not available in your Zabbix installation, you may need to import the template first).
- Set the SNMP community or SNMPv3 credentials, and adjust other template macros if necessary.
A detailed description of a template, including the full list of macros, items and triggers, is available in the template's README file (accessible by clicking a template name).
The following templates are available:
Server hardware
| Template name | Vendor | Device family | Known models | OS | MIBs used | Tags |
|---|---|---|---|---|---|---|
| Cisco UCS by SNMP | Cisco | UCS Rack Servers | UCS C240 M4SX | Cisco CIMC firmware | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB, CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB, CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB, CISCO-UNIFIED-COMPUTING-STORAGE-MIB | Fault Inventory |
| Cisco UCS Manager by SNMP | Cisco | UCS Data Center Infrastructure | UCS B-Series, C-Series, Fabric Interconnects |
Cisco UCS Manager | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB, CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB, CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB, CISCO-UNIFIED-COMPUTING-STORAGE-MIB | Fault Inventory |
| Dell iDRAC by SNMP | Dell Technologies | PowerEdge Servers/iDRAC | PowerEdge R620, PowerEdge R720, PowerEdge R730xd, PowerEdge R660xs, PowerEdge R750xs |
Dell iDRAC firmware | IDRAC-MIB-SMIv2, SNMPv2-MIB, SNMP-FRAMEWORK-MIB | Fault Inventory |
| DELL PowerEdge <device model> by SNMP | Dell | DELL PowerEdge servers (iDRAC 7 and later) | Each model has its own template: DELL PowerEdge R660, DELL PowerEdge R720, DELL PowerEdge R740, DELL PowerEdge R750, DELL PowerEdge R820, DELL PowerEdge R840 |
- | IDRAC-MIB-SMIv2, SNMPv2-MIB, SNMP-FRAMEWORK-MIB | Fault Inventory |
| HP iLO by SNMP | HP | HP ProLiant servers (iLO) | HP ProLiant G9 (iLO 4) | - | CPQSINFO-MIB, CPQHLTH-MIB, CPQIDA-MIB, HOST-RESOURCES-MIB, SNMPv2-MIB | Fault Inventory |
| HPE ProLiant <device model> by SNMP | HPE | HPE ProLiant servers (iLO 4 and later) | Each model has its own template: HPE ProLiant BL460, HPE ProLiant BL920, HPE ProLiant DL360, HPE ProLiant DL380 |
- | CPQSINFO-MIB, CPQHLTH-MIB, CPQIDA-MIB, CPQNIC-MIB, HOST-RESOURCES-MIB, SNMPv2-MIB | Fault Inventory |
| IBM IMM by SNMP | IBM | IBM System x servers (IMM1, IMM2) | IBM System x3250 M3, IBM System x3550 M2, IBM System x3550 M3, IBM System x3550 M5 |
- | IMM-MIB, HOST-RESOURCES-MIB, SNMPv2-MIB | Fault Inventory |
| Supermicro Aten by SNMP | Supermicro | Supermicro servers (ATEN IPMI BMC) | Supermicro X10DRi | - | ATEN-IPMI-MIB, HOST-RESOURCES-MIB, SNMPv2-MIB | Fault |
Power devices
| Template name | Vendor | Device family | Known models | OS | MIBs used | Tags |
|---|---|---|---|---|---|---|
| APC Smart-UPS <device model> by SNMP | APC/Schneider Electric | Smart-UPS | Each model has its own template: APC Smart-UPS 2200 RM, APC Smart-UPS 3000 XLM |
Embedded UPS/NMC firmware | PowerNet-MIB, SNMPv2-MIB | Fault Inventory |
| APC Smart-UPS RT <device model> by SNMP | APC/Schneider Electric | Smart-UPS | Each model has its own template: APC Smart-UPS RT 1000 RM XL, APC Smart-UPS RT 1000 XL |
Embedded UPS/NMC firmware | PowerNet-MIB, SNMPv2-MIB | Fault Inventory |
| APC Smart-UPS SRT <device model> by SNMP | APC/Schneider Electric | Smart-UPS | Each model has its own template: APC Smart-UPS SRT 5000, APC Smart-UPS SRT 8000 |
Embedded UPS/NMC firmware | PowerNet-MIB, SNMPv2-MIB | Fault Inventory |
| APC UPS by SNMP | APC/Schneider Electric | General APC UPS | APC UPS with Network Management Card (NMC); various models | Embedded UPS/NMC firmware | PowerNet-MIB, SNMPv2-MIB | Fault Inventory |
| APC UPS Galaxy 3500 by SNMP | APC/Schneider Electric | Galaxy | Galaxy 3500 | Embedded UPS/NMC firmware | PowerNet-MIB, SNMPv2-MIB | Fault Inventory |
| APC UPS Symmetra <device model> by SNMP | APC/Schneider Electric | Symmetra | Each model has its own template: APC UPS Symmetra LX, APC UPS Symmetra RM, APC UPS Symmetra RX |
Embedded UPS/NMC firmware | PowerNet-MIB, SNMPv2-MIB | Fault Inventory |
| Morningstar ProStar <device model> by SNMP | Morningstar | Solar charge controllers | Each model has its own template: Morningstar ProStar MPPT, Morningstar ProStar PWM |
- | PROSTAR-MPPT, PROSTAR-PWM, HOST-RESOURCES-MIB, SNMPv2-MIB | Fault |
| Morningstar SunSaver MPPT by SNMP | Morningstar | Solar charge controllers | Morningstar SunSaver MPPT | - | SUNSAVER-MPPT, HOST-RESOURCES-MIB, SNMPv2-MIB | Fault |
| Morningstar SureSine by SNMP | Morningstar | Inverters | Morningstar SureSine | - | SURESINE, HOST-RESOURCES-MIB, SNMPv2-MIB | Fault |
| Morningstar TriStar <device model> by SNMP | Morningstar | Solar charge controllers | Each model has its own template: Morningstar TriStar MPPT, Morningstar TriStar MPPT 600V, Morningstar TriStar PWM |
- | TRISTAR, TRISTAR-MPPT, HOST-RESOURCES-MIB, SNMPv2-MIB | Fault |
Storage
| Template name | Vendor | Device family | Known models | OS | MIBs used | Tags |
|---|---|---|---|---|---|---|
| Huawei OceanStor 5300 V5 by SNMP | Huawei | Huawei OceanStor | Huawei OceanStor 5300 V5 | - | HUAWEI-STORAGE-HARDWARE-MIB, HUAWEI-STORAGE-SPACE-MIB, ISM-PERFORMANCE-MIB, HOST-RESOURCES-MIB, SNMPv2-MIB | Certified |
| Huawei OceanStor Dorado by SNMP | Huawei | Huawei OceanStor, Huawei OceanStor Dorado | Huawei OceanStor Dorado 3000/5000/6000/8000/18000/5300/5500/5600/6800/18500/18800 with V6/V700 software | - | HUAWEI-STORAGE-HARDWARE-MIB, HUAWEI-STORAGE-SPACE-MIB, ISM-PERFORMANCE-MIB, HOST-RESOURCES-MIB, SNMPv2-MIB | Certified |
| NetApp FAS3220 by SNMP | NetApp | NetApp FAS storage | NetApp FAS3220 | ONTAP | NETAPP-MIB, HOST-RESOURCES-MIB, SNMPv2-MIB | Fault Inventory |
Operating systems and applications
| Template name | Vendor | Device family | Known models | OS | MIBs used | Tags |
|---|---|---|---|---|---|---|
| Linux by SNMP | - | Linux servers | - | Linux | EtherLike-MIB, HOST-RESOURCES-MIB, IF-MIB, SNMPv2-MIB, UCD-DISKIO-MIB, UCD-SNMP-MIB | Performance |
| OPNsense by SNMP | OPNsense | OPNsense firewall | - | OPNsense | BEGEMOT-PF-MIB, HOST-RESOURCES-MIB, IF-MIB | - |
| PFSense by SNMP | Netgate | pfSense firewall | - | pfSense | BEGEMOT-PF-MIB, HOST-RESOURCES-MIB, IF-MIB | - |
| Squid by SNMP | Squid | Squid caching proxy | - | - | SQUID-MIB | Performance |
| TrueNAS CORE by SNMP | iXsystems | TrueNAS CORE storage | - | TrueNAS CORE | FREENAS-MIB, HOST-RESOURCES-MIB, IF-MIB, SNMPv2-MIB, UCD-DISKIO-MIB, UCD-SNMP-MIB | Performance Fault |
| Windows by SNMP | - | Windows servers | - | Windows | HOST-RESOURCES-MIB, IF-MIB, SNMPv2-MIB | Performance |